{"title":"Bulk products","description":null,"products":[{"product_id":"sda10mb-5","title":"Dektite Aluminium Multicable Solar Flashing (Tiled or Slate) (Pack of 5)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003eDektite Aluminium Multicable Solar Flashing (Tiled or Slate) (Pack of 5)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: SDA10MB-5\u003c\/dd\u003e \u003cdd\u003eCables - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003cp\u003e Keywords: SDA10MB5, Deks, PV Cable, Bulk Pack\u003c\/p\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x Dektite Aluminium Multicable Solar Flashing (Tiled or Slate) (\u003ca href=\"\/products\/SDA10MB\"\u003eSDA10MB\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"Deks","offers":[{"title":"Default Title","offer_id":57440555925836,"sku":"SDA10MB-5","price":129.2,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SDA10MB-5.jpg?v=1784590814"},{"product_id":"cable4-1-50-10","title":"4mm2 single-core 50m - Black (Pack of 10)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003e4mm2 single-core 50m - Black (Pack of 10)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: CABLE4-1-50-10\u003c\/dd\u003e \u003cdd\u003eCables - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003cp\u003e Keywords: 4mm, CABLE415010, Eland, PV Cable, Bulk Pack\u003c\/p\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x 4mm2 single-core DC cable 50m - Black (\u003ca href=\"\/products\/CABLE4-1-50\"\u003eCABLE4-1-50\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"Eland","offers":[{"title":"Default Title","offer_id":57440605208908,"sku":"CABLE4-1-50-10","price":393.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/CABLE4-1-50-10.jpg?v=1784590881"},{"product_id":"en-q-seal-10","title":"Enphase Q Cable Sealing Caps  (pack of 10)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eEnphase · trade pack\u003c\/div\u003e\n    \u003ch2\u003eEnphase Q Cable Sealing Caps  (pack of 10)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003eA trade pack of 10 units.\u003c\/p\u003e\n      \u003cp\u003eThis listing supplies 10 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x Enphase Q Cable Sealing Caps (1 Item) (\u003ca href=\"\/products\/EN-Q-SEAL\"\u003eEN-Q-SEAL\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout this pack\u003c\/h2\u003e\n    \u003cp\u003eThis listing supplies 10 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eDetails\u003c\/div\u003e\n    \u003ch2\u003eWhat this is\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eManufacturer\u003c\/span\u003e\u003cstrong\u003eEnphase\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePart number\u003c\/span\u003e\u003cstrong\u003eEN-Q-SEAL-10\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eQuantity in this pack\u003c\/span\u003e\u003cstrong\u003e10\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered alongside this item\u003c\/h2\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/en-q-seal\"\u003eEnphase Q Cable Sealing Caps (1 Item)\u003c\/a\u003e\u003cspan\u003eThe same item as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eAny datasheets we hold are in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e, or email \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you need help.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Enphase","offers":[{"title":"Default Title","offer_id":57440626245964,"sku":"EN-Q-SEAL-10","price":19.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/EN-Q-SEAL-10.jpg?v=1784591143"},{"product_id":"en-q-term-r-10","title":"Q-Cable round AC Branch Terminator  (pack of 10)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003eQ-Cable round AC Branch Terminator (pack of 10)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: EN-Q-TERM-R-10\u003c\/dd\u003e \u003cdd\u003eAccessories - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003cp\u003e Enphase round Q Cable Terminator cap for unused cable ends - required to terminate each circuit. \u003c\/p\u003e \u003cp\u003e 1x bag with 10pcs.\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"IsReduced\"\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x Q-Cable round AC Branch Terminator (1 Item) (\u003ca href=\"\/products\/EN-Q-TERM-R\"\u003eEN-Q-TERM-R\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"Enphase","offers":[{"title":"Default Title","offer_id":57440627622220,"sku":"EN-Q-TERM-R-10","price":103.36,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/EN-Q-TERM-R-10.jpg?v=1784591147"},{"product_id":"en-s-wb-230-uk-5","title":"Envoy-S Communication Gateway, 230VAC (WIFI ) (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eEnphase · trade pack\u003c\/div\u003e\n    \u003ch2\u003eEnvoy-S Communication Gateway, 230VAC (WIFI ) (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003eA trade pack of 5 units.\u003c\/p\u003e\n      \u003cp\u003eThis listing supplies 5 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x Envoy-Standard Communication Gateway, 230VAC (WIFI ) no plug. (\u003ca href=\"\/products\/EN-S-WB-230-UK\"\u003eEN-S-WB-230-UK\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout this pack\u003c\/h2\u003e\n    \u003cp\u003eThis listing supplies 5 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eDetails\u003c\/div\u003e\n    \u003ch2\u003eWhat this is\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eManufacturer\u003c\/span\u003e\u003cstrong\u003eEnphase\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePart number\u003c\/span\u003e\u003cstrong\u003eEN-S-WB-230-UK-5\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eQuantity in this pack\u003c\/span\u003e\u003cstrong\u003e5\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered alongside this item\u003c\/h2\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/en-s-wb-230-uk\"\u003eEnvoy-Standard Communication Gateway, 230VAC (WIFI ) no plug.\u003c\/a\u003e\u003cspan\u003eThe same item as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eAny datasheets we hold are in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e, or email \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you need help.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Enphase","offers":[{"title":"Default Title","offer_id":57440630505804,"sku":"EN-S-WB-230-UK-5","price":666.07,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/EN-S-WB-230-UK-5.jpg?v=1784620588"},{"product_id":"eg-bird-mesh-1m-30","title":"PVC Coated Solar Mesh – 1M Lengths  (Pack of 30)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003ePVC Coated Solar Mesh – 1M Lengths (Pack of 30)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: EG-BIRD-MESH-1M-30\u003c\/dd\u003e \u003cdd\u003eAccessories - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 30 x PVC Coated Solar Mesh - 1M Lengths (\u003ca href=\"\/products\/EG-BIRD-MESH-1M\"\u003eEG-BIRD-MESH-1M\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"Enviroguard","offers":[{"title":"Default Title","offer_id":57440641057100,"sku":"EG-BIRD-MESH-1M-30","price":31.11,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/EG-BIRD-MESH-1M-30.jpg?v=1784620600"},{"product_id":"sun2000-30ktl-m3-3","title":"Huawei SUN2000 30KTL-M3 30kW 3 phase inverter (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eHuawei · SUN2000 KTL-M3 Smart PV Controller\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000 30KTL-M3 30kW 3 phase inverter (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eHuawei SUN2000 KTL-M3 Smart PV Controller\u003c\/strong\u003e — Fuse-free by design, with AI-powered arc-fault protection.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e30,000 W\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.7 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e1,100 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 3 x SUN2000 30KTL-M3 30kW 3PH inverter (\u003ca href=\"\/products\/SUN2000-30KTL-M3\"\u003eSUN2000-30KTL-M3\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Huawei SUN2000 KTL-M3 Smart PV Controller\u003c\/h2\u003e\n    \u003cp\u003eHuawei call these Smart PV Controllers rather than inverters, and the naming is not just branding. The design goal is a commercial array that manages and diagnoses itself, so a 500 kW roof does not need a person walking it with a clamp meter.\u003c\/p\u003e\n    \u003cp\u003eTwo engineering decisions stand out. The DC side is fuse free: eight inputs across four MPP trackers, each rated 26 A to 30 A with 40 A short-circuit capability, so there are no string fuses to blow, to find, or to replace at height. And AI-powered active arcing protection listens for the signature of a DC arc and shuts down — the failure mode that starts rooftop fires and does not self-extinguish.\u003c\/p\u003e\n    \u003cp\u003eType II surge arresters on both DC and AC sides come as standard, along with PID recovery, string fault monitoring and insulation resistance detection. Peak efficiency is 98.7 % on the 30 to 40 kW models.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eFour MPP trackers, eight inputs, fuse-free DC design.\u003c\/li\u003e\n        \u003cli\u003e1,100 V maximum input, 200 V start-up, 200 – 1,000 V MPPT window, 600 V rated.\u003c\/li\u003e\n        \u003cli\u003e26 A per MPPT on the 30 to 40 kW models; 30 A per MPPT and 20 A per input on the 50 kW.\u003c\/li\u003e\n        \u003cli\u003eType II DC and AC surge arresters, PID recovery, arc fault protection and string fault monitoring all fitted.\u003c\/li\u003e\n        \u003cli\u003eMonitoring over WLAN, Ethernet or 4G via a Smart Dongle (ordered separately); MBUS supported with an isolation transformer.\u003c\/li\u003e\n        \u003cli\u003eRipple receiver control supported for networks that use it.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe SUN2000 KTL-M3 Smart PV Controller is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCommercial and industrial rooftops\u003c\/strong\u003e\u003cspan\u003e30 kW to 50 kW per unit, several per site.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGround mount arrays\u003c\/strong\u003e\u003cspan\u003eFuse-free DC removes a maintenance item across a large field.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites with fire-safety scrutiny\u003c\/strong\u003e\u003cspan\u003eActive arcing protection is a specific, testable feature.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eHuawei FusionSolar estates\u003c\/strong\u003e\u003cspan\u003eOne monitoring platform across inverters, optimisers and dongles.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eOptimiser-equipped commercial arrays\u003c\/strong\u003e\u003cspan\u003ePairs with the Huawei SUN2000-450W-P2 for module-level control.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-life assets\u003c\/strong\u003e\u003cspan\u003eIntegrated PID recovery protects yield over decades.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000-30KTL-M3 technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e26 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e30,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e33,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output voltage\u003c\/span\u003e\u003cstrong\u003e230 Vac \/ 400 Vac \/ 480 Vac, 3W\/N+PE\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e43.3 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e47.9 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.7 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98.4 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e1,100 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT operating voltage range\u003c\/span\u003e\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of inputs\u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current per MPPT\u003c\/span\u003e\u003cstrong\u003e40 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated AC grid frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAdjustable power factor range\u003c\/span\u003e\u003cstrong\u003e0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum total harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInput-side disconnection device\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAnti-islanding protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC overcurrent protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePV array string fault monitoring\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC insulation resistance detection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eResidual current monitoring unit\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRipple receiver control\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated PID recovery\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; WLAN\/Ethernet or 4G via optional Smart Dongle; MBUS with isolation transformer\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eSee the certification documents attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003eSee the warranty document attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SUN2000-30-40KTL-M and Data Sheet SUN2000-50kTL-M3\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-wlan-fe\"\u003eHuawei Smart Dongle - Wi-Fi and Ethernet Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for Wi-Fi and Ethernet monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-dongle-4g\"\u003eHuawei Smart Dongle - 4G Mobile Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for 4G, for sites with no fixed line.