Technical Specifications
Rated Power (Pmax)25,000 W
Module Efficiency98.3 %
Min MPPT Voltage750 V
Max MPPT Voltage1,000 V
Max Input Voltage1,000 V
Max DC Power43,750 W
Max AC Power (5 min)25,000 W
Surge AC Power (1 sec)25,000 W
Max DC Current36.25 Adc
Max DC Inputs4.0
Integrated DC SwitchYes
IP RatingIP65
Warranty12 years standard, extendable to 20 years
View Full Datasheet

SolarEdge 25,000W Three Phase inverter A4 With DC Safety Unit, SPD II, RSD 30A Fuse

SolarEdge · Three Phase Commercial SE20K – SE33.3K

SolarEdge 25,000W Three Phase inverter A4 With DC Safety Unit, SPD II, RSD 30A Fuse

SolarEdge Three Phase Commercial SE20K – SE33.3K — 20 kW to 33.3 kW, with integrated Type II DC surge protection as standard.

This is SolarEdge's core commercial three-phase range and the one that turns up on most UK industrial roofs in the 20 kW to 33 kW band. It runs at a fixed 680 – 1,000 V operating window with a 1,000 V maximum, which gives long strings and 98.3 % peak efficiency.

Rated output
25,000 WThree phase AC output
Maximum PV input
43,750 WArray size this inverter accepts
Peak efficiency
98.3 %Conversion efficiency at best
Protection rating
IP65, outdoor and indoorIndoor or outdoor mounting
Warranty
12 yearsStandard, extendable to 20 years
Overview

About the SolarEdge Three Phase Commercial SE20K – SE33.3K

Two things distinguish it from the ranges below. Type II DC surge protection is integrated and field replaceable as standard, not an option — on an exposed commercial roof with long DC runs, that is the component that quietly earns its keep during a summer storm. And the optional DC Safety Unit provides 1,000 V / 48.25 A two-pole disconnection with optional 25 A or 30 A single-pole DC fuses inside the same enclosure.

Rapid shutdown is available as an option, triggering automatically on AC grid disconnect. Combined with SafeDC at the optimiser and integrated arc-fault protection, that gives a DC safety story most commercial insurers are comfortable with.

For the installer

String design, certification and what is in the box

The details that decide whether this unit suits the job:

  • Requires SolarEdge power optimisers on every module.
  • 1,000 Vdc maximum, 680 – 1,000 Vdc operating window.
  • Type II DC surge protection integrated and field replaceable as standard; AC Type II optional.
  • Optional DC Safety Unit: 1,000 V / 48.25 A two-pole disconnection, optional 25 A / 30 A DC fuses, UTE-C15-712-1 compliant.
  • Optional rapid shutdown (part numbers SExxK-xxRxxxxxx), automatic on AC grid disconnect.
  • Two RS485 ports plus Ethernet; Wi-Fi and cellular optional.
  • Note for German sites under VDE-AR-N-4110: the SE33.3K counts as a 30 kW inverter for site capacity, and current limits differ — check the datasheet footnotes.
Applications

Where this inverter earns its place

The Three Phase Commercial SE20K – SE33.3K is specified most often for these jobs.

Industrial and warehouse roofsThe volume size band for UK commercial rooftop solar.
Agricultural buildingsLarge barn roofs on three-phase supplies.
Multi-building commercial sitesOne inverter per building, all in one monitoring portal.
Retail parks and distributionDaytime load matched to generation.
Sites needing rapid shutdownWhere the fire officer or the insurer asks for automatic DC de-energisation.
Shaded or plant-cluttered roofsOptimisers handle the shading commercial roofs always turn out to have.
Battery and storage

Can I add a battery to this?

This is a grid-tied PV inverter. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.

If storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.

Technical specification

SolarEdge SE25K technical data

This model
Recommended maximum PV power43,750 W
Maximum input current36.25 Adc
Output and performance
Rated output power25,000 W
Maximum active output power25,000 VA
Maximum output current36.25 A
Maximum efficiency98.3 %
European weighted efficiency98 %
Common to the range
AC output voltage — line to line / line to neutral (nominal)380 / 220; 400 / 230 Vac
AC output voltage range304 – 437 / 176 – 253; 320 – 460 / 184 – 264.5 Vac
AC frequency50 / 60 ±5 %
AC output line connections3W + PE, 4W + PE
Total harmonic distortion<3 %
Power factor range±0.2 to 1
Maximum residual current injection100 mA
Transformer-less, ungroundedYes
Maximum input voltage DC+ to DC−1,000 Vdc
Operating voltage range680 – 1,000 Vdc
Reverse polarity protectionYes
Ground fault isolation detection167 kΩ sensitivity
Nighttime power consumption<4 W
Communication2 × RS485, Ethernet, Wi-Fi (optional), cellular (optional)
Smart energy managementExport limitation
Inverter commissioningSetApp over the built-in Wi-Fi access point
Arc fault protectionIntegrated, user configurable, to UL 1699B
Rapid shutdownOptional, automatic on AC grid disconnect
DC surge protectionType II, field replaceable, integrated
AC surge protectionType II, field replaceable, optional
DC Safety Unit (optional)Two-pole disconnection 1,000 V / 48.25 A; optional single-pole 25 A / 30 A DC fuses; UTE-C15-712-1
Ingress protectionIP65, outdoor and indoor
RoHSYes
Compliance and warranty
Grid connection standardsVDE-AR-N-4105, VDE-AR-N-4110, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, EN 50549-1, EN 50549-2, TOR Erzeuger Typ A, G99, G99 (NI), VFR 2019
Safety and EMCIEC 62109, AS 3100
Warranty12 years standard, extendable to 20 years
Specification sourceSolarEdge Three Phase Commercial Inverter for Europe, DS-000053-EU dated 17 June 2024
Frequently asked questions

Questions we get asked about this inverter

Is DC surge protection really needed?

On a commercial roof with hundreds of metres of DC cable, yes. Induced surges from nearby lightning are a leading cause of inverter failure on large arrays. Here it is fitted as standard and it is field replaceable, so a hit costs a part rather than an inverter.

What does the DC Safety Unit include?

Two-pole DC disconnection rated 1,000 V / 48.25 A, with optional single-pole 25 A or 30 A DC fuses, integrated into the inverter enclosure and compliant with UTE-C15-712-1.

Do I need optimisers?

Yes, on every module.

Can I export limit?

Yes, export limitation is part of the smart energy management feature set, and G99 is on the certification list.

What is the warranty?

12 years standard, extendable to 20.

ClearRay Solar

Documents, advice and trade pricing

Every datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our inverter range and our solar panels, or email our sales team at sales@clearraysolar.com if you would like us to check a string design or a compatibility question before you order.

High Efficiency 98.3 %More power from the same roof space
IP65 RatedBuilt for UK weather conditions

Build your complete solar system

Everything you need in one place.

  • Inverters
  • Batteries
  • Mounting Systems
  • Cabling & Accessories
  • Protection Devices
Build a system