
Sigenergy Power Sensor Three Phase External 300A CT
Sigenergy Power Sensor Three Phase External 300A CT
Sigenergy Power Sensor Three Phase External 300A CT
Sigenergy Sigen Power Sensor — The meter the whole system reasons from — pick it by phase, by CT and by where it has to fit.
A storage system that cannot measure the supply cannot do anything useful with it. Charge from surplus, discharge to cover the house, hold export under a G99 limit — all of it starts with a meter at the origin, and on a Sigenergy system that meter is the Sigen Power Sensor.
About the Sigenergy Sigen Power Sensor
It reports over RS485 Modbus RTU at 9,600 baud and integrates with Sigenergy devices with no configuration, which is the practical reason to fit the manufacturer's own meter rather than a generic Modbus one.
The choice comes down to three things. Single or three phase, to match the supply. Direct connection or external CTs — direct is neater but caps the service current, CTs suit anything larger or any board where the tails cannot be broken into. And whether the unit needs a display: the DH variants read out on the front, which is worth having on a commissioning visit.
At the top of the range the Rogowski version replaces clamps with flexible coils, which is the only practical way to meter a large or irregular busbar — and it scales to 1,000 A on a 6 m lead.
What does this fit?
This is the meter a Sigenergy system uses to see what the property is importing and exporting.
Every Sigenergy storage system needs a power sensor at the origin of the supply. It is what makes self-consumption, export limiting and anti-backflow possible, and it talks to the inverter over RS485 Modbus RTU. Pick single or three phase to match the supply, then pick the connection: direct, through split CTs, or through Rogowski coils on a busbar.
The products it is ordered with:
What the job needs
The details that decide whether this suits the system:
- All models: RS485, Modbus RTU, 9,600 baud. Voltage accuracy 0.5 %, power accuracy 1 %. IP20, DIN rail 35 mm, −25 °C to +65 °C, 0 – 90 % relative humidity.
- Single phase is 1P2W; three phase is 3P3W or 3P4W.
- Direct-connection models are limited to 100 A of service current. Above that, or where the tails cannot be broken, use a CT model.
- CT leads are 1 m. The CT decides the measuring range, so order the variant whose CT matches the service: 300 A and 600 A three-phase versions are listed separately.
- The Rogowski version uses three coils on 6 m leads, spans 30 Hz to 5 kHz, and refreshes in 50 ms, which is what makes it usable for anti-backflow on a busbar.
- The Sigen Sensor Sub1G Kit adds 868 MHz wireless between the sensor and the system, tested to 200 m in open space and much less through walls. It is a separate part.
- Standard compliance is EN 61010-1:2010 and EN 61010-2-030:2010.
Where this earns its place
The Sigen Power Sensor is specified most often for these jobs.
Sigenergy TP-CT300 technical data
Questions we get asked about this inverter
Do I need one of these?
Yes. A Sigenergy system meters the origin of the supply through a Sigen Power Sensor; without it there is no self-consumption control, no export limit and no anti-backflow.
Direct connection or CTs?
Direct is simpler and is rated to 100 A of service current. Use CTs above that, or wherever the incoming tails cannot be broken into.
What does DH mean?
Those models carry an LCD on the front for real-time readings, which is useful at commissioning and when fault-finding later.
Which CT rating do I need?
Match it to the service. We list 300 A and 600 A three-phase versions, and a Rogowski version that scales to 1,000 A for busbars.
Can it be wireless?
With the Sigen Sensor Sub1G Kit, yes — 868 MHz, up to 200 m in open space, considerably less through walls. It is ordered separately.
Documents, advice and trade pricing
Every datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our storage range, our hybrid inverters and our batteries, or email sales@clearraysolar.com if you would like us to check a pairing before you order.
Build your complete solar system
Everything you need in one place.
- Inverters
- Batteries
- Mounting Systems
- Cabling & Accessories
- Protection Devices
Delivery times vary by region:
- UK — 1-2 business days
- Highlands & Islands — 1-2 business days
Returns accepted within 14 days of delivery for unused items in original packaging.