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sun2000-450w-p2\"\u003eHuawei SUN2000 450W Smart PV Optimizer\u003c\/a\u003e\u003cspan\u003eHuawei Smart PV Optimizer, for module-level tracking and shutdown.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does 'fuse free' mean and why does it matter?\u003c\/summary\u003e\u003cp\u003eThe DC inputs are rated to handle the full short-circuit current of the strings connected to them, so no string fuses are needed. That removes a consumable, a failure point and a reason to send someone onto a roof.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is active arcing protection?\u003c\/summary\u003e\u003cp\u003eHuawei's AI-based arc-fault detection. It monitors the DC waveform for the signature of an arc and shuts the inverter down. DC arcs are the fire risk on a PV array because, unlike AC, they do not self-extinguish at a zero crossing.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need a Smart Dongle?\u003c\/summary\u003e\u003cp\u003eFor remote monitoring, yes — WLAN\/Ethernet or 4G, ordered separately. The inverter has built-in WLAN for commissioning via the FusionSolar app.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I use Huawei optimisers with it?\u003c\/summary\u003e\u003cp\u003eYes, the SUN2000-450W-P2 and 600W-P work with these inverters over MBUS. Check the compatible-inverter list on the optimiser.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eBattery?\u003c\/summary\u003e\u003cp\u003eThese are PV inverters, not hybrids. Huawei's LUNA storage attaches to their hybrid ranges.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Huawei","offers":[{"title":"Default Title","offer_id":57440790806860,"sku":"SUN2000-30KTL-M3-3","price":5610.89,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SUN2000-30KTL-M3-3.jpg?v=1784621213"},{"product_id":"sun2000-30ktl-m3-5","title":"Huawei SUN2000 30KTL-M3 30kW 3 phase inverter (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eHuawei · SUN2000 KTL-M3 Smart PV Controller\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000 30KTL-M3 30kW 3 phase inverter (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eHuawei SUN2000 KTL-M3 Smart PV Controller\u003c\/strong\u003e — Fuse-free by design, with AI-powered arc-fault protection.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e30,000 W\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.7 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e1,100 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x SUN2000 30KTL-M3 30kW 3PH inverter (\u003ca href=\"\/products\/SUN2000-30KTL-M3\"\u003eSUN2000-30KTL-M3\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Huawei SUN2000 KTL-M3 Smart PV Controller\u003c\/h2\u003e\n    \u003cp\u003eHuawei call these Smart PV Controllers rather than inverters, and the naming is not just branding. The design goal is a commercial array that manages and diagnoses itself, so a 500 kW roof does not need a person walking it with a clamp meter.\u003c\/p\u003e\n    \u003cp\u003eTwo engineering decisions stand out. The DC side is fuse free: eight inputs across four MPP trackers, each rated 26 A to 30 A with 40 A short-circuit capability, so there are no string fuses to blow, to find, or to replace at height. And AI-powered active arcing protection listens for the signature of a DC arc and shuts down — the failure mode that starts rooftop fires and does not self-extinguish.\u003c\/p\u003e\n    \u003cp\u003eType II surge arresters on both DC and AC sides come as standard, along with PID recovery, string fault monitoring and insulation resistance detection. Peak efficiency is 98.7 % on the 30 to 40 kW models.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eFour MPP trackers, eight inputs, fuse-free DC design.\u003c\/li\u003e\n        \u003cli\u003e1,100 V maximum input, 200 V start-up, 200 – 1,000 V MPPT window, 600 V rated.\u003c\/li\u003e\n        \u003cli\u003e26 A per MPPT on the 30 to 40 kW models; 30 A per MPPT and 20 A per input on the 50 kW.\u003c\/li\u003e\n        \u003cli\u003eType II DC and AC surge arresters, PID recovery, arc fault protection and string fault monitoring all fitted.\u003c\/li\u003e\n        \u003cli\u003eMonitoring over WLAN, Ethernet or 4G via a Smart Dongle (ordered separately); MBUS supported with an isolation transformer.\u003c\/li\u003e\n        \u003cli\u003eRipple receiver control supported for networks that use it.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe SUN2000 KTL-M3 Smart PV Controller is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCommercial and industrial rooftops\u003c\/strong\u003e\u003cspan\u003e30 kW to 50 kW per unit, several per site.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGround mount arrays\u003c\/strong\u003e\u003cspan\u003eFuse-free DC removes a maintenance item across a large field.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites with fire-safety scrutiny\u003c\/strong\u003e\u003cspan\u003eActive arcing protection is a specific, testable feature.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eHuawei FusionSolar estates\u003c\/strong\u003e\u003cspan\u003eOne monitoring platform across inverters, optimisers and dongles.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eOptimiser-equipped commercial arrays\u003c\/strong\u003e\u003cspan\u003ePairs with the Huawei SUN2000-450W-P2 for module-level control.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-life assets\u003c\/strong\u003e\u003cspan\u003eIntegrated PID recovery protects yield over decades.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000-30KTL-M3 technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e26 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e30,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e33,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output voltage\u003c\/span\u003e\u003cstrong\u003e230 Vac \/ 400 Vac \/ 480 Vac, 3W\/N+PE\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e43.3 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e47.9 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.7 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98.4 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e1,100 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT operating voltage range\u003c\/span\u003e\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of inputs\u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current per MPPT\u003c\/span\u003e\u003cstrong\u003e40 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated AC grid frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAdjustable power factor range\u003c\/span\u003e\u003cstrong\u003e0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum total harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInput-side disconnection device\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAnti-islanding protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC overcurrent protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePV array string fault monitoring\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC insulation resistance detection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eResidual current monitoring unit\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRipple receiver control\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated PID recovery\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; WLAN\/Ethernet or 4G via optional Smart Dongle; MBUS with isolation transformer\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eSee the certification documents attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003eSee the warranty document attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SUN2000-30-40KTL-M and Data Sheet SUN2000-50kTL-M3\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-wlan-fe\"\u003eHuawei Smart Dongle - Wi-Fi and Ethernet Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for Wi-Fi and Ethernet monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-dongle-4g\"\u003eHuawei Smart Dongle - 4G Mobile Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for 4G, for sites with no fixed line.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sun2000-450w-p2\"\u003eHuawei SUN2000 450W Smart PV Optimizer\u003c\/a\u003e\u003cspan\u003eHuawei Smart PV Optimizer, for module-level tracking and shutdown.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does 'fuse free' mean and why does it matter?\u003c\/summary\u003e\u003cp\u003eThe DC inputs are rated to handle the full short-circuit current of the strings connected to them, so no string fuses are needed. That removes a consumable, a failure point and a reason to send someone onto a roof.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is active arcing protection?\u003c\/summary\u003e\u003cp\u003eHuawei's AI-based arc-fault detection. It monitors the DC waveform for the signature of an arc and shuts the inverter down. DC arcs are the fire risk on a PV array because, unlike AC, they do not self-extinguish at a zero crossing.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need a Smart Dongle?\u003c\/summary\u003e\u003cp\u003eFor remote monitoring, yes — WLAN\/Ethernet or 4G, ordered separately. The inverter has built-in WLAN for commissioning via the FusionSolar app.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I use Huawei optimisers with it?\u003c\/summary\u003e\u003cp\u003eYes, the SUN2000-450W-P2 and 600W-P work with these inverters over MBUS. Check the compatible-inverter list on the optimiser.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eBattery?\u003c\/summary\u003e\u003cp\u003eThese are PV inverters, not hybrids. Huawei's LUNA storage attaches to their hybrid ranges.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Huawei","offers":[{"title":"Default Title","offer_id":57440790872396,"sku":"SUN2000-30KTL-M3-5","price":9351.8,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SUN2000-30KTL-M3-5.jpg?v=1784621215"},{"product_id":"sun2000-36ktl-m3-3","title":"Huawei SUN2000 36KTL-M3 36kW 3 phase inverter (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eHuawei · SUN2000 KTL-M3 Smart PV Controller\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000 36KTL-M3 36kW 3 phase inverter (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eHuawei SUN2000 KTL-M3 Smart PV Controller\u003c\/strong\u003e — Fuse-free by design, with AI-powered arc-fault protection.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e36,000 W\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.7 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e1,100 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 3 x SUN2000 36KTL-M3 36kW 3PH inverter (BTO) (\u003ca href=\"\/products\/SUN2000-36KTL-M3\"\u003eSUN2000-36KTL-M3\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Huawei SUN2000 KTL-M3 Smart PV Controller\u003c\/h2\u003e\n    \u003cp\u003eHuawei call these Smart PV Controllers rather than inverters, and the naming is not just branding. The design goal is a commercial array that manages and diagnoses itself, so a 500 kW roof does not need a person walking it with a clamp meter.\u003c\/p\u003e\n    \u003cp\u003eTwo engineering decisions stand out. The DC side is fuse free: eight inputs across four MPP trackers, each rated 26 A to 30 A with 40 A short-circuit capability, so there are no string fuses to blow, to find, or to replace at height. And AI-powered active arcing protection listens for the signature of a DC arc and shuts down — the failure mode that starts rooftop fires and does not self-extinguish.