Rated Power (Pmax)5,000 W
Module Efficiency97.6 %
Battery Voltage40 - 60 V
MPPT Quantity2
Min MPPT Voltage80 V
Max MPPT Voltage560 V
Max Input Voltage580 V
Max DC Power7,500 W
Max AC Power (5 min)5,000 VA
Max DC Current15 A / 15 A
Max DC Inputs2
Integrated DC SwitchBipolar DC switch
Height590 mm
Width540 mm
Depth240 mm
Weight32 kg
IP RatingIP65
Operating Temperature-25 °C to +60 °C
View Full Datasheet

myenergi libbi Hybrid Inverter 5kW

myenergi · libbi

myenergi libbi Hybrid Inverter 5kW

myenergi libbi — The hybrid that already speaks zappi and eddi — AC or DC coupled, 5 kWh at a time.

A hybrid inverter does three jobs a string inverter cannot. It converts solar DC to AC; it charges and discharges a battery on the DC side, which avoids the double conversion an AC-coupled battery pays for; and, with the right hardware alongside it, it can keep part of the house alive when the grid fails.

Rated AC output
5,000 WSingle phase on-grid output
Backup output
5,000 VAContinuous EPS power in a grid outage
Maximum PV input
7,500 WArray size this inverter accepts
MPP trackers
2Independent roof planes
Peak efficiency
97.6 %Conversion efficiency at best
Overview

About the myenergi libbi

libbi is myenergi's answer for a house that already has, or will have, their other kit. Stored energy can be prioritised to the house, to an eddi diverting to the hot water cylinder, or to a zappi charging the car, and all of it is set from the same app rather than from three.

It works AC coupled or DC coupled, which is the practical reason to choose it: a house with an existing PV system keeps its inverter and adds libbi alongside, while a new install can put the array straight into libbi's two MPP trackers and skip a second inverter entirely.

Storage is modular at 5 kWh a module, up to four modules and 20 kWh, and there is an optional blackout backup output for a dedicated socket or lighting circuit.

Battery compatibility

Which battery does this inverter take?

This inverter takes myenergi libbi battery modules.

This rule applies to the myenergi libbi hybrid inverter, 3.68 kW and 5 kW.

5 kWh per module, up to four modules for 20 kWh. Works AC or DC coupled, so it can take a new PV array directly or retrofit alongside an existing one.

What we stock that fits this inverter:

Low voltage and high voltage batteries are not interchangeable. A 48 V battery cannot be used on a high-voltage hybrid and a high-voltage stack cannot be used on a low-voltage one, whatever a general compatibility list says, and no adapter changes that. Solis put it plainly on their own list: installing a non-compatible battery will void the inverter warranty. If you are not certain, ask us and we will check it against your part number before you order.
For the installer

String design, battery limits and what is in the box

The details that decide whether this unit suits the job:

  • A libbi system is not one box. It is this inverter, at least one 5 kWh battery module, the cable expansion kit that matches the stack size, and the libbi controller. All four are sold separately.
  • Battery is 48 V nominal, 40 – 60 V charging window, LFP, 100 – 400 Ah, with the charging strategy set by the BMS.
  • Charge and discharge current: 50 A charge and 80 A discharge on the 3.68 kW; 100 A both ways on the 5 kW.
  • With a single battery module the charge and discharge power is limited to 2,825 W / 4,000 W. Two to four modules raise it to 3,000 W / 4,000 W on the 3.68 kW and 4,600 W / 5,000 W on the 5 kW.
  • Two MPP trackers, one string each, 15 A per tracker and 18 A Isc. 580 V maximum DC, 150 V start-up, 80 – 560 V MPPT window.
  • Recommended maximum PV is per string: 2,400 W per MPPT on the 3.68 kW and 3,750 W per MPPT on the 5 kW.
  • The backup output is a dedicated circuit, not the whole house: 4,000 VA on the 3.68 kW and 5,000 VA on the 5 kW, with a 6,900 VA peak for 10 seconds. Additional installation work usually applies.
  • 540 × 590 × 240 mm, 32 kg, IP65, convection cooled at under 25 dB, with a bipolar DC switch fitted.
Applications

Where this hybrid earns its place

The libbi is specified most often for these jobs.

