• MCS-certified products
  • Next Day Delivery
Anker SOLIX 1 IN STOCKReady for immediate dispatch

Anker Solix X1-H12K-T 3PH Power Module

ANK-X1-H12K-T
£1,402.96 ex VAT £1,683.55 inc VAT

How many inverters do you need?

Secure Checkout 14-Day Returns Tracked Delivery
High Conversion EfficiencyMore of your solar reaches the home
MPPT TrackingMaximises yield in changing light
Grid CompliantMeets UK G98 / G99 requirements
Technical Specifications
Rated Power (Pmax)12 kW
Module Efficiency98.0 %
Battery Voltage350 - 450 Vdc
MPPT Quantity2
Min MPPT Voltage140 V
Max MPPT Voltage950 V
Max Input Voltage1,000 Vdc
Max DC Power24 kW
Max AC Power (5 min)13.2 kVA
Max DC Current16 / 16 Adc
Max DC Inputs2
Integrated DC SwitchYes
Height450 mm
Width670 mm
Depth150 mm
Weight30 kg
IP RatingIP66
Operating Temperature-25 °C to +60 °C, derating above +45 °C
Warranty10 years limited
View Full Datasheet

Anker Solix X1-H12K-T 3PH Power Module

Anker SOLIX · X1 Power Module, three phase

Anker Solix X1-H12K-T 3PH Power Module

Anker SOLIX X1 Power Module, three phase — Three-phase storage in the same 150 mm column, with the CTs and the meter already in the box.

A hybrid inverter does three jobs a string inverter cannot. It converts solar DC to AC; it charges and discharges a battery on the DC side, which avoids the double conversion an AC-coupled battery pays for; and when the grid fails it islands the house and keeps a backup circuit alive from the battery.

Rated AC output
12 kWThree phase on-grid output
Backup output
12.6 kVAContinuous EPS power in a grid outage
Maximum PV input
24 kWArray size this inverter accepts
Battery window
350 – 450 VdcThe architecture it takes
MPP trackers
2Independent roof planes
Peak efficiency
98.0 %Conversion efficiency at best
Backup switch time
<10 ms (typical)How fast it takes over
Warranty
10 yearsLimited
Overview

About the Anker SOLIX X1 Power Module, three phase

The X1 is a stack rather than a wall box. The power module sits on top of one to six 5 kWh X1-B5-H battery modules on a shared base plate, 150 mm deep, behind covers that make the whole column look like one appliance. It is IP66 and C5 rated for corrosion, and the battery modules are heated, so the system keeps working down to −20 °C rather than refusing to charge on a frosty morning.

The three-phase modules go to 12 kW and take up to 24 kW of PV, with a 140 – 950 V MPPT window that suits long strings. Six units can run in parallel, and the off-grid side delivers up to 20 kVA for ten seconds, which is what starts a three-phase motor.

Battery compatibility

Which battery does this inverter take?

This inverter takes Anker SOLIX X1-B5-H, LFP.

This model has a battery voltage window of 350 – 450 Vdc.

This rule applies to the Anker SOLIX X1 power modules, single and three phase.

5 kWh per module, 5 to 30 kWh per system (1 to 6 modules). Single phase charge window 390 – 550 Vdc and discharge 370 – 500 Vdc; three phase 350 – 450 Vdc. 3 kW and 7.6 A maximum per module.

What we stock that fits this inverter:

Low voltage and high voltage batteries are not interchangeable. A 48 V battery cannot be used on a high-voltage hybrid and a high-voltage stack cannot be used on a low-voltage one, whatever a general compatibility list says, and no adapter changes that. Solis put it plainly on their own list: installing a non-compatible battery will void the inverter warranty. If you are not certain, ask us and we will check it against your part number before you order.
For the installer

String design, battery limits and what is in the box

The details that decide whether this unit suits the job:

  • Battery is the X1-B5-H, 350 – 450 Vdc on this platform, one to six modules, 5 to 30 kWh, 3 kW and 7.6 A per module.
  • Two MPP trackers, one string each, 16 A per tracker and 20 A Isc. 1,000 V maximum, 160 V start-up, 140 – 950 V MPPT window.
  • PV input goes to 200 % of rated: 16 kW on the 8 kW, 24 kW on the 12 kW.
  • Off-grid apparent power is slightly below the on-grid figure — 8.4 kVA on the 8 kW, 10.5 kVA on the 10 kW and 12.6 kVA on the 12 kW — with a 16 to 20 kVA peak for 10 seconds and a switch under 10 ms.
  • Up to six power modules in parallel. Maximum AC input is 20 kVA.
  • A DTSU 100 A current sensor and three CT clamps are in the box.
  • A stack of four or more battery modules must be floor mounted.
  • Anker do not support the X1 with a diesel generator anywhere in Europe.
  • 30 kg, 670 × 450 × 150 mm, IP66, under 30 dB, −25 °C to +60 °C with derating above +45 °C.
Applications

Where this hybrid earns its place

The X1 Power Module, three phase is specified most often for these jobs.

