Enphase IQ7 Plus 60 and 72 cell MC4 integrated Microinverter 230 & 400VAC
The Enphase IQ7PLUS-72-M-INT is a 295 VA microinverter, one per module, with integrated Stäubli MC4 connectors and an MPP window of 27 to 45 V.
| 1 x EN-IQ7PLUS-72-M-INT | Enphase IQ7 Plus 60 and 72 cell MC4 integrated Microinverter 230 & 400VAC. | |
A microinverter converts one module's DC to grid AC at the module itself, rather than running a whole string down to a single inverter. Nothing on the roof ever carries high-voltage DC, one shaded or underperforming module cannot drag the rest of the string down with it, and every module is monitored individually.
The IQ7 series is Enphase's previous generation and remains the cost-effective choice for a straightforward array. It uses the same IQ Cabling and the same IQ Gateway as the IQ8, and IQ7 and IQ8 units can be mixed on one system.
Output (AC)
| Maximum apparent power | 295 VA |
| Rated power | 290 W |
| Nominal grid voltage | 230 V |
| Grid voltage range | 184 to 276 V |
| Nominal frequency | 50 Hz |
| Frequency range | 45 to 55 Hz |
| Maximum output current | 1.28 A |
| Total harmonic distortion | < 5% |
| Power factor range | 0.8 leading to 0.8 lagging |
| Maximum units per single phase 20 A circuit | 12 (L+N) |
| Maximum units per three phase 20 A circuit | 36 (3L+N) |
Input (DC)
| Typical module compatibility | 60-cell / 120 half-cell, 66-cell / 132 half-cell, 72-cell / 144 half-cell |
| Minimum / maximum input voltage | 16 / 60 V |
| Start-up input voltage | 22 V |
| Rated input voltage | 36 V |
| Minimum / maximum MPP voltage | 27 / 45 V |
| Minimum / maximum operating voltage | 16 / 60 V |
| Maximum input current | 12 A |
| Maximum short-circuit DC input current | 15 A |
| Maximum input power | 440 W |
| MPP trackers | 1 |
| DC input pairs per MPP tracker | 1 |
There is no enforced DC to AC ratio: a module can be paired with the microinverter as long as the maximum input voltage is not exceeded and the maximum input current is respected at the lowest and highest temperatures the site will see. Pairing a module above the input power limit simply clips.
Efficiency, mechanical and compliance
| Inverter maximum efficiency | 97.24 % |
| European weighted efficiency | 96.50 % |
| Inverter topology | Isolated (HF transformer) |
| Night-time power loss | 50 mW |
| Ambient air temperature range | −40 °C to +65 °C |
| Relative humidity range | 4% to 100%, condensing |
| Protective class | Class II |
| Overvoltage class | III (AC port) |
| DC connector | Stäubli MC4 |
| AC connector | Enphase IQ Cabling |
What else the system needs
Microinverters do not work in isolation. Every Enphase array needs an IQ Gateway to poll the units, report to Enphase Enlighten and unlock the full warranty term, and it needs IQ Cabling — the microinverters connect to a purpose-made AC trunk cable, not to ordinary T&E.
Datasheets, installation manuals and declarations of conformity are in the Documents tab below. See the rest of our microinverter range, or contact our sales team at sales@clearraysolar.com for system design and trade pricing.
Build your complete solar system
Everything you need in one place.
- Inverters
- Batteries
- Mounting Systems
- Cabling & Accessories
- Protection Devices
Delivery times vary by region:
- UK — 1-2 business days
- Highlands & Islands — 1-2 business days
Returns accepted within 14 days of delivery for unused items in original packaging.