\u003c\/p\u003e\n    \u003cp\u003eType II surge arresters on both DC and AC sides come as standard, along with PID recovery, string fault monitoring and insulation resistance detection. Peak efficiency is 98.7 % on the 30 to 40 kW models.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eFour MPP trackers, eight inputs, fuse-free DC design.\u003c\/li\u003e\n        \u003cli\u003e1,100 V maximum input, 200 V start-up, 200 – 1,000 V MPPT window, 600 V rated.\u003c\/li\u003e\n        \u003cli\u003e26 A per MPPT on the 30 to 40 kW models; 30 A per MPPT and 20 A per input on the 50 kW.\u003c\/li\u003e\n        \u003cli\u003eType II DC and AC surge arresters, PID recovery, arc fault protection and string fault monitoring all fitted.\u003c\/li\u003e\n        \u003cli\u003eMonitoring over WLAN, Ethernet or 4G via a Smart Dongle (ordered separately); MBUS supported with an isolation transformer.\u003c\/li\u003e\n        \u003cli\u003eRipple receiver control supported for networks that use it.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe SUN2000 KTL-M3 Smart PV Controller is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCommercial and industrial rooftops\u003c\/strong\u003e\u003cspan\u003e30 kW to 50 kW per unit, several per site.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGround mount arrays\u003c\/strong\u003e\u003cspan\u003eFuse-free DC removes a maintenance item across a large field.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites with fire-safety scrutiny\u003c\/strong\u003e\u003cspan\u003eActive arcing protection is a specific, testable feature.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eHuawei FusionSolar estates\u003c\/strong\u003e\u003cspan\u003eOne monitoring platform across inverters, optimisers and dongles.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eOptimiser-equipped commercial arrays\u003c\/strong\u003e\u003cspan\u003ePairs with the Huawei SUN2000-450W-P2 for module-level control.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-life assets\u003c\/strong\u003e\u003cspan\u003eIntegrated PID recovery protects yield over decades.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000-36KTL-M3 technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e26 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e36,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e40,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output voltage\u003c\/span\u003e\u003cstrong\u003e230 Vac \/ 400 Vac \/ 480 Vac, 3W\/N+PE\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e52.0 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e58.0 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.7 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98.4 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e1,100 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT operating voltage range\u003c\/span\u003e\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of inputs\u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current per MPPT\u003c\/span\u003e\u003cstrong\u003e40 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated AC grid frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAdjustable power factor range\u003c\/span\u003e\u003cstrong\u003e0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum total harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInput-side disconnection device\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAnti-islanding protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC overcurrent protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePV array string fault monitoring\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC insulation resistance detection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eResidual current monitoring unit\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRipple receiver control\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated PID recovery\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; WLAN\/Ethernet or 4G via optional Smart Dongle; MBUS with isolation transformer\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eSee the certification documents attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003eSee the warranty document attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SUN2000-30-40KTL-M and Data Sheet SUN2000-50kTL-M3\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-wlan-fe\"\u003eHuawei Smart Dongle - Wi-Fi and Ethernet Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for Wi-Fi and Ethernet monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-dongle-4g\"\u003eHuawei Smart Dongle - 4G Mobile Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for 4G, for sites with no fixed line.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sun2000-450w-p2\"\u003eHuawei SUN2000 450W Smart PV Optimizer\u003c\/a\u003e\u003cspan\u003eHuawei Smart PV Optimizer, for module-level tracking and shutdown.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does 'fuse free' mean and why does it matter?\u003c\/summary\u003e\u003cp\u003eThe DC inputs are rated to handle the full short-circuit current of the strings connected to them, so no string fuses are needed. That removes a consumable, a failure point and a reason to send someone onto a roof.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is active arcing protection?\u003c\/summary\u003e\u003cp\u003eHuawei's AI-based arc-fault detection. It monitors the DC waveform for the signature of an arc and shuts the inverter down. DC arcs are the fire risk on a PV array because, unlike AC, they do not self-extinguish at a zero crossing.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need a Smart Dongle?\u003c\/summary\u003e\u003cp\u003eFor remote monitoring, yes — WLAN\/Ethernet or 4G, ordered separately. The inverter has built-in WLAN for commissioning via the FusionSolar app.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I use Huawei optimisers with it?\u003c\/summary\u003e\u003cp\u003eYes, the SUN2000-450W-P2 and 600W-P work with these inverters over MBUS. Check the compatible-inverter list on the optimiser.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eBattery?\u003c\/summary\u003e\u003cp\u003eThese are PV inverters, not hybrids. Huawei's LUNA storage attaches to their hybrid ranges.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Huawei","offers":[{"title":"Default Title","offer_id":57440791101772,"sku":"SUN2000-36KTL-M3-3","price":5862.58,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SUN2000-36KTL-M3-3.jpg?v=1784621216"},{"product_id":"sun2000-36ktl-m3-5","title":"Huawei SUN2000 36KTL-M3 36kW 3 phase inverter (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eHuawei · SUN2000 KTL-M3 Smart PV Controller\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000 36KTL-M3 36kW 3 phase inverter (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eHuawei SUN2000 KTL-M3 Smart PV Controller\u003c\/strong\u003e — Fuse-free by design, with AI-powered arc-fault protection.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e36,000 W\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.7 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e1,100 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x SUN2000 36KTL-M3 36kW 3PH inverter (BTO) (\u003ca href=\"\/products\/SUN2000-36KTL-M3\"\u003eSUN2000-36KTL-M3\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Huawei SUN2000 KTL-M3 Smart PV Controller\u003c\/h2\u003e\n    \u003cp\u003eHuawei call these Smart PV Controllers rather than inverters, and the naming is not just branding. The design goal is a commercial array that manages and diagnoses itself, so a 500 kW roof does not need a person walking it with a clamp meter.\u003c\/p\u003e\n    \u003cp\u003eTwo engineering decisions stand out. The DC side is fuse free: eight inputs across four MPP trackers, each rated 26 A to 30 A with 40 A short-circuit capability, so there are no string fuses to blow, to find, or to replace at height. And AI-powered active arcing protection listens for the signature of a DC arc and shuts down — the failure mode that starts rooftop fires and does not self-extinguish.\u003c\/p\u003e\n    \u003cp\u003eType II surge arresters on both DC and AC sides come as standard, along with PID recovery, string fault monitoring and insulation resistance detection. Peak efficiency is 98.7 % on the 30 to 40 kW models.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eFour MPP trackers, eight inputs, fuse-free DC design.\u003c\/li\u003e\n        \u003cli\u003e1,100 V maximum input, 200 V start-up, 200 – 1,000 V MPPT window, 600 V rated.\u003c\/li\u003e\n        \u003cli\u003e26 A per MPPT on the 30 to 40 kW models; 30 A per MPPT and 20 A per input on the 50 kW.\u003c\/li\u003e\n        \u003cli\u003eType II DC and AC surge arresters, PID recovery, arc fault protection and string fault monitoring all fitted.\u003c\/li\u003e\n        \u003cli\u003eMonitoring over WLAN, Ethernet or 4G via a Smart Dongle (ordered separately); MBUS supported with an isolation transformer.\u003c\/li\u003e\n        \u003cli\u003eRipple receiver control supported for networks that use it.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe SUN2000 KTL-M3 Smart PV Controller is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCommercial and industrial rooftops\u003c\/strong\u003e\u003cspan\u003e30 kW to 50 kW per unit, several per site.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGround mount arrays\u003c\/strong\u003e\u003cspan\u003eFuse-free DC removes a maintenance item across a large field.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites with fire-safety scrutiny\u003c\/strong\u003e\u003cspan\u003eActive arcing protection is a specific, testable feature.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eHuawei FusionSolar estates\u003c\/strong\u003e\u003cspan\u003eOne monitoring platform across inverters, optimisers and dongles.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eOptimiser-equipped commercial arrays\u003c\/strong\u003e\u003cspan\u003ePairs with the Huawei SUN2000-450W-P2 for module-level control.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-life assets\u003c\/strong\u003e\u003cspan\u003eIntegrated PID recovery protects yield over decades.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000-36KTL-M3 technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e26 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e36,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e40,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output voltage\u003c\/span\u003e\u003cstrong\u003e230 Vac \/ 400 Vac \/ 480 Vac, 3W\/N+PE\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e52.0 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e58.0 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.7 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98.4 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e1,100 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT operating voltage range\u003c\/span\u003e\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of inputs\u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current per MPPT\u003c\/span\u003e\u003cstrong\u003e40 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated AC grid frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAdjustable power factor range\u003c\/span\u003e\u003cstrong\u003e0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum total harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInput-side disconnection device\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAnti-islanding protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC overcurrent protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePV array string fault monitoring\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC insulation resistance detection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eResidual current monitoring unit\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRipple receiver control\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated PID recovery\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; WLAN\/Ethernet or 4G via optional Smart Dongle; MBUS with isolation transformer\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eSee the certification documents attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003eSee the warranty document attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SUN2000-30-40KTL-M and Data Sheet SUN2000-50kTL-M3\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-wlan-fe\"\u003eHuawei Smart Dongle - Wi-Fi and Ethernet Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for Wi-Fi and Ethernet monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-dongle-4g\"\u003eHuawei Smart Dongle - 4G Mobile Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for 4G, for sites with no fixed line.