• MCS-certified products
  • Next Day Delivery
Solis 91 IN STOCKReady for immediate dispatch

S6 4kW Dual MPPT - Single Phase With DC

SOL-4.0-S6-DT-DC
£377.30 ex VAT £452.76 inc VAT

How many inverters do you need?

Secure Checkout 14-Day Returns Tracked Delivery
High Conversion EfficiencyMore of your solar reaches the home
MPPT TrackingMaximises yield in changing light
Grid CompliantMeets UK G98 / G99 requirements
Technical Specifications
Rated Power (Pmax)4 kW
Module Efficiency97.6 %
MPPT Quantity2
Min MPPT Voltage90 V
Max MPPT Voltage520 V
Max Input Voltage600 V
Max DC Power6 kW
Max AC Power (5 min)4.4 kVA
Surge AC Power (1 sec)4,400 W
Max DC Current14 A / 14 A
Max DC Inputs2
Integrated DC SwitchYes
Height543 mm
Width310 mm
Depth160 mm
Weight11.2 kg
ConnectorMC4
IP RatingIP66
Operating Temperature-25 °C to +60 °C
Warranty5 years standard, extendable to 10, 15 or 20 years
View Full Datasheet

Solis S6 4kW Dual MPPT - Single Phase With DC

Solis · S6 Dual MPPT

S6 4kW Dual MPPT - Single Phase With DC

Solis S6 Dual MPPT — Two trackers, so a split roof stops costing you generation.

A second MPP tracker is the single most useful upgrade on a British roof, and the reason is geometry rather than electronics. Very few UK houses offer one clean, unshaded, south-facing pitch. Most offer two pitches at different angles, or one pitch with a chimney, a dormer or a neighbour's tree across part of it. Wire that array as a single string and every panel is dragged down to the performance of the worst one.

Rated output
4 kWSingle phase AC output
Maximum PV input
6 kWArray size this inverter accepts
MPP trackers
2Independent maximum power point trackers
Peak efficiency
97.6 %Conversion efficiency at best
Maximum DC voltage
600 VString voltage ceiling
MPPT window
90 – 520 VWhere it tracks
Protection rating
IP66Indoor or outdoor mounting
Warranty
5 yearsStandard, extendable to 10, 15 or 20 years
Important

Please read before ordering

For export limitation and consumption monitoring =< 10m of inverter to incoming power supply then please use part (SOL-CT-100A-10M – please note: A firmware upgrade is required to the latest version for this to function). For any distances longer then this please purchase the Solis EPM (SOL-EPM1-5G)
Overview

About the Solis S6 Dual MPPT

The Solis S6 Dual MPPT range gives each pitch, or each shaded group, its own tracker and its own maximum power point. East and west arrays generate independently across the day, and a shaded group no longer taxes the clear one. In practice that is the difference between a roof being worth doing and being marginal.

The range runs from 2.5 kW to 6 kW in seven steps, all in the same 310 × 543 × 160 mm case at 11 to 12 kg, all IP66, and all with integrated AFCI arc-fault detection. The larger models accept up to 14 A per tracker, which is enough headroom for current large-format and bifacial modules rather than only for the 400 W panels of a few years ago.

For the installer

String design, certification and what is in the box

The details that decide whether this unit suits the job:

  • Two independent MPP trackers, one string each, 14 A per tracker — sized for modern high-current modules including bifacial.
  • Integrated AFCI (activation required) and integrated Export Power Manager.
  • The SKUs we stock include the integrated DC switch, so no separate rooftop or wall isolator is needed.
  • G98 and G99 certified with EN 50549-1; the certificates are attached to the listing.
  • The 4 kW to 6 kW models start at 120 V with a 90 – 520 V MPPT window; the 2.5 kW and 3 kW start at 60 V with a 50 – 450 V window, which allows notably shorter strings on small pitches.
Applications

Where this inverter earns its place

The S6 Dual MPPT is specified most often for these jobs.

East–west split roofsOne tracker per pitch, generating independently morning and evening.
Partly shaded arraysIsolate the shaded group on its own tracker so it cannot pull the clear string down.
Mixed panel countsTwo strings of unequal length are fine when each has its own tracker.
Standard 4 kW domestic installsThe 3.6 kW and 4 kW models are the volume choice for a typical UK semi.
Retrofit and extensionAdd a second orientation to an existing array without redesigning the first.
Trade rolloutsPallet quantities available for installers running repeat house types.
Battery and storage

Can I add a battery to this?