Three-phase homes and small units8 kW to 12 kW with up to 30 kWh behind it.
Cold sitesHeated battery modules to −20 °C.
Coastal and industrial sitesC5 anti-corrosion.
Long strings140 – 950 V MPPT window.
Motor starting on backupUp to 20 kVA for 10 seconds.
Larger installationsSix power modules in parallel.
Before you order

Things worth knowing about this listing

These notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:
  • In the box: a power sensor, three CT clamps, the base plate, side covers, both accessory kits and a Wi-Fi dongle. The DTSU 100 A current sensor is included.
  • This product cannot be installed in Belgium: its 11 kVA output exceeds the Belgian grid limit of 10 kVA. For Belgian installations choose a compliant SKU instead — ANK-X1-H5K-T or ANK-X1-H8K-T.
  • A stack of four or more battery modules must be floor mounted rather than wall mounted.
  • Anker do not support the X1 with a diesel generator anywhere in Europe.
Technical specification

Anker SOLIX X1-H12K-T technical data

This model
Maximum PV input power24 kW
Output, backup and performance
Rated AC output power12 kW
Maximum apparent AC power13.2 kVA
Backup (EPS) continuous power12.6 kVA
Backup (EPS) peak power20 kVA for 10 s
Maximum efficiency98.0 %
European efficiency97.5 %
Common to the range
Battery typeLFP
Battery voltage range350 – 450 Vdc
Battery capacity5 – 30 kWh
Maximum input voltage1,000 Vdc
MPPT voltage range140 – 950 Vdc
Start-up voltage160 Vdc
Rated input voltage600 Vdc
Maximum input current16 / 16 Adc
Maximum short circuit current20 / 20 Adc
Number of MPP trackers2
Strings per MPP tracker1
Maximum units in parallel6
Rated output voltage220/380 Vac, 230/400 Vac, 3L+N+PE
Rated frequency50 / 60 Hz
Power factor0.8 inductive to 0.8 capacitive
THDi at rated power<2 %
EPS switch time<10 ms (typical)
EPS THDu at linear load<2 %
Maximum AC input apparent power20 kVA
Internet connectivityWi-Fi, Bluetooth, Ethernet; 4G optional
Weight30 kg
Dimensions (W × H × D)670 × 450 × 150 mm
Noise emission≤30 dB at 1 m
MountingGround or wall; a wall bracket is required for wall mounting
Operating temperature range−25 °C to +60 °C, derating above +45 °C
Relative humidity0 – 100 %
Maximum operating altitude4,000 m, derating from 2,000 m
Ingress protectionIP66
Compliance and warranty
Grid connection standardsVDE-AR-N 4105, DIN VDE V 0124-100, Austria OVE Directive R25 deviation based on VDE 4105, EN 50549-1/2, EIFS 2018:2, RfG, NC RfG, PTPiREE, C10/11, UNE 217002, PPDS:2022, AS/NZS 4777.2
Safety and EMCEN IEC 62109-1, EN IEC 62109-2; EMC EN IEC 61000-6-1:2019, EN IEC 61000-6-3:2021, EN 62920:2017/A1:2021
Warranty10 years limited
Specification sourceAnker SOLIX X1 Hybrid Three-Phase Energy Storage System datasheet
Goes with this

Ordered with this inverter more often than anything else

A hybrid is the middle of a system, not the whole of it. These are the parts our customers add most often:

Frequently asked questions

Questions we get asked about this inverter

What is in the box?

A power sensor, three CT clamps, a base plate, side covers, both accessory kits and a Wi-Fi dongle. The DTSU 100 A current sensor is included, so it does not need to be quoted separately.

Which battery?

The Anker X1-B5-H, one to six modules. On the three-phase platform the window is 350 – 450 Vdc. No other battery can be used.

How much can it deliver off grid?

8.4 kVA on the 8 kW, 10.5 kVA on the 10 kW and 12.6 kVA on the 12 kW, with a peak of 16 to 20 kVA for ten seconds and a switch in under 10 ms.

Can I use a generator with it?

Not in Europe. Anker state the combination is not supported here.

Is there a country restriction?

The 12 kW module cannot be installed in Belgium, where its 11 kVA output exceeds the 10 kVA grid limit. The notes on this page say which restriction applies to the model you are looking at.

ClearRay Solar

Documents, advice and trade pricing

Every datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our hybrid inverter range, our batteries and our solar panels, or email sales@clearraysolar.com if you would like us to check a battery pairing or a string design before you order.

High Efficiency 98.0 %More power from the same roof space
IP66 RatedBuilt for UK weather conditions

Build your complete solar system

Everything you need in one place.

  • Inverters
  • Batteries
  • Mounting Systems
  • Cabling & Accessories
  • Protection Devices
Build a system
Documents & Certificates
Application Note Anker Solix X1 Installer guidlines EN 2025 CE Declaration of Conformity CE Declaration of Conformity Anker Solix x1 1ph SV (Swedish) CE Declaration of Conformity Anker Solix X1 3ph
Shipping & Returns

Delivery times vary by region:

  • UK — 1-2 business days
  • Highlands & Islands — 1-2 business days

Returns accepted within 14 days of delivery for unused items in original packaging.