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sun2000-450w-p2\"\u003eHuawei SUN2000 450W Smart PV Optimizer\u003c\/a\u003e\u003cspan\u003eHuawei Smart PV Optimizer, for module-level tracking and shutdown.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does 'fuse free' mean and why does it matter?\u003c\/summary\u003e\u003cp\u003eThe DC inputs are rated to handle the full short-circuit current of the strings connected to them, so no string fuses are needed. That removes a consumable, a failure point and a reason to send someone onto a roof.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is active arcing protection?\u003c\/summary\u003e\u003cp\u003eHuawei's AI-based arc-fault detection. It monitors the DC waveform for the signature of an arc and shuts the inverter down. DC arcs are the fire risk on a PV array because, unlike AC, they do not self-extinguish at a zero crossing.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need a Smart Dongle?\u003c\/summary\u003e\u003cp\u003eFor remote monitoring, yes — WLAN\/Ethernet or 4G, ordered separately. The inverter has built-in WLAN for commissioning via the FusionSolar app.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I use Huawei optimisers with it?\u003c\/summary\u003e\u003cp\u003eYes, the SUN2000-450W-P2 and 600W-P work with these inverters over MBUS. Check the compatible-inverter list on the optimiser.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eBattery?\u003c\/summary\u003e\u003cp\u003eThese are PV inverters, not hybrids. Huawei's LUNA storage attaches to their hybrid ranges.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Huawei","offers":[{"title":"Default Title","offer_id":57440791200076,"sku":"SUN2000-36KTL-M3-5","price":9770.97,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SUN2000-36KTL-M3-5.jpg?v=1784621217"},{"product_id":"sun2000-40ktl-m3-3","title":"Huawei SUN2000 40KTL-M3 40kW 3 phase inverter (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eHuawei · SUN2000 KTL-M3 Smart PV Controller\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000 40KTL-M3 40kW 3 phase inverter (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eHuawei SUN2000 KTL-M3 Smart PV Controller\u003c\/strong\u003e — Fuse-free by design, with AI-powered arc-fault protection.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e40,000 W\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.7 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e1,100 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Huawei SUN2000 KTL-M3 Smart PV Controller\u003c\/h2\u003e\n    \u003cp\u003eHuawei call these Smart PV Controllers rather than inverters, and the naming is not just branding. The design goal is a commercial array that manages and diagnoses itself, so a 500 kW roof does not need a person walking it with a clamp meter.\u003c\/p\u003e\n    \u003cp\u003eTwo engineering decisions stand out. The DC side is fuse free: eight inputs across four MPP trackers, each rated 26 A to 30 A with 40 A short-circuit capability, so there are no string fuses to blow, to find, or to replace at height. And AI-powered active arcing protection listens for the signature of a DC arc and shuts down — the failure mode that starts rooftop fires and does not self-extinguish.\u003c\/p\u003e\n    \u003cp\u003eType II surge arresters on both DC and AC sides come as standard, along with PID recovery, string fault monitoring and insulation resistance detection. Peak efficiency is 98.7 % on the 30 to 40 kW models.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eFour MPP trackers, eight inputs, fuse-free DC design.\u003c\/li\u003e\n        \u003cli\u003e1,100 V maximum input, 200 V start-up, 200 – 1,000 V MPPT window, 600 V rated.\u003c\/li\u003e\n        \u003cli\u003e26 A per MPPT on the 30 to 40 kW models; 30 A per MPPT and 20 A per input on the 50 kW.\u003c\/li\u003e\n        \u003cli\u003eType II DC and AC surge arresters, PID recovery, arc fault protection and string fault monitoring all fitted.\u003c\/li\u003e\n        \u003cli\u003eMonitoring over WLAN, Ethernet or 4G via a Smart Dongle (ordered separately); MBUS supported with an isolation transformer.\u003c\/li\u003e\n        \u003cli\u003eRipple receiver control supported for networks that use it.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe SUN2000 KTL-M3 Smart PV Controller is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCommercial and industrial rooftops\u003c\/strong\u003e\u003cspan\u003e30 kW to 50 kW per unit, several per site.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGround mount arrays\u003c\/strong\u003e\u003cspan\u003eFuse-free DC removes a maintenance item across a large field.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites with fire-safety scrutiny\u003c\/strong\u003e\u003cspan\u003eActive arcing protection is a specific, testable feature.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eHuawei FusionSolar estates\u003c\/strong\u003e\u003cspan\u003eOne monitoring platform across inverters, optimisers and dongles.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eOptimiser-equipped commercial arrays\u003c\/strong\u003e\u003cspan\u003ePairs with the Huawei SUN2000-450W-P2 for module-level control.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-life assets\u003c\/strong\u003e\u003cspan\u003eIntegrated PID recovery protects yield over decades.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eHuawei SUN2000-40KTL-M3 technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e26 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e40,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e44,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output voltage\u003c\/span\u003e\u003cstrong\u003e230 Vac \/ 400 Vac \/ 480 Vac, 3W\/N+PE\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e57.8 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e63.8 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.7 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98.4 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e1,100 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT operating voltage range\u003c\/span\u003e\u003cstrong\u003e200 – 1,000 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of inputs\u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current per MPPT\u003c\/span\u003e\u003cstrong\u003e40 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated AC grid frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAdjustable power factor range\u003c\/span\u003e\u003cstrong\u003e0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum total harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInput-side disconnection device\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAnti-islanding protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC overcurrent protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePV array string fault monitoring\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC surge arrester\u003c\/span\u003e\u003cstrong\u003eYes, Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC insulation resistance detection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eResidual current monitoring unit\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRipple receiver control\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated PID recovery\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; WLAN\/Ethernet or 4G via optional Smart Dongle; MBUS with isolation transformer\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eSee the certification documents attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003eSee the warranty document attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SUN2000-30-40KTL-M and Data Sheet SUN2000-50kTL-M3\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-wlan-fe\"\u003eHuawei Smart Dongle - Wi-Fi and Ethernet Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for Wi-Fi and Ethernet monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/hua-smart-dongle-4g\"\u003eHuawei Smart Dongle - 4G Mobile Network adapter\u003c\/a\u003e\u003cspan\u003eSmart Dongle for 4G, for sites with no fixed line.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sun2000-450w-p2\"\u003eHuawei SUN2000 450W Smart PV Optimizer\u003c\/a\u003e\u003cspan\u003eHuawei Smart PV Optimizer, for module-level tracking and shutdown.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does 'fuse free' mean and why does it matter?\u003c\/summary\u003e\u003cp\u003eThe DC inputs are rated to handle the full short-circuit current of the strings connected to them, so no string fuses are needed. That removes a consumable, a failure point and a reason to send someone onto a roof.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is active arcing protection?\u003c\/summary\u003e\u003cp\u003eHuawei's AI-based arc-fault detection. It monitors the DC waveform for the signature of an arc and shuts the inverter down. DC arcs are the fire risk on a PV array because, unlike AC, they do not self-extinguish at a zero crossing.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need a Smart Dongle?\u003c\/summary\u003e\u003cp\u003eFor remote monitoring, yes — WLAN\/Ethernet or 4G, ordered separately. The inverter has built-in WLAN for commissioning via the FusionSolar app.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I use Huawei optimisers with it?\u003c\/summary\u003e\u003cp\u003eYes, the SUN2000-450W-P2 and 600W-P work with these inverters over MBUS. Check the compatible-inverter list on the optimiser.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eBattery?\u003c\/summary\u003e\u003cp\u003eThese are PV inverters, not hybrids. Huawei's LUNA storage attaches to their hybrid ranges.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Huawei","offers":[{"title":"Default Title","offer_id":57440791298380,"sku":"SUN2000-40KTL-M3-3","price":6276.01,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SUN2000-40KTL-M3-3.jpg?v=1784621218"},{"product_id":"kg20b-t106d-10","title":"K\u0026N Single String DC Switch 21A 800V - 20A 1000V (Pack of 10)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003eK\u0026amp;N Single String DC Switch 21A 800V - 20A 1000V (Pack of 10)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: KG20B-T106D-10\u003c\/dd\u003e \u003cdd\u003eSwitches - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003cp\u003e Keywords: 96kW, KG20BT106D10, Kraus \u0026amp; Naimer, Switches, Bulk Pack,DC ISOLATER,DC Isolater, dc isolaters, isolaters\u003c\/p\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x K\u0026amp;N Single String DC Switch Disconnector 21A 800V - 20A 1000V (\u003ca href=\"\/products\/KG20B-T106D\"\u003eKG20B-T106D\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"Kraus \u0026 Naimer","offers":[{"title":"Default Title","offer_id":57440836550988,"sku":"KG20B-T106D-10","price":461.27,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/KG20B-T106D-10.jpg?v=1784621637"},{"product_id":"kg20b-t106gb-10","title":"K\u0026N Dual String DC Switch Disconnector 25A 330V - 11A 690V (per string) (Pack of 10)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003eK\u0026amp;N Dual String DC Switch Disconnector 25A 330V - 11A 690V (per string) (Pack of 10)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: KG20B-T106GB-10\u003c\/dd\u003e \u003cdd\u003eSwitches - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003cp\u003e Keywords: KG20BT106GB10, Kraus \u0026amp; Naimer, Switches, Bulk Pack, DC ISOLATER, DC Isolater, dc isolaters, isolaters\u003c\/p\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x K\u0026amp;N Dual String DC Switch Disconnector 25A 330V - 18A 600V (per string) (\u003ca href=\"\/products\/KG20B-T106GB\"\u003eKG20B-T106GB\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"Kraus \u0026 Naimer","offers":[{"title":"Default Title","offer_id":57440836714828,"sku":"KG20B-T106GB-10","price":461.27,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/KG20B-T106GB-10.jpg?v=1784621640"},{"product_id":"kg20-t104d-10","title":"K\u0026N Single String DC Switch Disconnector 25A 450V - 11A 920V (Pack of 10)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003eK\u0026amp;N