Houses with a zappi or eddiStored energy is prioritised across the myenergi devices.
Retrofit onto an existing PV systemAC coupled, so the existing inverter stays.
New solar plus storageDC coupled through two MPP trackers, no second inverter.
Time-of-use and dynamic tariffsGrid charging optimised around the tariff.
Storage without solar at alllibbi will run as a grid-charged battery on its own.
A backed-up circuit rather than a backed-up houseOptional blackout backup to a socket or lighting circuit.
Before you order

Things worth knowing about this listing

These notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:
  • A libbi system is four parts: this inverter, at least one 5 kWh battery module, the cable expansion kit for that stack size, and the libbi controller. The inverter on its own will not store anything.
Technical specification

myenergi libbi 5 kW technical data

This model
Maximum PV array power7,500 W
Maximum PV input power7,500 W
Per-tracker input power split3,750 W per MPPT string
Output, backup and performance
Rated AC output power5,000 W
Maximum apparent AC power5,000 VA
Rated AC output current22 A
Maximum AC output current22 A
Backup (EPS) continuous power5,000 VA
Backup (EPS) maximum current20 A
Common to the range
Battery typeLFP (LiFePO4)
Nominal battery voltage48 V
Charging voltage range40 – 60 V
Battery capacity100 – 400 Ah
Charging strategySet by the battery BMS
Maximum DC voltage580 V
Nominal DC voltage400 V
MPPT voltage range80 – 560 V
Start-up voltage150 V
Number of MPP trackers2
Strings per MPP tracker1
Maximum input current per MPPT15 A / 15 A
Maximum short circuit current per MPPT18 A / 18 A
Nominal AC voltage230 Vac
AC grid frequency range50 / 60 Hz ±5 Hz
Maximum AC apparent power from grid7,360 VA
Maximum AC input current32 A
Power factor0.8 leading to 0.8 lagging
THDi<3 %
Backup (EPS) peak power6,900 VA for 10 s
Backup nominal output voltage230 V, 50 / 60 Hz
Backup THDv at linear load<3 %
Maximum efficiency97.6 %
European efficiency97.0 %
DC switchBipolar DC switch
TopologyBattery isolation
Dimensions (W × H × D)540 × 590 × 240 mm
Weight32 kg
Operating temperature range−25 °C to +60 °C
Noise emission<25 dB
CoolingNatural convection
Maximum operating altitude2,000 m
Maximum operating humidity0 – 95 %, non-condensing
Ingress protectionIP65
Controllerlibbi controller, indoor mounted, 230 Vac, LAN, Wi-Fi 802.11 b/g/n, RS485, 868/915 MHz wireless to myenergi sensors, 100 A grid current sensor
Compliance and warranty
Grid connection standardsG98 or G99 as applicable to the rating; ask us for the current certificate for your firmware
Safety and EMCSee the certification documents attached to this listing
WarrantySee the warranty document attached to this listing
Specification sourcemyenergi libbi datasheet DS-00001, Revision A, October 2023
Goes with this

Ordered with this inverter more often than anything else

A hybrid is the middle of a system, not the whole of it. These are the parts our customers add most often:

Frequently asked questions

Questions we get asked about this inverter

What do I actually need to order?

The inverter, at least one 5 kWh battery module, the cable expansion kit for the stack you are building, and the libbi controller. We stock all of them; the links on this page are the parts that go with this inverter.

Can I use it without solar?

Yes. libbi will charge from the grid on a time-of-use or dynamic tariff and discharge into the house, which is a common install where a roof will not take an array.

Does it work with my existing solar?

Yes, AC coupled — the existing inverter stays where it is. If you are starting from scratch you can DC couple the array into libbi's own MPP trackers instead.

What will the backup output run?

A dedicated socket or lighting circuit, not the whole house: 4,000 VA on the 3.68 kW and 5,000 VA on the 5 kW, with a short 6,900 VA peak. It usually needs extra wiring at install.

How much storage can I have?

Four modules, 20 kWh. Note that a single module limits charge and discharge power; two or more releases the inverter's full figure.

ClearRay Solar

Documents, advice and trade pricing

Every datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our hybrid inverter range, our batteries and our solar panels, or email sales@clearraysolar.com if you would like us to check a battery pairing or a string design before you order.

High Efficiency 97.6 %More power from the same roof space
IP65 RatedBuilt for UK weather conditions

Build your complete solar system

Everything you need in one place.

  • Inverters
  • Batteries
  • Mounting Systems
  • Cabling & Accessories
  • Protection Devices
Build a system
Shipping & Returns

Delivery times vary by region:

  • UK — 1-2 business days
  • Highlands & Islands — 1-2 business days

Returns accepted within 14 days of delivery for unused items in original packaging.