• MCS-certified products
  • Next Day Delivery
SolaX OUT OF STOCK

SolaX X3 G4-V2 Hybrid 3 Phase Inverter HV 8.0kW

X3-HYBRIDPRO-G4-8.0
£1,169.61 ex VAT £1,403.53 inc VAT

How many inverters do you need?

Secure Checkout 14-Day Returns Tracked Delivery
High Conversion EfficiencyMore of your solar reaches the home
MPPT TrackingMaximises yield in changing light
Grid CompliantMeets UK G98 / G99 requirements
Technical Specifications
Rated Power (Pmax)8,000 W
Module Efficiency98.0 %
Battery Voltage120 - 800 V
MPPT Quantity3
Min MPPT Voltage110 V
Max MPPT Voltage950 V
Max Input Voltage950 V
Max DC Power16 kWp
Max AC Power (5 min)8,800 VA
Max DC Current20 A / 20 A / 20 A
Max DC Inputs3
Integrated DC SwitchYes
Height503 mm
Width560 mm
Depth210 mm
Weight38 kg
IP RatingIP66
Operating Temperature-35 °C to +60 °C, derating above +45 °C
View Full Datasheet

SolaX X3 G4-V2 Hybrid 3 Phase Inverter HV 8.0kW

SolaX · X3-Hybrid Pro G4

SolaX X3 G4-V2 Hybrid 3 Phase Inverter HV 8.0kW

SolaX X3-Hybrid Pro G4 — Three trackers, two battery ports and 200 % EPS for ten seconds, in an IP66 case.

A hybrid inverter does three jobs a string inverter cannot. It converts solar DC to AC; it charges and discharges a battery on the DC side, which avoids the double conversion an AC-coupled battery pays for; and when the grid fails it islands the house and keeps the EPS output alive from the battery.

Rated AC output
8,000 WThree phase on-grid output
Backup output
8 kVAContinuous EPS power in a grid outage
Maximum PV input
16 kWpArray size this inverter accepts
Battery window
120 – 800 VThe architecture it takes
MPP trackers
3Independent roof planes
Peak efficiency
98.0 %Conversion efficiency at best
Backup switch time
<10 msHow fast it takes over
Overview

About the SolaX X3-Hybrid Pro G4

The Pro is the X3 built for bigger and more awkward jobs. Three MPP trackers at 20 A each cover a 110 – 950 V window, two independent battery ports let a system grow without replacing the first stack, and the EPS output delivers twice rated power for ten seconds at UPS-level switching speed.

It is microgrid and generator ready, V2X ready and VPP compatible, with rapid shutdown compatibility and SPD-II protection on both sides. IP66 rather than IP65, which matters on an exposed wall.

560 × 503 × 210 mm and 38 kg, natural cooling on the 8 to 12 kW and smart air cooling on the 15 kW.

Battery compatibility

Which battery does this inverter take?

This inverter takes SolaX Triple Power HV, high voltage lithium.

This model has a battery voltage window of 120 – 800 V, a maximum charge or discharge current of 50 A (25 A × 2).

This rule applies to the SolaX X3-Hybrid G4 (180 – 650 V), X3-Hybrid Pro G4 and X3-Ultra (120 – 800 V).

Heated LFP modules, one master plus slaves. The window and the maximum current differ between the three X3 platforms, so read the figure in this model's own specification above.

What we stock that fits this inverter:

The three X3 platforms do not share one battery window: the X3-Hybrid G4 is 180 – 650 V, the X3-Hybrid Pro and X3-Ultra are 120 – 800 V, and the single-phase X1-Hybrid G4 is 80 – 480 V. Size the stack against the inverter in front of you, not against the brand name.
For the installer

String design, battery limits and what is in the box

The details that decide whether this unit suits the job:

  • Battery is high-voltage lithium, 120 – 800 V, 50 A total across two ports (25 A × 2). One port on a single battery is 30 A; both ports on one battery through a 2-in-1 splitter cable, sold separately, is 50 A.
  • SolaX note a minimum of three HS25 or HS36 battery units, and that if the total voltage of the three is below 127 V with no PV input, the system will not start.
  • Three MPP trackers, one string each, 20 A per tracker and 25 A Isc. 1,000 V maximum, 120 V start-up, 110 – 950 V MPPT window, 650 V rated.
  • Maximum recommended PV array is twice rated power: 16 kWp on the 8 kW, 30 kWp on the 15 kW.
  • EPS is twice rated power for 10 seconds with a switchover under 10 ms.
  • Overvoltage category is III on the mains and II on battery and PV. Surge protection is Type II on both DC and AC; AFCI is optional.
  • An energy meter is required on every installation — the SolaX M3-40 three-phase CT meter.
  • 560 × 503 × 210 mm, 38 kg, IP66, −35 °C to +60 °C with derating above +45 °C.
Applications

Where this hybrid earns its place

The X3-Hybrid Pro G4 is specified most often for these jobs.