Single String DC Switch Disconnector 25A 450V - 11A 920V (Pack of 10)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: KG20-T104D-10\u003c\/dd\u003e \u003cdd\u003eSwitches - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003cp\u003e Keywords: KG20T104D10, Kraus \u0026amp; Naimer, Switches, Bulk Pack, DC ISOLATER, DC Isolater, dc isolaters, isolaters\u003c\/p\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x K\u0026amp;N Single String DC Switch Disconnector 25A 450V - 18A 800V (\u003ca href=\"\/products\/KG20-T104D\"\u003eKG20-T104D\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/KG20-T104D-40\"\u003eK\u0026amp;N Single String DC Switch 25A 450V - 11A 920V (Pack of 40)\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"Kraus \u0026 Naimer","offers":[{"title":"Default Title","offer_id":57440836911436,"sku":"KG20-T104D-10","price":315.81,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/KG20-T104D-10.jpg?v=1784621642"},{"product_id":"kg20-t104gb-10","title":"K\u0026N Dual String DC Switch Disconnector 25A 220V - 11A 460V (per string) (Pack of 10)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003eK\u0026amp;N Dual String DC Switch Disconnector 25A 220V - 11A 460V (per string) (Pack of 10)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: KG20-T104GB-10\u003c\/dd\u003e \u003cdd\u003eSwitches - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003cp\u003e Keywords: KG20T104GB10, Kraus \u0026amp; Naimer, Switches, Bulk Pack\u0026lt;, DC ISOLATER, DC Isolater, dc isolaters\u003c\/p\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x K\u0026amp;N Dual String DC Switch Disconnector 25A 220V - 18A 400V (per string) (\u003ca href=\"\/products\/KG20-T104GB\"\u003eKG20-T104GB\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"Kraus \u0026 Naimer","offers":[{"title":"Default Title","offer_id":57440837173580,"sku":"KG20-T104GB-10","price":315.81,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/KG20-T104GB-10.jpg?v=1784621646"},{"product_id":"kg20-t203-gba294-25","title":"K\u0026N Single Phase AC Switch Disconnector 25A (Pack of 25)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003eK\u0026amp;N Single Phase AC Switch Disconnector 25A (Pack of 25)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: KG20-T203-GBA294-25\u003c\/dd\u003e \u003cdd\u003eSwitches - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003cp\u003e Keywords: 143kW, KG20T203GBA29425, Kraus \u0026amp; Naimer, Switches, Bulk Pack\u003c\/p\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 25 x K\u0026amp;N Single Phase AC Switch Disconnector 25A (\u003ca href=\"\/products\/KG20-T203-GBA294\"\u003eKG20-T203-GBA294\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"Kraus \u0026 Naimer","offers":[{"title":"Default Title","offer_id":57440837402956,"sku":"KG20-T203-GBA294-25","price":656.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/KG20-T203-GBA294-25.jpg?v=1784621649"},{"product_id":"myen-ct100-16-05-10","title":"myenergi Current Transformer with 5m cable (100A 16mm) (Pack of 10)","description":"\u003cp\u003e\u003cstrong\u003emyenergi Current Transformer with 5m cable (100A 16mm) (Pack of 10)\u003c\/strong\u003e — part no. MYEN-CT100-16-05-10.\u003c\/p\u003e\n\u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x myenergi Current Transformer with 5m cable (100A 16mm) (\u003ca href=\"\/products\/MYEN-CT100-16-05\"\u003eMYEN-CT100-16-05\u003c\/a\u003e)\u003c\/div\u003e\n\u003ch3\u003eAdditional suggested items\u003c\/h3\u003e\u003cp\u003eUsually ordered at the same time:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/myen-zappi-2h07tb-g\"\u003eZappi Single Phase EV Charge Point 7kW Type 2 Tethered Black\u003c\/a\u003e — the 7 kW tethered zappi these sensors feed\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/myen-harvi-65a3p\"\u003emyenergi harvi - energy harvesting wireless sensor\u003c\/a\u003e — wireless CT sensor, so no signal cable is needed back to the consumer unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDatasheets, installation manuals and declarations of conformity are in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/ev-charging\"\u003eev charging\u003c\/a\u003e range, or contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for trade pricing.\u003c\/p\u003e","brand":"myenergi","offers":[{"title":"Default Title","offer_id":57440841236812,"sku":"MYEN-CT100-16-05-10","price":163.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/MYEN-CT100-16-05-10.jpg?v=1784621735"},{"product_id":"myen-eddi-16a1p02h-10","title":"myenergi eddi 2.1 - Energy Diverter (wifi enabled)  (Pack of 10)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003emyenergi eddi 2.1 - Energy Diverter (wifi enabled) (Pack of 10)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: MYEN-EDDI-16A1P02H-10\u003c\/dd\u003e \u003cdd\u003eAccessories - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x myenergi eddi 2.1 - Energy Diverter (wifi enabled) (\u003ca href=\"\/products\/MYEN-EDDI-16A1P02H\"\u003eMYEN-EDDI-16A1P02H\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/MYEN-EDDI-16A1P02H-45\"\u003emyenergi eddi 2.1 - Energy Diverter (wifi enabled) (Pack of 45)\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"myenergi","offers":[{"title":"Default Title","offer_id":57440841433420,"sku":"MYEN-EDDI-16A1P02H-10","price":3566.74,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/MYEN-EDDI-16A1P02H-10.jpg?v=1784621741"},{"product_id":"myen-eddi-16a1p02h-45","title":"myenergi eddi 2.1 - Energy Diverter (wifi enabled)  (Pack of 45)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003emyenergi eddi 2.1 - Energy Diverter (wifi enabled) (Pack of 45)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: MYEN-EDDI-16A1P02H-45\u003c\/dd\u003e \u003cdd\u003eAccessories - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003c\/div\u003e \u003cdiv class=\"IsReduced\"\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 45 x myenergi eddi 2.1 - Energy Diverter (wifi enabled) (\u003ca href=\"\/products\/MYEN-EDDI-16A1P02H\"\u003eMYEN-EDDI-16A1P02H\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/MYEN-EDDI-16A1P02H-10\"\u003emyenergi eddi 2.1 - Energy Diverter (wifi enabled) (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"myenergi","offers":[{"title":"Default Title","offer_id":57440841531724,"sku":"MYEN-EDDI-16A1P02H-45","price":16048.89,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/MYEN-EDDI-16A1P02H-45.jpg?v=1784621744"},{"product_id":"myen-harvi-65a3p-5","title":"myenergi harvi - energy harvesting wireless sensor (Pack of 5)","description":"\u003cp\u003e\u003cstrong\u003emyenergi harvi - energy harvesting wireless sensor (Pack of 5)\u003c\/strong\u003e — part no. MYEN-HARVI-65A3P-5.\u003c\/p\u003e\n\u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x myenergi harvi - energy harvesting wireless sensor (\u003ca href=\"\/products\/MYEN-HARVI-65A3P\"\u003eMYEN-HARVI-65A3P\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/MYEN-HARVI-65A3P-10\"\u003emyenergi harvi - energy harvesting wireless sensor (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e\n\u003ch3\u003eAdditional suggested items\u003c\/h3\u003e\u003cp\u003eUsually ordered at the same time:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/myen-harvi-65a3p\"\u003emyenergi harvi - energy harvesting wireless sensor\u003c\/a\u003e — wireless CT sensor, so no signal cable is needed back to the consumer unit\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dc-ev-ultra5c6-0cat5swa-10\"\u003e6mm2 Five Core Cat5e EV Ultra Cable with SWA Sleeve - 10m\u003c\/a\u003e — power and Cat5e data in one armoured cable, for the run out to the charger\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/myen-hub\"\u003emyenergi hub - monitoring remote control unit\u003c\/a\u003e — adds remote monitoring and control through the myenergi app\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDatasheets, installation manuals and declarations of conformity are in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/ev-charging\"\u003eev charging\u003c\/a\u003e range, or contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for trade pricing.\u003c\/p\u003e","brand":"myenergi","offers":[{"title":"Default Title","offer_id":57440842252620,"sku":"MYEN-HARVI-65A3P-5","price":290.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/MYEN-HARVI-65A3P-5.jpg?v=1784621766"},{"product_id":"enet-hbcl-01-5","title":"SolarEdge Home Network - SetApp Inverters (Pack of 5)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003eSolarEdge Home Network - SetApp Inverters (Pack of 5)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: ENET-HBCL-01-5\u003c\/dd\u003e \u003cdd\u003eAccessories - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x SolarEdge Home Network - SetApp Inverters (\u003ca href=\"\/products\/ENET-HBCL-01\"\u003eENET-HBCL-01\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440898253132,"sku":"ENET-HBCL-01-5","price":125.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/ENET-HBCL-01-5.jpg?v=1778196012"},{"product_id":"enet-hbnp-01-5","title":"SolarEdge Home Network - ENET Ready Inverters (Pack of 5)","description":"\u003cdiv class=\"pp_description\"\u003e \u003cdl\u003e \u003cdt\u003eSolarEdge Home Network - ENET Ready Inverters (Pack of 5)\u003c\/dt\u003e \u003cdd class=\"first\"\u003ePart No: ENET-HBNP-01-5\u003c\/dd\u003e \u003cdd\u003eAccessories - Bulk Packs\u003c\/dd\u003e \u003cul class=\"list\"\u003e \u003c\/ul\u003e \u003cdiv class=\"item_description\"\u003e \u003cdiv class=\"TextSummary\"\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x Home Network - ENET Ready Inverters (\u003ca href=\"\/products\/ENET-HBNP-01\"\u003eENET-HBNP-01\u003c\/a\u003e)\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/dl\u003e \u003c\/div\u003e","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440898384204,"sku":"ENET-HBNP-01-5","price":97.61,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/ENET-HBNP-01-5.jpg?v=1778196014"},{"product_id":"p1100-2-4-mc4-200","title":"SolarEdge P1100 Optimizer 1100W MC4 2 x high power or bi-facial modules (Pack of 200)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · trade pack\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge P1100 Optimizer 1100W MC4 2 x high power or bi-facial modules (Pack of 200)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003eA trade pack of 200 power optimisers.\u003c\/p\u003e\n      \u003cp\u003eThis listing supplies 200 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 200 x SolarEdge P1100 Optimizer 1100W MC4 2 x high power or bi-facial modules (\u003ca href=\"\/products\/P1100-2.4-MC4\"\u003eP1100-2.4-MC4\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout this pack\u003c\/h2\u003e\n    \u003cp\u003eThis listing supplies 200 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eDetails\u003c\/div\u003e\n    \u003ch2\u003eWhat this is\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eManufacturer\u003c\/span\u003e\u003cstrong\u003eSolarEdge\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePart number\u003c\/span\u003e\u003cstrong\u003eP1100-2.4-MC4-200\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eQuantity in this pack\u003c\/span\u003e\u003cstrong\u003e200\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eAny datasheets we hold are in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e, or email \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you need help.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440899432780,"sku":"P1100-2.4-MC4-200","price":14944.51,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/P1100-2.4-MC4-200.jpg?v=1778196024"},{"product_id":"p850-2-2-li-1-3-mc4-200","title":"P850 Optimiser 850W MC4 2x High Power\/Bi-facial 2.2m with 1.3m input length (Pack of 200)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · trade pack\u003c\/div\u003e\n    \u003ch2\u003eP850 Optimiser 850W MC4 2x High Power\/Bi-facial 2.2m with 1.3m input length (Pack of 200)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003eA trade pack of 200 power optimisers.