• MCS-certified products
  • Next Day Delivery
Enphase 127 IN STOCKReady for immediate dispatch

Enphase IQ7 Plus 60 and 72 cell MC4 integrated Microinverter 230 & 400VAC.

EN-IQ7PLUS-72-M-INT
£65.08 ex VAT £78.10 inc VAT

How many inverters do you need?

Secure Checkout 14-Day Returns Tracked Delivery
High Conversion EfficiencyMore of your solar reaches the home
MPPT TrackingMaximises yield in changing light
Grid CompliantMeets UK G98 / G99 requirements
Technical Specifications
Rated Power (Pmax)295 VA
Rated Power290 W
Module Efficiency96.5 %
MPPT Quantity1
Min MPPT Voltage27 V
Max MPPT Voltage45 V
Max Input Voltage60 V
Max DC Power440 W
Max AC Power (5 min)295 VA
Surge AC Power (1 sec)295 VA
Max DC Current12 A
Max DC Inputs1
Integrated DC SwitchNo
ConnectorStäubli MC4
View Full Datasheet

Enphase IQ7 Plus 60 and 72 cell MC4 integrated Microinverter 230 & 400VAC.

The Enphase IQ7PLUS-72-M-INT is a 295 VA microinverter, one per module, with integrated Stäubli MC4 connectors and an MPP window of 27 to 45 V.

Please note you may receive a mix of INT and FR versions, functionality will not be affected as the Envoy will push the appropriate grid profile out to the microinverters regardless.

A microinverter converts one module's DC to grid AC at the module itself, rather than running a whole string down to a single inverter. Nothing on the roof ever carries high-voltage DC, one shaded or underperforming module cannot drag the rest of the string down with it, and every module is monitored individually.

The IQ7 series is Enphase's previous generation and remains the cost-effective choice for a straightforward array. It uses the same IQ Cabling and the same IQ Gateway as the IQ8, and IQ7 and IQ8 units can be mixed on one system.

Output (AC)

Maximum apparent power 295 VA
Rated power 290 W
Nominal grid voltage 230 V
Grid voltage range 184 to 276 V
Nominal frequency 50 Hz
Frequency range 45 to 55 Hz
Maximum output current 1.28 A
Total harmonic distortion < 5%
Power factor range 0.8 leading to 0.8 lagging
Maximum units per single phase 20 A circuit 12 (L+N)
Maximum units per three phase 20 A circuit 36 (3L+N)

Input (DC)

Typical module compatibility 60-cell / 120 half-cell, 66-cell / 132 half-cell, 72-cell / 144 half-cell
Minimum / maximum input voltage 16 / 60 V
Start-up input voltage 22 V
Rated input voltage 36 V
Minimum / maximum MPP voltage 27 / 45 V
Minimum / maximum operating voltage 16 / 60 V
Maximum input current 12 A
Maximum short-circuit DC input current 15 A
Maximum input power 440 W
MPP trackers 1
DC input pairs per MPP tracker 1

There is no enforced DC to AC ratio: a module can be paired with the microinverter as long as the maximum input voltage is not exceeded and the maximum input current is respected at the lowest and highest temperatures the site will see. Pairing a module above the input power limit simply clips.

Efficiency, mechanical and compliance

Inverter maximum efficiency 97.24 %
European weighted efficiency 96.50 %
Inverter topology Isolated (HF transformer)
Night-time power loss 50 mW
Ambient air temperature range −40 °C to +65 °C
Relative humidity range 4% to 100%, condensing
Protective class Class II
Overvoltage class III (AC port)
DC connector Stäubli MC4
AC connector Enphase IQ Cabling

What else the system needs

Microinverters do not work in isolation. Every Enphase array needs an IQ Gateway to poll the units, report to Enphase Enlighten and unlock the full warranty term, and it needs IQ Cabling — the microinverters connect to a purpose-made AC trunk cable, not to ordinary T&E.

Datasheets, installation manuals and declarations of conformity are in the Documents tab below. See the rest of our microinverter range, or contact our sales team at sales@clearraysolar.com for system design and trade pricing.

High Efficiency 96.5 %More power from the same roof space

Build your complete solar system

Everything you need in one place.

  • Inverters
  • Batteries
  • Mounting Systems
  • Cabling & Accessories
  • Protection Devices
Build a system