{"product_id":"sol-1-5-mini-s6-eu-dc","title":"S6 Mini 1.5kW 1MPPT 1PH Inverter - with DC isolator","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · S6 Mini\u003c\/div\u003e\n    \u003ch2\u003eS6 Mini 1.5kW 1MPPT 1PH Inverter - with DC isolator\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis S6 Mini\u003c\/strong\u003e — The small single-tracker inverter that makes a modest roof worth doing.\u003c\/p\u003e\n      \u003cp\u003eMost UK roofs that get turned down for solar are turned down for the same reason: one usable pitch, room for six or eight panels, and a quote built around an inverter designed for twice that array. The Solis S6 Mini exists for exactly those roofs. It is a single-MPPT, single-phase string inverter in seven power steps from 0.7 kW to 3.6 kW, so the inverter can be sized to the array rather than the array sized to the inverter.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e1.5 kW\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e2.3 kW\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e96.6 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e600 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis S6 Mini\u003c\/h2\u003e\n    \u003cp\u003eThe engineering that matters here is at the bottom of the power curve, not the top. A 60 V start-up voltage on the smaller models and an MPPT window that opens at 50 V means the inverter is awake and exporting on a dull February morning, when a higher-threshold unit is still sitting at zero. Over a UK year that low-light behaviour is worth more than a tenth of a percent on peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eIt is also genuinely small — 310 × 373 × 160 mm and 7.4 kg — which matters more than the spec sheet suggests. It goes on a garage wall, in a loft, or in a cupboard without a second pair of hands, and it is rated IP66 so it can equally live outside.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eIntegrated AFCI (activation required) and an optional integrated DC switch — the SKUs we stock are the DC-isolator versions, so there is no separate isolator to buy, mount and wire.\u003c\/li\u003e\n        \u003cli\u003eG98 and G99 certified, with EN 50549-1 and VDE-AR-N 4105 on the same sheet, so the DNO paperwork is straightforward on either route.\u003c\/li\u003e\n        \u003cli\u003eIntegrated Export Power Manager, so an export limit can be set without an external EPM box.\u003c\/li\u003e\n        \u003cli\u003eRS485 as standard with Wi-Fi and GPRS dataloggers optional, all reporting into SolisCloud.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe S6 Mini is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSmall domestic roofs\u003c\/strong\u003e\u003cspan\u003eSix to twelve panels on one pitch, where a larger inverter would spend most of the year loafing.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSingle-orientation arrays\u003c\/strong\u003e\u003cspan\u003eOne MPPT is the right answer when every panel faces the same way and nothing shades them.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSystem top-ups\u003c\/strong\u003e\u003cspan\u003eAdding a second small array on its own inverter rather than re-engineering an existing string.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGarden rooms and outbuildings\u003c\/strong\u003e\u003cspan\u003eIP66 and 7.4 kg means it mounts where the array is, not where the house is.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRental and social housing\u003c\/strong\u003e\u003cspan\u003eLow capital cost per installed kWp on the roof sizes that dominate the housing stock.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLandlord and portfolio rollouts\u003c\/strong\u003e\u003cspan\u003eBought by the pallet, the per-unit cost drops again.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThis EU variant is supplied without the export limitation function. A meter is required for export limitation.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis S6-GR1P1.5K-M technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e2.3 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum DC input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated DC voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e60 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e14 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e22 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e1.5 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e1.65 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e1.65 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e6.8 A \/ 6.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e8.1 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e96.6 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e95.4 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e7.4 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e1\/N\/PE, 220 V \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;1 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e310 × 373 × 160 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−25 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC connection\u003c\/span\u003e\u003cstrong\u003eMC4 connector\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC connection\u003c\/span\u003e\u003cstrong\u003eQuick connection plug\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDisplay\u003c\/span\u003e\u003cstrong\u003eLCD\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; Wi-Fi and GPRS optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG98 or G99, VDE-AR-N 4105 \/ VDE V 0124, EN 50549-1, VDE 0126 \/ UTE C 15 \/ VFR:2019, RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1, CEI 0-21, C10\/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-1\/-2\/-3\/-4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet S6-GR1P(0.7-3.6)K-M - EN\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWill this work on a north-east or north-west facing roof?\u003c\/summary\u003e\u003cp\u003eYes, and the low start-up voltage is why. It will not turn a poor roof into a good one, but it will harvest the shoulders of the day that a higher-threshold inverter misses.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eOne MPPT — does that limit me?\u003c\/summary\u003e\u003cp\u003eIt limits you to one orientation and one string. If your array is split across two pitches, or is partly shaded, choose the dual-MPPT S6 range instead and put each pitch on its own tracker.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDoes it come with a DC isolator?\u003c\/summary\u003e\u003cp\u003eThe models we stock do, integrated in the unit. That removes a separate enclosure from the install and a component from the bill.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it G99 approved?\u003c\/summary\u003e\u003cp\u003eYes. G98 and G99 certificates are attached to this listing in the Documents tab, along with the EN 50549-1 declaration.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery later?\u003c\/summary\u003e\u003cp\u003eNot to this inverter — it is grid-tied only, with no battery port. You would either add an AC-coupled battery system alongside it, or replace it with a hybrid. We are happy to talk that through before you buy.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty comes with it?\u003c\/summary\u003e\u003cp\u003eFive years as standard, extendable to 10, 15 or 20 years. Registration terms are in the Solis warranty document attached to this listing.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.9 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-pdp .warning, .cr-pdp .warning p, .cr-pdp .warning li, .cr-pdp .warning dd,\n.cr-pdp .AlertText, .cr-pdp .AlertText p, .cr-pdp .AlertText li,\n.cr-pdp .prod_composite, .cr-pdp .prod_composite p, .cr-pdp .prod_composite li,\n.cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem,\n.cr-warn, .cr-warn p, .cr-warn li { opacity: 1; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.7; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":58470383223116,"sku":"SOL-1.5-MINI-S6-EU-DC","price":113.71,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-1.5-MINI-S6-EU-DC.jpg?v=1787151438","url":"https:\/\/clearraysolar.com\/products\/sol-1-5-mini-s6-eu-dc","provider":"ClearRay Solar","version":"1.0","type":"link"}