Commercial three-phase storageUp to 30 kWp of array and two battery ports.
Microgrid and generator sitesDedicated microgrid and gen modes.
Backup with heavy start loads200 % EPS for ten seconds.
Systems that growTwo independent battery ports.
Exposed installationsIP66 rather than IP65.
EV and V2X ready sitesV2X ready, EVC and heat pump ports.
Before you order

Things worth knowing about this listing

These notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:
  • Wi-Fi is included with the G4 V2, so no separate Pocket Wi-Fi is needed.
  • An energy meter is required for every installation. Please see SOLAX-M3-40.
  • When installing in parallel, all inverters must have the same kilowatt rating.
  • When paralleling, every inverter in the system must have the same kW rating.
Technical specification

SolaX X3-HYB-8.0-P technical data

This model
Maximum PV array power16 kWp
Maximum PV input power16 kWp
Output, backup and performance
Rated AC output power8,000 W
Maximum apparent AC power8,800 VA
Rated AC output current11.6 A
Maximum AC output current13.4 A
Maximum AC input power (grid charging)16.8 kVA
Maximum AC input current24.3 A
Backup (EPS) continuous power8 kVA
CoolingNatural cooling
Common to the range
Maximum PV input voltage1,000 V
Rated PV input voltage650 V
Operation voltage range110 – 950 V
MPPT voltage range110 – 950 V
Start-up voltage120 V
Number of MPP trackers3
Strings per MPP tracker1
Maximum input current per MPPT20 A / 20 A / 20 A
Maximum input short circuit current per MPPT25 A / 25 A / 25 A
Battery typeLithium
Battery voltage range120 – 800 V
Maximum charge / discharge current50 A (25 A × 2)
Rated AC voltage3L / N / PE, 220 / 380 V, 230 / 400 V
Rated AC frequency50 Hz / 60 Hz
AC frequency range50 ±5 Hz / 60 ±5 Hz
THDi at rated power<3 %
Rated EPS output voltage and frequency230 V / 400 V, 50 / 60 Hz
Peak EPS output power2 × rated power for 10 s
EPS switch time<10 ms
Maximum efficiency98.0 %
European efficiency97.7 %
Ingress protectionIP66
Operating temperature range−35 °C to +60 °C, derating above +45 °C
Maximum operating altitude3,000 m
Relative humidity0 – 100 % RH, condensing
Overvoltage categoryMains III, battery II, PV II
Dimensions (W × H × D)560 × 503 × 210 mm
Net weight38 kg
Communication interfacesCOM1 (parallel 1, parallel 2, BMS 1, BMS 2, RS485, meter / CT); COM2 (DI/DO, EVC, XHUB, DRM, V2X, heat pump)
Power consumption at night<40 W standby, <5 W idle
TopologyNon-isolated
Active anti-islanding methodFrequency shift
Surge protectionDC Type II, AC Type II
Arc-fault circuit interrupter (AFCI)Optional
Compliance and warranty
Grid connection standardsVDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS 4777, EN 50549, CEI 0-21
Safety and EMCIEC 62109-1 / IEC 62109-2
WarrantySee the warranty document attached to this listing
Specification sourceX3-HYB-G4 PRO datasheet
Goes with this

Ordered with this inverter more often than anything else

A hybrid is the middle of a system, not the whole of it. These are the parts our customers add most often:

Frequently asked questions

Questions we get asked about this inverter

How much battery current can it take?

50 A in total: 25 A per port, or 30 A if only one port is connected to a single battery. To get the full 50 A into one battery you need the 2-in-1 splitter cable, which is sold separately.

Is there a minimum battery?

Yes. SolaX specify a minimum of three HS25 or HS36 units, and warn that if the three together sit below 127 V with no PV input, the system will not start up.

Which battery window?

120 – 800 V. That is different again from the X1-Hybrid G4 and the X3-Hybrid G4, so check the inverter before ordering a stack.

What is the EPS peak?

Twice rated power for ten seconds, switching in under 10 ms.

ClearRay Solar

Documents, advice and trade pricing

Every datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our hybrid inverter range, our batteries and our solar panels, or email sales@clearraysolar.com if you would like us to check a battery pairing or a string design before you order.

High Efficiency 98.0 %More power from the same roof space
IP66 RatedBuilt for UK weather conditions

Build your complete solar system

Everything you need in one place.

  • Inverters
  • Batteries
  • Mounting Systems
  • Cabling & Accessories
  • Protection Devices
Build a system
Shipping & Returns

Delivery times vary by region:

  • UK — 1-2 business days
  • Highlands & Islands — 1-2 business days

Returns accepted within 14 days of delivery for unused items in original packaging.