\u003c\/p\u003e\n      \u003cp\u003eThis listing supplies 200 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 200 x P850 Optimiser 850W MC4 2x High Power\/Bi-facial 2.2m with 1.3m input length (\u003ca href=\"\/products\/P850-2.2-LI-1.3-MC4\"\u003eP850-2.2-LI-1.3-MC4\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout this pack\u003c\/h2\u003e\n    \u003cp\u003eThis listing supplies 200 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eDetails\u003c\/div\u003e\n    \u003ch2\u003eWhat this is\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eManufacturer\u003c\/span\u003e\u003cstrong\u003eSolarEdge\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePart number\u003c\/span\u003e\u003cstrong\u003eP850-2.2-LI-1.3-MC4-200\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eQuantity in this pack\u003c\/span\u003e\u003cstrong\u003e200\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eAny datasheets we hold are in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e, or email \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you need help.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440899563852,"sku":"P850-2.2-LI-1.3-MC4-200","price":13743.48,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/P850-2.2-LI-1.3-MC4-200.jpg?v=1778196025"},{"product_id":"s500-b-mc4-20","title":"Solar Edge S500B Power Optimizer MC4 (Pack of 20 = 2 Boxes)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · trade pack\u003c\/div\u003e\n    \u003ch2\u003eSolar Edge S500B Power Optimizer MC4 (Pack of 20 = 2 Boxes)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003eA trade pack of 20 power optimisers.\u003c\/p\u003e\n      \u003cp\u003eThis listing supplies 20 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 20 x Solar Edge S500B Power Optimizer (45mm Depth) (\u003ca href=\"\/products\/S500-B-MC4\"\u003eS500-B-MC4\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout this pack\u003c\/h2\u003e\n    \u003cp\u003eThis listing supplies 20 of the same part in one order, priced for installers and specifiers buying at volume. The individual product page carries the full specification, datasheets and certification.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eDetails\u003c\/div\u003e\n    \u003ch2\u003eWhat this is\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eManufacturer\u003c\/span\u003e\u003cstrong\u003eSolarEdge\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePart number\u003c\/span\u003e\u003cstrong\u003eS500-B-MC4-20\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eQuantity in this pack\u003c\/span\u003e\u003cstrong\u003e20\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered alongside this item\u003c\/h2\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b-mc4\"\u003eSolar Edge S500B Power Optimizer (45mm Depth)\u003c\/a\u003e\u003cspan\u003eThe same item as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eAny datasheets we hold are in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e, or email \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you need help.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440900022604,"sku":"S500-B-MC4-20","price":1286.21,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/S500-B-MC4-20.jpg?v=1778196032"},{"product_id":"se-10000h-net-3","title":"10,000W Home Wave Inverter - Single Phase (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Home Wave Single Phase, 8 – 10 kW\u003c\/div\u003e\n    \u003ch2\u003e10,000W Home Wave Inverter - Single Phase (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Home Wave Single Phase, 8 – 10 kW\u003c\/strong\u003e — The single-phase ceiling: 10 kW AC, 20 kW DC, 99 % weighted.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e10,000 VA\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e20,000 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 25 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 3 x 10,000W Home Wave Inverter - Single Phase (\u003ca href=\"\/products\/SE-10000H-NET\"\u003eSE-10000H-NET\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Home Wave Single Phase, 8 – 10 kW\u003c\/h2\u003e\n    \u003cp\u003eThis is the top of SolarEdge's single-phase Home Wave range for the UK, and it exists for houses whose electrical demand has outgrown a conventional domestic array — a heat pump, two EVs, a home office, or simply a very large roof.\u003c\/p\u003e\n    \u003cp\u003eThe specification that stands out is DC oversizing: 20,000 W of modules on a 10,000 W inverter. Because SolarEdge optimisers present a fixed voltage, that 200 % ratio is a supported design rather than an overload, and in UK light conditions the array spends almost all of its year below the clipping threshold anyway. You harvest far more in spring and autumn and lose a handful of hours at midsummer.\u003c\/p\u003e\n    \u003cp\u003eEuropean weighted efficiency is 99 %, which is about as good as grid-tied conversion gets, and it comes with the same module-level monitoring, SafeDC shutdown and integrated arc-fault protection as the rest of the range.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module.\u003c\/li\u003e\n        \u003cli\u003eThree MC4 pairs on the DC side. Nominal DC input 400 V, maximum 480 V.\u003c\/li\u003e\n        \u003cli\u003e45.5 A continuous output at 10 kW — check the consumer unit, the tails and the DNO position before you commit.\u003c\/li\u003e\n        \u003cli\u003eThis will be a G99 application on a single-phase supply, not a G98 notification.\u003c\/li\u003e\n        \u003cli\u003eCertified to G83\/1, G83\/2 and G59\/3 on the datasheet; check current G98\/G99 documentation for your application.\u003c\/li\u003e\n        \u003cli\u003e360 × 370 × 185 mm, 16.5 kg, IP65, natural convection, under 50 dBA.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Home Wave Single Phase, 8 – 10 kW is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eVery large domestic roofs\u003c\/strong\u003e\u003cspan\u003eWhere the array is 12 kWp or more and the supply is single phase.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eHeat pump plus EV households\u003c\/strong\u003e\u003cspan\u003eSized for a home that has electrified its heating and its driving.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eBarn conversions and large rural houses\u003c\/strong\u003e\u003cspan\u003eBig roof, single-phase supply.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eHeavily oversized DC arrays\u003c\/strong\u003e\u003cspan\u003e200 % DC\/AC is designed in, which suits UK irradiance.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded large roofs\u003c\/strong\u003e\u003cspan\u003eOptimiser architecture handles complex shading a string inverter cannot.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis inverter has a battery port. It takes \u003cstrong\u003eCompatible with SolarEdge Energy Bank, subject to inverter firmware support\u003c\/strong\u003e.\u003c\/p\u003e    \u003cdiv class=\"cr-warn\"\u003eBattery architecture is not interchangeable. A high-voltage inverter cannot use a 48 V low-voltage battery and vice versa, whatever a compatibility list says, so check the voltage before you order. If you are not certain, ask us and we will confirm it against your part number.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE10000H technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e20,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e25.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e10,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e10,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e45.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage (nominal)\u003c\/span\u003e\u003cstrong\u003e220 \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency (nominal)\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e1, adjustable −0.8 to 0.8\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e400 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e99.2 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e99 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2.5 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e600 kΩ sensitivity per unit\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp mobile application over built-in Wi-Fi access point\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485, Ethernet, ZigBee (optional), SolarEdge Home Network (optional), Wi-Fi (optional), cellular (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC input\u003c\/span\u003e\u003cstrong\u003e3 × MC4 pair\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003cstrong\u003e360 × 370 × 185 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e16.5 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNoise\u003c\/span\u003e\u003cstrong\u003e\u0026lt;50 dBA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating temperature range\u003c\/span\u003e\u003cstrong\u003e−40 °C to +60 °C, full power to at least +50 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG83\/1, G83\/2, G59\/3, RD 661, RD 1699, UTE C15-712\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 25 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SolarEdge Home Wave 8k-10k Net (DS-000119-ENG)\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b2-mc4\"\u003eSolar Edge S500B Power Optimizer (33mm Depth)\u003c\/a\u003e\u003cspan\u003eThe current residential power optimiser. One per module is required.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s650-b-mc4\"\u003eSolarEdge S650B Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe 650 W residential optimiser, for large-format modules.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I really put 20 kW of panels on a 10 kW inverter?\u003c\/summary\u003e\u003cp\u003eYes, that is the datasheet figure. In UK conditions an array rarely reaches its STC rating, so the clipping loss is small and the gains on dull days are large. Model it before committing, but do not be put off by the ratio.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWill the DNO allow 10 kW on single phase?\u003c\/summary\u003e\u003cp\u003eIt is a G99 application and the answer is network-specific. Many will approve it with an export limit. Apply early.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need optimisers?\u003c\/summary\u003e\u003cp\u003eYes, on every module. This is not a conventional string inverter.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eBattery?\u003c\/summary\u003e\u003cp\u003eThe datasheet lists the SolarEdge Energy Bank, subject to inverter firmware support. If storage is the goal from day one, the Home Hub inverter is the purpose-built choice — ask us and we will check your part number.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440901169484,"sku":"SE-10000H-NET-3","price":2742.76,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-10000H-NET-3.jpg?v=1778196042"},{"product_id":"se1000-rs485-if01-10","title":"SolarEdge RS485 Expansion Kit (Pack of 10)","description":"\u003cp\u003e\u003cstrong\u003eSolarEdge RS485 Expansion Kit (Pack of 10)\u003c\/strong\u003e is a monitoring accessory from SolarEdge, with a RS485 connection.\u003c\/p\u003e\n\u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 10 x SolarEdge RS485 Plug-in (\u003ca href=\"\/products\/SE1000-RS485-IF01\"\u003eSE1000-RS485-IF01\u003c\/a\u003e)\u003c\/div\u003e\n\u003cp\u003ePart of the monitoring and communication chain on a solar, battery or EV charging installation.\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSolarEdge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eSE1000-RS485-IF01-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003eDetailed electrical and mechanical data for this part is in the manufacturer's own documentation, in the Documents tab below where we hold it. If you need a figure that is not listed here, ask us and we will get it from the manufacturer rather than guess.\u003c\/p\u003e\n\u003cp\u003eDatasheets, installation manuals and declarations of conformity we hold for this product are in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/display\"\u003emonitoring and metering\u003c\/a\u003e range, or contact our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e for compatibility advice and trade pricing.\u003c\/p\u003e","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440901792076,"sku":"SE1000-RS485-IF01-10","price":387.59,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE1000-RS485-IF01-10.jpg?v=1778196047"},{"product_id":"se-16000-app-3","title":"SolarEdge 16,000W Three Phase Inverter NO DISPLAY (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Three Phase SE12.5K – SE27.6K\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge 16,000W Three Phase Inverter NO DISPLAY (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Three Phase SE12.5K – SE27.6K\u003c\/strong\u003e — The commercial mid-range, with an optional integrated DC safety unit.