Technical Specifications
Rated Power (Pmax)3,000 W
Module Efficiency97.01 %
Battery Voltage80 - 480 V
MPPT Quantity2
Min MPPT Voltage80 V
Max MPPT Voltage550 V
Max Input Voltage600 V
Max DC Power4,500 W
Max AC Power (5 min)3,300 VA
Max DC Current16 / 16 A
Max DC Inputs2
Integrated DC SwitchYes
Height418 mm
Width434 mm
Depth185 mm
Weight22 kg
IP RatingIP65
Operating Temperature-25 °C to +60 °C
Warranty5 years standard, 10 years when the installation is registered with Fox ESS online
View Full Datasheet

Fox ESS Fox H1 3.0kW Hybrid Inverter with EPS 1PH Gen 2

Fox ESS · H1 Series (Gen 2) with EPS

Fox H1 3.0kW Hybrid Inverter with EPS 1PH Gen 2

Fox ESS H1 Series (Gen 2) with EPS — The volume single-phase hybrid: 16 A per tracker, 40 A battery, ten in parallel.

The G2 is the current H1 and the changes over the original are all in the places that constrain a design. DC current per tracker goes from 12.5 A to 16 A, which is what modern 450 W and larger modules need. The battery window widens to 80 – 480 V and battery current rises to 40 A, so the stack charges and discharges faster. And up to ten units can run in parallel, which takes the platform well past a single house.

Rated AC output
3,000 WSingle phase on-grid output
Backup output
3,000 VAContinuous EPS power in a grid outage
Maximum PV input
4,500 WArray size this inverter accepts
Battery window
80 – 480 VThe architecture it takes
MPP trackers
2Independent roof planes
Peak efficiency
97.01 %Conversion efficiency at best
Backup switch time
<20 msHow fast it takes over
Warranty
5 yearsStandard, 10 years when the installation is registered with Fox ESS online
Overview

About the Fox ESS H1 Series (Gen 2) with EPS

Backup is the reason most people buy a hybrid, and the G2 is honest about it: EPS output matches the rated AC power, with a 60-second peak roughly 20 % above that, and switchover in under 20 milliseconds. That is fast enough that a desktop computer does not reboot.

Round-trip matters more than headline efficiency on a hybrid, and Fox publish both halves: 98.5 % PV to battery and 97.0 % battery to AC at full load.

Battery compatibility

Which battery does this inverter take?

This inverter takes High voltage Fox ESS stacks.

This model has a battery voltage window of 80 – 480 V, a maximum charge or discharge current of 40 A, BMS communication over CAN.

A stack is one master module, which carries the BMS, plus matching slave modules of the same type. Module types are never mixed in one stack. These are the counts this inverter is listed for — Product Compatibility Fox ESS UK 2026, the module count range for this inverter family:

Battery modules this inverter accepts
CQ72 to 7 modules — 14.04 to 49.14 kWh
EQ50002 to 6 modules — 9.84 to 29.52 kWh
EQ48002 to 9 modules — 9.32 to 41.94 kWh
EQ29002 to 7 modules — 5.76 to 20.16 kWh
ECS48002 to 7 modules — 9.48 to 33.18 kWh
ECS4300 / EC43002 to 7 modules — 8.28 to 28.98 kWh
ECS41002 to 7 modules — 8.06 to 28.21 kWh
ECS29002 to 7 modules — 5.76 to 20.16 kWh
EP5 / EP61 to 4 modules — 5.18 to 20.72 kWh
EP11 / EP121 to 4 modules — 11.52 to 46.08 kWh

What we stock that fits this inverter:

Fox high-voltage modules are not mixed: a stack is one type, one master and the matching slaves, and the module count must sit inside the range above for this inverter. A Fox low-voltage battery (LV52) will not work on any of these inverters, and a high-voltage stack will not work on a low-voltage one.
For the installer

String design, battery limits and what is in the box

The details that decide whether this unit suits the job:

  • Battery window 80 – 480 V, LFP, 40 A maximum charge or discharge, CAN.
  • Two MPP trackers, one string each, 16 A per tracker and 20 A Isc. 600 V maximum DC, 75 V start-up.
  • Note the per-tracker input power split: on the 3.0 kW it is 2,250 W per tracker, rising to 4,500 W per tracker on the 6.0 kW. The array must be balanced across both.
  • Up to 10 units in parallel. EPS switch time under 20 ms.
  • DC switch and battery wake-up are fitted; AFCI is optional. SPD is DC Type II / AC Type III.
  • The 3.7 kW model is 3,680 VA for G98; 4,048 VA otherwise.
  • 434 × 418 × 185 mm, 22 kg, IP65, natural cooling, 35 dB.
Applications

Where this hybrid earns its place

The H1 Series (Gen 2) with EPS is specified most often for these jobs.

