Technical Specifications
Battery TypeLithium Ion
Nominal Energy8060 Wh
Depth of Discharge96.70 %
Battery Voltage600 V
Continuous Discharge Rate4000 W
Height248 mm
Width768 mm
Depth363 mm
Weight60 kg
View Full Datasheet

Sigenergy SigenStack Battery Controller M2-0.5C BOOST

Sigenergy · SigenStack Battery Controller

Sigenergy SigenStack Battery Controller M2-0.5C BOOST

Sigenergy SigenStack Battery Controller — M2-0.5C or M2-0.5C BOOST — and on most systems only the BOOST will start.

The battery controller is the interface between a SigenStack tower and the hybrid inverter in front of it: 180 A in and 180 A out, on a 550 to 1,100 V window, with CAN to the inverter.

Part
Battery controller, BOOSTWhat this line is
Boost
YesCan it reach inverter start-up voltage
Maximum current
180 ATo and from the inverter
Operating voltage range
550 – 1,100 VDC window
Weight
60 kgPlan the lift
Overview

About the Sigenergy SigenStack Battery Controller

The suffix is the part that catches people out. BST stands for boost, and a controller carrying it can raise the battery voltage to the inverter's start-up voltage. One without it cannot.

That turns into a hard rule. If the system has PV, the BST controller is always the one to fit. If it has no PV and fewer than nineteen battery modules, BST is still essential. Only a large, PV-free system can use the plain M2-0.5C.

The 0.5C in both names is the nominal charge and discharge rate: 157 A nominal on the 0.5C controllers against 314 A on the 1C.

Compatibility

What does this fit?

This is the controller that stands between a SigenStack tower and the inverter.

One controller per system, sitting on the MAIN base. The choice between them is not a trim level: BST can boost the battery up to the inverter's start-up voltage, and the plain M2-0.5C cannot. On any system with PV, BST is essential; without PV it is essential below nineteen battery modules.

Fits
SystemSigenergy SigenStack
Systems with PVAlways required
Systems without PVRequired below nineteen battery modules
QuantityOne per system

The products it is ordered with:

For the installer

What the job needs

The details that decide whether this suits the system:

  • One controller per system, mounted on the MAIN base.
  • BST is essential on any system with PV. Without PV, BST is essential below nineteen battery modules.
  • Both move up to 180 A to and from the inverter on a 550 – 1,100 V window, over CAN.
  • Nominal battery charge and discharge current is 157 A on the 0.5C controllers. The 1C BOOST controller doubles that to 314 A.
  • 768 × 248 × 363 mm. The plain M2-0.5C is 50 kg and the BOOST version 60 kg.
  • Compatible with the Sigen Hybrid Inverter series.
Applications

Where this earns its place

The SigenStack Battery Controller is specified most often for these jobs.

Any system with PVBOOST, without exception.
Small PV-free systemsBOOST, below nineteen modules.
Large PV-free systemsThe plain M2-0.5C is viable.
Commercial SigenStack towersOne controller per system.
Before you order

Things worth knowing about this listing

These notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:
  • BST stands for boost. A SigenStack BC with the BST suffix can boost the battery voltage to the inverter start-up voltage. If there is no PV and fewer than nineteen batteries in the system, the BST controller is essential; for systems with PV the BST controller is always essential.
Technical specification

Sigenergy M2-0.5C BOOST technical data

This product
Weight60 kg
Boost capabilityBoosts the battery voltage to the inverter's start-up voltage
Essential onEvery system with PV, and any PV-free system with fewer than nineteen batteries
Common to the range
Maximum output current to the inverter180 A
Maximum input current from the inverter180 A
Operating voltage range550 – 1,100 V
Nominal battery charge / discharge current157 A
CommunicationCAN
Compatible inverterSigen Hybrid Inverter Series
Dimensions (W × H × D)768 × 248 × 363 mm
Quantity per systemOne, on the MAIN base
Compliance and warranty
WarrantySee the warranty document attached to this listing
Specification sourceSigenergy SigenStack datasheet and these listings
Frequently asked questions

Questions we get asked about this inverter

What does BST mean?

Boost. A SigenStack BC with the BST suffix can boost the battery voltage up to the inverter's start-up voltage; one without it cannot.

Which one do I need?

If the system has PV, the BST controller is always essential. If it has no PV and fewer than nineteen batteries, BST is still essential. Only a PV-free system with nineteen or more modules can use the plain M2-0.5C.

How much current will it carry?

180 A maximum to and from the inverter, on a 550 to 1,100 V window. Nominal battery charge and discharge is 157 A at 0.5C.

How many do I need?

One per system, on the MAIN base.

ClearRay Solar

Documents, advice and trade pricing

Every datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our storage range, our hybrid inverters and our batteries, or email sales@clearraysolar.com if you would like us to check a pairing before you order.

Build your complete solar system

Everything you need in one place.

  • Inverters
  • Batteries
  • Mounting Systems
  • Cabling & Accessories
  • Protection Devices
Build a system
Shipping & Returns

Delivery times vary by region:

  • UK — 1-2 business days
  • Highlands & Islands — 1-2 business days

Returns accepted within 14 days of delivery for unused items in original packaging.