This is a grid-tied PV inverter. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.

If storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.

Technical specification

Solis S6-GR1P4K technical data

This model
Recommended maximum PV power6 kW
Maximum DC input voltage600 V
Rated DC voltage330 V
Start-up voltage120 V
MPPT voltage range90 – 520 V
Output and performance
Rated output power4 kW
Maximum apparent output power4.4 kVA
Maximum active output power4.4 kW
Rated output current18.2 A / 17.4 A
Maximum output current21.0 A
Maximum efficiency97.6 %
European weighted efficiency96.6 %
Weight11.2 kg
Common to the range
Number of MPP trackers2
Maximum input strings2, one per tracker
Maximum input current14 A / 14 A
Maximum short circuit current22 A / 22 A
Rated grid voltage1/N/PE, 220 V / 230 V
Rated grid frequency50 Hz / 60 Hz
Power factor>0.99, adjustable 0.8 leading to 0.8 lagging
THDi<3 %
TopologyTransformerless
Self consumption at night<1 W
Dimensions (W × H × D)310 × 543 × 160 mm
Operating ambient temperature−25 °C to +60 °C
Relative humidity0 – 100 %
Ingress protectionIP66
CoolingNatural convection
Maximum operating altitude4,000 m
DC connectionMC4 connector
AC connectionQuick connection plug
DisplayLCD
CommunicationRS485; Wi-Fi and GPRS optional
Integrated AFCI (DC arc fault)Yes, activation required
Compliance and warranty
Grid connection standardsG98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA
Safety and EMCIEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3
Warranty5 years standard, extendable to 10, 15 or 20 years
Specification sourceData Sheet Solis S6-GR1P(2.5-6)K
Goes with this

Ordered with this inverter more often than anything else

An inverter on its own rarely completes the job. These are the parts our customers add most often:

Frequently asked questions

Questions we get asked about this inverter

What does a second MPPT actually gain me?

On a genuinely single-orientation, unshaded roof, nothing. On a split or partly shaded roof it is typically a double-digit percentage of annual yield, because each string finds its own optimum instead of being averaged with the other.

Can I put both strings on one tracker?

You can, but then you have bought a dual-tracker inverter and used it as a single. If both pitches face the same way with the same shading it makes no difference; if they do not, split them.

Do I still need optimisers?

Usually not. Two trackers handle two orientations or one shaded group. Optimisers earn their money when shading is per-panel and moves across the array — a chimney shadow tracking across a roof through the day, for instance.

Is the DC isolator included?

Yes on the models we stock. It is integrated in the inverter.

Is it battery ready?

No. This is a grid-tied PV inverter with no battery port. If storage is on the roadmap, either plan an AC-coupled battery or choose a hybrid inverter now.

How loud is it?

It is convection cooled with no fan, so effectively silent. It can go on a hallway or bedroom wall without complaint.

ClearRay Solar

Documents, advice and trade pricing

Every datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our inverter range and our solar panels, or email our sales team at sales@clearraysolar.com if you would like us to check a string design or a compatibility question before you order.

High Efficiency 97.6 %More power from the same roof space
IP66 RatedBuilt for UK weather conditions
Have questions?

Three figures govern it, all in the Technical Specifications: the MPPT voltage range, the maximum input voltage and the maximum DC power. Tell us which panel you're pairing it with and we'll confirm the string layout.

G98 covers installations up to 3.68kW per phase and is notified to your DNO after commissioning. Anything larger needs G99 approval agreed beforehand. We can flag which one your design falls under.

A hybrid inverter takes a DC-coupled battery directly. A standard string inverter needs an AC-coupled battery alongside it. The Technical Specifications show which type this unit is.

Yes, up to the maximum DC power figure in the specifications. Modest oversizing is normal practice - it lifts output in winter and at either end of the day, at the cost of brief clipping at midday peak.

An MPPT tracks the optimum operating point for a string of panels. You want one per roof orientation or pitch, because panels facing different directions on a single tracker drag each other down.

The standard manufacturer warranty is listed under the Warranty tab. Extended cover is available on most brands - see Warranty Extensions.

Build your complete solar system

Everything you need in one place.

  • Inverters
  • Batteries
  • Mounting Systems
  • Cabling & Accessories
  • Protection Devices
Build a system