Standard UK solar plus storage3.7 kW and 5.0 kW cover most house roofs and most batteries.
Whole-circuit backupEPS matched to rated power with a 60-second peak above it.
Split and shaded roofsTwo trackers, 16 A each.
Time-of-use tariff optimisationCharge from grid overnight where the tariff pays.
Larger homes and light commercialUp to ten units in parallel.
Retrofit to an existing arrayReplaces a string inverter and adds storage in one change.
Before you order

Things worth knowing about this listing

These notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:
  • CT clamps and a Wi-Fi stick are included in the box.
  • A second CT clamp is required if the property has another generation source on the same supply — another PV system, wind or CHP.
  • A meter is required where the cable run between the inverter and the incoming supply position is more than 30 m.
  • Register the installation with Fox ESS at fox-ess.com to activate the 10-year warranty. Unregistered, the cover is 5 years.
Technical specification

Fox ESS H1-3.0-E-G2 technical data

This model
Maximum PV array power6,000 Wp
Maximum PV input power4,500 W
Per-tracker input power splitA 2,250 W / B 2,250 W
Output, backup and performance
Rated AC output power3,000 W
Maximum apparent AC power3,300 VA
Rated AC output current13.6 A
Maximum AC output current15.0 A
Maximum AC input power (grid charging)6,000 VA
Maximum AC input current27.3 A
Backup (EPS) continuous power3,000 VA
Backup (EPS) peak power3,600 VA for 60 s
Backup (EPS) maximum current13.6 A
Maximum efficiency97.01 %
European efficiency95.26 %
Common to the range
Maximum input voltage600 V
Start-up input voltage75 V
Rated input voltage360 V
MPPT operating voltage range80 – 550 V
Maximum input current16 / 16 A
Maximum short circuit current20 / 20 A
Number of MPP trackers2
Strings per MPP tracker1
Battery typeLithium battery (LFP)
Battery voltage range80 – 480 V
Maximum charge / discharge current40 A
Battery communicationCAN, communicates with the inverter and upgrades the BMS
Rated grid voltage220 / 230 / 240 V
Rated grid frequency50 / 60 Hz
Power factor1, adjustable 0.8 leading to 0.8 lagging
THDi at rated power<3 %
EPS rated output voltage220 / 230 / 240 V, 50 / 60 Hz
EPS THDv at linear load<2 %
Parallel operation10 units
EPS switch time<20 ms
Maximum battery charge efficiency, PV to battery at full load98.50 %
Maximum battery discharge efficiency, battery to AC at full load97.00 %
Insulation monitoringYes
Residual current monitoringYes
DC reverse polarity protectionYes
Anti-islanding protectionYes
DC switchYes
Battery wake-up functionYes
Surge protectionDC Type II / AC Type III
AFCIOptional
Dimensions (W × H × D)434 × 418 × 185 mm
Weight22 kg
InstallationWall mounted
TopologyNon-isolated
CoolingNatural
Noise emission35 dB
Maximum operating altitude2,000 m
Operating temperature range−25 °C to +60 °C
Humidity (non-condensing)0 – 100 %
Ingress protectionIP65
Standby consumption<15 W
MonitoringWi-Fi; LAN and 4G optional
CommunicationRS485, DRM, ripple control, USB, CAN
DisplayLCD, app and website
Compliance and warranty
Grid connection standardsG98, G99, EN 50549, AS/NZS 4777.2
Safety and EMCEN 62109-1, EN 62109-2
Warranty5 years standard, 10 years when the installation is registered with Fox ESS online
Specification sourceData Sheet Fox H1/AC1 G2 3-6 kW EN, version 1.8, 11 April 2025
Goes with this

Ordered with this inverter more often than anything else

A hybrid is the middle of a system, not the whole of it. These are the parts our customers add most often:

Frequently asked questions

Questions we get asked about this inverter

What can the backup output actually run?

The EPS matches the inverter's rated power — 5,000 VA on the H1-5.0 — with a 60-second peak of 6,000 VA for motor starting. That covers a fridge, freezer, lighting, boiler, router and sockets comfortably. An electric shower or a heat pump on full output does not fit.

How fast does it switch over?

Under 20 milliseconds. Most equipment does not notice.

Do I need optimisers?

No. This is a conventional two-tracker hybrid; put each roof plane on its own tracker.

Which battery does it take?

Fox ESS high voltage stacks inside the 80 – 480 V window. The module count depends on the battery family — Fox publish a matrix, and we list the CQ7 ranges on the battery pages.

Can I run more than one?

Yes, up to ten in parallel.

What warranty?

5 years as standard, 10 years if you register the installation with Fox ESS online. Registration is not automatic — it has to be done.

ClearRay Solar

Documents, advice and trade pricing

Every datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our hybrid inverter range, our batteries and our solar panels, or email sales@clearraysolar.com if you would like us to check a battery pairing or a string design before you order.

High Efficiency 97.01 %More power from the same roof space
IP65 RatedBuilt for UK weather conditions

Build your complete solar system

Everything you need in one place.

  • Inverters
  • Batteries
  • Mounting Systems
  • Cabling & Accessories
  • Protection Devices
Build a system