{"product_id":"sig-sensor-tp-ct100","title":"Sigenergy Power Sensor Three Phase External 100A CT","description":"\u003c!-- clearray-added-v1 --\u003e\n\u003cdiv class=\"crx\"\u003e\n\n\u003cp class=\"crx-lede\"\u003eThe Sigenergy Power Sensor TP-CT100 is the \u003cb\u003ethree phase grid meter for a Sigenergy system\u003c\/b\u003e. It sits at the grid connection point and measures each phase through \u003cb\u003eexternal current transformers rated to 100 A\u003c\/b\u003e. The Sigenergy inverter then knows exactly what the property imports and exports.\u003c\/p\u003e\n\u003cp class=\"crx-lede\"\u003eThat measurement drives the system: battery charge and discharge decisions, \u003cb\u003eexport and import limitation\u003c\/b\u003e, and the energy figures in the Sigenergy app.\u003c\/p\u003e\n\n\u003cdiv class=\"crx-facts\"\u003e\n  \u003cdiv class=\"crx-fact\"\u003e\n\u003cb\u003e100 A\u003c\/b\u003e\u003cspan\u003eMax sampling current\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"crx-fact\"\u003e\n\u003cb\u003e3-phase\u003c\/b\u003e\u003cspan\u003eSupply\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"crx-fact\"\u003e\n\u003cb\u003e1%\u003c\/b\u003e\u003cspan\u003ePower accuracy\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003cdiv class=\"crx-fact\"\u003e\n\u003cb\u003e100 ms\u003c\/b\u003e\u003cspan\u003eData refresh\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch3 class=\"crx-h\"\u003eHow it connects\u003c\/h3\u003e\n\u003cp\u003eThe sensor takes the three line conductors and neutral (L1, L2, L3, N) for voltage, and the CT leads on its CT port for current. It has an RS485 interface and an RJ45 port for the link to the inverter. Sigenergy's installation guide covers pairing by WLAN, RS485 cable or Sub-1 GHz radio, depending on the sensor variant and the inverter. Sigenergy say it integrates with their devices with no setup needed.\u003c\/p\u003e\n\n\u003ch3 class=\"crx-h\"\u003eChoosing the CT size\u003c\/h3\u003e\n\u003cp\u003eThe \"100\" in TP-CT100 is the maximum current the CTs sample. Where the current at the grid connection can exceed 100 A, choose the 300 A, 600 A or Rogowski-coil version below.\u003c\/p\u003e\n\n\u003ch3 class=\"crx-h\"\u003eOrder alongside\u003c\/h3\u003e\n\u003cul class=\"crx-need\"\u003e\n  \u003cli\u003e\n\u003ca href=\"\/products\/sig-sensor-sub1g-kit\"\u003eSigenergy Sensor Sub1G Kit\u003c\/a\u003e\n      \u003cp\u003eSigenergy's Sub-1 GHz kit for single and three phase sensors, for a wireless link where a cable run is impractical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 class=\"crx-h\"\u003eOther three phase sensors\u003c\/h3\u003e\n\u003cp\u003eThe same sensor family, sized by the current at the grid connection.\u003c\/p\u003e\n\u003cul class=\"crx-need\"\u003e\n  \u003cli\u003e\n\u003ca href=\"\/products\/sig-sensor-tp-ct300\"\u003eSigenergy Power Sensor Three Phase External 300A CT\u003c\/a\u003e\n      \u003cp\u003eUp to 300 A per phase, for larger commercial supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/products\/sig-sensor-tp-ct600-dh\"\u003eSigenergy Power Sensor Three Phase External 600A CT DH\u003c\/a\u003e\n      \u003cp\u003e600 A CTs for big three-phase intakes.\u003c\/p\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003ca href=\"\/products\/sig-sensor-tp-rc1000\"\u003eSigenergy Power Sensor Three Phase External 1000A with Rogowski coils\u003c\/a\u003e\n      \u003cp\u003eFlexible Rogowski coils up to 1000 A, for large busbars and cables that a rigid CT won't fit round.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 class=\"crx-h\"\u003eQuestions on the TP-CT100\u003c\/h3\u003e\n\u003cdiv class=\"crx-qa\"\u003e\n  \u003cdiv\u003e\n\u003cb\u003eIs it for single phase?\u003c\/b\u003e\n    \u003cp\u003eNo, it is three phase (TP). Sigenergy make single phase sensors separately.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv\u003e\n\u003cb\u003eWhat does it do for export limits?\u003c\/b\u003e\n    \u003cp\u003eIt gives the inverter the live grid flow it needs to hold export or import to a set limit.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003cdiv\u003e\n\u003cb\u003eWhich inverters does it work with?\u003c\/b\u003e\n    \u003cp\u003eSigenergy inverters. The installation guide in the Documents tab shows the wiring for each connection type.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"Default Title","offer_id":59977353789772,"sku":"SIG-SENSOR-TP-CT100","price":129.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SIG-SENSOR-TP-CT100.jpg?v=1794853169","url":"https:\/\/clearraysolar.com\/products\/sig-sensor-tp-ct100","provider":"ClearRay Solar","version":"1.0","type":"link"}