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e16,000 VA\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e21,600 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e1,000 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 3 x SolarEdge 16,000W Three Phase Inverter NO DISPLAY (\u003ca href=\"\/products\/SE-16000-APP\"\u003eSE-16000-APP\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Three Phase SE12.5K – SE27.6K\u003c\/h2\u003e\n    \u003cp\u003eThis is the size band where a solar project stops being domestic: 12.5 kW to 27.6 kW on three phase, for workshops, farms, small industrial units and large rural properties. The array is big enough that DC safety and diagnostics start to matter as much as efficiency.\u003c\/p\u003e\n    \u003cp\u003eThe optional integrated DC Safety Unit is the practical highlight. It puts the DC isolation inside the inverter enclosure, which removes a separate weatherproof box from the wall, a set of glands from the install and a failure point from the system. Optional DC surge protection and DC fuses go in the same place.\u003c\/p\u003e\n    \u003cp\u003eFixed-voltage operation at 750 V nominal, up to 1,000 V maximum, gives 98.3 % peak efficiency and long strings. Module-level monitoring comes as standard, which on a commercial roof is the difference between knowing a string is down and guessing.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module.\u003c\/li\u003e\n        \u003cli\u003e1,000 Vdc maximum input, fixed 750 Vdc nominal operation.\u003c\/li\u003e\n        \u003cli\u003eOptional integrated DC Safety Unit removes the need for external DC isolators.\u003c\/li\u003e\n        \u003cli\u003eOptional DC surge protection and DC fuses; optional rapid shutdown on SE25K and SE27.6K (part number SExxK-RWRxxxxxx).\u003c\/li\u003e\n        \u003cli\u003eIntegrated arc fault protection.\u003c\/li\u003e\n        \u003cli\u003eCommissioned with SolarEdge SetApp; IP65 for indoor or outdoor mounting.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Three Phase SE12.5K – SE27.6K is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eWorkshops and light industrial units\u003c\/strong\u003e\u003cspan\u003e12 kW to 27 kW covers most single-building commercial roofs.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eFarm buildings\u003c\/strong\u003e\u003cspan\u003eThree-phase rural supply and a large barn roof.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSchools and community buildings\u003c\/strong\u003e\u003cspan\u003eModule-level data suits reporting obligations on grant-funded schemes.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLarge rural houses\u003c\/strong\u003e\u003cspan\u003eWhere the array exceeds what the domestic range covers.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded or complex commercial roofs\u003c\/strong\u003e\u003cspan\u003ePlant, ducting and parapets shade commercial roofs far more than people expect.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThe SolarEdge SetApp mobile application is required to commission this inverter. There is no display; commissioning is done from a phone over the inverter's own Wi-Fi access point.\u003c\/li\u003e\n        \u003cli\u003eUK only: this inverter is tested and certified to G98 or G99 only with the most recent firmware version. Update the inverter firmware during the SetApp commissioning process, as set out in the installation manual.\u003c\/li\u003e\n        \u003cli\u003eThis inverter does not have a display. It is the new Comms Board version, and set-up and commissioning are done with the SolarEdge SetApp mobile application.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE16K technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e21,600 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e23 Adc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e16,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e16,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e25.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage — line to line \/ line to neutral (nominal)\u003c\/span\u003e\u003cstrong\u003e380 \/ 220; 400 \/ 230 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage — line to neutral range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrids supported\u003c\/span\u003e\u003cstrong\u003e3 \/ N \/ PE (WYE with neutral)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e750 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e700 kΩ sensitivity\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e98.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC Safety Unit\u003c\/span\u003e\u003cstrong\u003eOptional, integrated\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSolarEdge SetApp from a smartphone\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eSee the certification documents attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SE 15-27.6k Three Phase with Set APP\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-16000-app\"\u003eSolarEdge 16,000W Three Phase Inverter NO DISPLAY\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1000-mc4\"\u003eS1000 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two modules in series, short input lead.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1200-mc4\"\u003eS1200 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two high power or bifacial modules.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is the DC Safety Unit?\u003c\/summary\u003e\u003cp\u003eAn optional module integrated into the inverter that provides DC isolation, and can also carry DC surge protection and fuses. It replaces a separate external isolator enclosure, which saves an install step and removes a common water-ingress point.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is rapid shutdown for?\u003c\/summary\u003e\u003cp\u003eIt de-energises the array automatically when the AC grid disconnects. It is available on the SE25K and SE27.6K and is worth specifying where a fire officer or insurer asks for it.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need optimisers?\u003c\/summary\u003e\u003cp\u003eYes, on every module.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is the warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard, extendable to 20.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440902611276,"sku":"SE-16000-APP-3","price":3067.19,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-16000-APP-3.jpg?v=1778196058"},{"product_id":"se-17000-app-3","title":"SolarEdge 17,000W Three Phase Inverter NO DISPLAY (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Three Phase SE12.5K – SE27.6K\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge 17,000W Three Phase Inverter NO DISPLAY (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Three Phase SE12.5K – SE27.6K\u003c\/strong\u003e — The commercial mid-range, with an optional integrated DC safety unit.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e17,000 VA\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e22,950 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e1,000 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 3 x SolarEdge 17,000W Three Phase Inverter NO DISPLAY (\u003ca href=\"\/products\/SE-17000-APP\"\u003eSE-17000-APP\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Three Phase SE12.5K – SE27.6K\u003c\/h2\u003e\n    \u003cp\u003eThis is the size band where a solar project stops being domestic: 12.5 kW to 27.6 kW on three phase, for workshops, farms, small industrial units and large rural properties. The array is big enough that DC safety and diagnostics start to matter as much as efficiency.\u003c\/p\u003e\n    \u003cp\u003eThe optional integrated DC Safety Unit is the practical highlight. It puts the DC isolation inside the inverter enclosure, which removes a separate weatherproof box from the wall, a set of glands from the install and a failure point from the system. Optional DC surge protection and DC fuses go in the same place.\u003c\/p\u003e\n    \u003cp\u003eFixed-voltage operation at 750 V nominal, up to 1,000 V maximum, gives 98.3 % peak efficiency and long strings. Module-level monitoring comes as standard, which on a commercial roof is the difference between knowing a string is down and guessing.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module.\u003c\/li\u003e\n        \u003cli\u003e1,000 Vdc maximum input, fixed 750 Vdc nominal operation.\u003c\/li\u003e\n        \u003cli\u003eOptional integrated DC Safety Unit removes the need for external DC isolators.\u003c\/li\u003e\n        \u003cli\u003eOptional DC surge protection and DC fuses; optional rapid shutdown on SE25K and SE27.6K (part number SExxK-RWRxxxxxx).\u003c\/li\u003e\n        \u003cli\u003eIntegrated arc fault protection.\u003c\/li\u003e\n        \u003cli\u003eCommissioned with SolarEdge SetApp; IP65 for indoor or outdoor mounting.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Three Phase SE12.5K – SE27.6K is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eWorkshops and light industrial units\u003c\/strong\u003e\u003cspan\u003e12 kW to 27 kW covers most single-building commercial roofs.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eFarm buildings\u003c\/strong\u003e\u003cspan\u003eThree-phase rural supply and a large barn roof.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSchools and community buildings\u003c\/strong\u003e\u003cspan\u003eModule-level data suits reporting obligations on grant-funded schemes.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLarge rural houses\u003c\/strong\u003e\u003cspan\u003eWhere the array exceeds what the domestic range covers.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded or complex commercial roofs\u003c\/strong\u003e\u003cspan\u003ePlant, ducting and parapets shade commercial roofs far more than people expect.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThe SolarEdge SetApp mobile application is required to commission this inverter. There is no display; commissioning is done from a phone over the inverter's own Wi-Fi access point.\u003c\/li\u003e\n        \u003cli\u003eUK only: this inverter is tested and certified to G98 or G99 only with the most recent firmware version. Update the inverter firmware during the SetApp commissioning process, as set out in the installation manual.\u003c\/li\u003e\n        \u003cli\u003eThis inverter does not have a display. It is the new Comms Board version, and set-up and commissioning are done with the SolarEdge SetApp mobile application.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE17K technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e22,950 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e23 Adc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e17,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e17,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e26 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage — line to line \/ line to neutral (nominal)\u003c\/span\u003e\u003cstrong\u003e380 \/ 220; 400 \/ 230 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage — line to neutral range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrids supported\u003c\/span\u003e\u003cstrong\u003e3 \/ N \/ PE (WYE with neutral)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e750 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e700 kΩ sensitivity\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e98.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC Safety Unit\u003c\/span\u003e\u003cstrong\u003eOptional, integrated\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSolarEdge SetApp from a smartphone\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eSee the certification documents attached to this listing\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SE 15-27.6k Three Phase with Set APP\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-17000-app\"\u003eSolarEdge 17,000W Three Phase Inverter NO DISPLAY\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1000-mc4\"\u003eS1000 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two modules in series, short input lead.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1200-mc4\"\u003eS1200 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two high power or bifacial modules.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is the DC Safety Unit?\u003c\/summary\u003e\u003cp\u003eAn optional module integrated into the inverter that provides DC isolation, and can also carry DC surge protection and fuses. It replaces a separate external isolator enclosure, which saves an install step and removes a common water-ingress point.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is rapid shutdown for?\u003c\/summary\u003e\u003cp\u003eIt de-energises the array automatically when the AC grid disconnects. It is available on the SE25K and SE27.6K and is worth specifying where a fire officer or insurer asks for it.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need optimisers?\u003c\/summary\u003e\u003cp\u003eYes, on every module.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is the warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard, extendable to 20.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440902873420,"sku":"SE-17000-APP-3","price":3110.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-17000-APP-3.jpg?v=1778196062"},{"product_id":"se-2200h-net-5","title":"2200W Home Wave 1PH Inverter (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Home Wave Single Phase\u003c\/div\u003e\n    \u003ch2\u003e2200W Home Wave 1PH Inverter (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Home Wave Single Phase\u003c\/strong\u003e — HD-Wave, 99 % weighted efficiency, and a panel-by-panel view of your roof.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e2,200 VA\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e4,400 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 25 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x 2,200W Home Wave Inverter - Single Phase (\u003ca href=\"\/products\/SE-2200H-NET\"\u003eSE-2200H-NET\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Home Wave Single Phase\u003c\/h2\u003e\n    \u003cp\u003eA SolarEdge system is a different architecture from a conventional string inverter, and the difference is worth understanding before you choose one. Every panel gets its own power optimiser, which tracks that panel's maximum power point individually and hands the inverter a fixed, well-behaved DC voltage. The inverter then has one job — convert — and it does it at up to 99 % European weighted efficiency, one of the highest figures available anywhere.\u003c\/p\u003e\n    \u003cp\u003eWhat that architecture buys you in practice is threefold. Shading on one panel stops mattering to the rest of the string. String lengths become far more flexible, because the inverter always sees the same voltage. And you get module-level monitoring as standard: the app shows you each panel, so a fault is a specific panel on a specific row rather than a number that looks a bit low.\u003c\/p\u003e\n    \u003cp\u003eThe HD-Wave topology is what makes this range so light and compact for its output — 280 × 370 × 142 mm and IP65, indoors or out, with no external fan. There is a safety dividend as well: SafeDC drops the array's DC voltage to a touch-safe level automatically whenever the inverter or the grid shuts down, and integrated arc-fault protection is built in.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module — this is not a conventional string inverter and will not work without them.\u003c\/li\u003e\n        \u003cli\u003eFixed 380 V nominal DC input, 480 V maximum, so string design is about optimiser count rather than module Voc at temperature.\u003c\/li\u003e\n        \u003cli\u003e200 % DC oversizing supported.\u003c\/li\u003e\n        \u003cli\u003eCommissioned from a phone with SolarEdge SetApp over the inverter's built-in Wi-Fi access point — no display to pay for or fail.\u003c\/li\u003e\n        \u003cli\u003eIntegrated arc-fault protection to UL 1699B, user configurable.\u003c\/li\u003e\n        \u003cli\u003eCertified to G98 and G99, EN 50438, VDE-AR-N-4105 and IEC 61727\/62116.\u003c\/li\u003e\n        \u003cli\u003eConnects to the SolarEdge Home Battery and other Home ecosystem devices over the optional SolarEdge Home Network.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Home Wave Single Phase is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded and complex roofs\u003c\/strong\u003e\u003cspan\u003eThe single strongest reason to choose SolarEdge over a string inverter.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-orientation arrays\u003c\/strong\u003e\u003cspan\u003ePanels on three or four planes on one inverter, all optimised individually.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRoofs with awkward panel counts\u003c\/strong\u003e\u003cspan\u003eFixed-voltage architecture removes most string-length constraints.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCustomers who want per-panel data\u003c\/strong\u003e\u003cspan\u003eModule-level monitoring is standard, not an add-on.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eStorage-ready installs\u003c\/strong\u003e\u003cspan\u003eAdd the SolarEdge Home Battery later over the Home Network.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-term asset owners\u003c\/strong\u003e\u003cspan\u003e12-year warranty as standard, extendable to 25.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis inverter has a battery port. It takes \u003cstrong\u003eReady for the SolarEdge Home Battery over the SolarEdge Home Network\u003c\/strong\u003e.\u003c\/p\u003e    \u003cdiv class=\"cr-warn\"\u003eBattery architecture is not interchangeable. A high-voltage inverter cannot use a 48 V low-voltage battery and vice versa, whatever a compatibility list says, so check the voltage before you order. If you are not certain, ask us and we will confirm it against your part number.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE2200H technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e4,400 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e6.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e2,200 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e2,200 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e10 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC input\u003c\/span\u003e\u003cstrong\u003e1 × MC4 pair\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage (nominal)\u003c\/span\u003e\u003cstrong\u003e220 \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency (nominal)\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e1, adjustable −0.9 to 0.9\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e380 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e600 kΩ sensitivity per unit\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e99.2 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2.5 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp mobile application over built-in Wi-Fi\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485, Ethernet, Wi-Fi (optional), SolarEdge Home Network (optional), cellular (optional), ZigBee (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003cstrong\u003e280 × 370 × 142 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output supported cable diameter\u003c\/span\u003e\u003cstrong\u003e9 – 16 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC supported wire cross section\u003c\/span\u003e\u003cstrong\u003e1 – 13 mm²\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eIEC 61727, IEC 62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE C 15-712, G98, G99, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109-1\/2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 25 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SolarEdge Home Wave 1PH 2.2-6kW EU \/ Home Wave 2.2k-6k NET\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-2200h-net\"\u003e2,200W Home Wave Inverter - Single Phase\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b2-mc4\"\u003eSolar Edge S500B Power Optimizer (33mm Depth)\u003c\/a\u003e\u003cspan\u003eThe current residential power optimiser. One per module is required.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s440-mc4\"\u003eSolar Edge S440 Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe smaller residential optimiser, for modules up to 490 W.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I have to buy optimisers as well?\u003c\/summary\u003e\u003cp\u003eYes. A SolarEdge inverter needs a SolarEdge power optimiser behind every module. Budget for both. The upside is that the optimisers carry a 25-year warranty and do the shade mitigation, string flexibility and per-panel monitoring.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it worth it over a normal string inverter?\u003c\/summary\u003e\u003cp\u003eOn a clean, single-orientation, unshaded roof, often not — a good dual-tracker string inverter costs less and performs similarly. On a shaded, multi-pitch or complex roof, the difference in annual yield is usually decisive.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is SafeDC?\u003c\/summary\u003e\u003cp\u003eWhen the inverter or grid shuts down, each optimiser drops its output to about 1 V, so the array's DC cabling falls to a touch-safe voltage instead of sitting at several hundred volts. It is a genuine safety feature for installers and for the fire service.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard on the inverter, extendable to 25. Optimisers are 25 years as standard.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery?\u003c\/summary\u003e\u003cp\u003eYes — the SolarEdge Home Battery, connected over the SolarEdge Home Network. Note that the specific battery model depends on the inverter; ask us to check your part number before ordering.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs there a display?\u003c\/summary\u003e\u003cp\u003eNo, and deliberately so. Commissioning and monitoring are done through SetApp and the mySolarEdge app, which removes a component that historically failed.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440906674508,"sku":"SE-2200H-NET-5","price":1862.32,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-2200H-NET-5.jpg?v=1778196066"},{"product_id":"se-25000-r4-app-3","title":"SolarEdge 25,000W Three Phase Inverter D4 with DC Safety Unit and fuses NO DISPLAY (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Three Phase Commercial SE20K – SE33.3K\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge 25,000W Three Phase Inverter D4 with DC Safety Unit and fuses NO DISPLAY (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Three Phase Commercial SE20K – SE33.3K\u003c\/strong\u003e — 20 kW to 33.3 kW, with integrated Type II DC surge protection as standard.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e25,000 W\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e43,750 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.3 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 3 x SolarEdge 25,000W Three Phase Inverter R4 with DC Safety Unit and fuses NO DISPLAY (\u003ca href=\"\/products\/SE-25000-R4-APP\"\u003eSE-25000-R4-APP\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Three Phase Commercial SE20K – SE33.3K\u003c\/h2\u003e\n    \u003cp\u003eThis is SolarEdge's core commercial three-phase range and the one that turns up on most UK industrial roofs in the 20 kW to 33 kW band. It runs at a fixed 680 – 1,000 V operating window with a 1,000 V maximum, which gives long strings and 98.3 % peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eTwo things distinguish it from the ranges below. Type II DC surge protection is integrated and field replaceable as standard, not an option — on an exposed commercial roof with long DC runs, that is the component that quietly earns its keep during a summer storm. And the optional DC Safety Unit provides 1,000 V \/ 48.25 A two-pole disconnection with optional 25 A or 30 A single-pole DC fuses inside the same enclosure.\u003c\/p\u003e\n    \u003cp\u003eRapid shutdown is available as an option, triggering automatically on AC grid disconnect. Combined with SafeDC at the optimiser and integrated arc-fault protection, that gives a DC safety story most commercial insurers are comfortable with.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module.\u003c\/li\u003e\n        \u003cli\u003e1,000 Vdc maximum, 680 – 1,000 Vdc operating window.\u003c\/li\u003e\n        \u003cli\u003eType II DC surge protection integrated and field replaceable as standard; AC Type II optional.\u003c\/li\u003e\n        \u003cli\u003eOptional DC Safety Unit: 1,000 V \/ 48.25 A two-pole disconnection, optional 25 A \/ 30 A DC fuses, UTE-C15-712-1 compliant.\u003c\/li\u003e\n        \u003cli\u003eOptional rapid shutdown (part numbers SExxK-xxRxxxxxx), automatic on AC grid disconnect.\u003c\/li\u003e\n        \u003cli\u003eTwo RS485 ports plus Ethernet; Wi-Fi and cellular optional.\u003c\/li\u003e\n        \u003cli\u003eNote for German sites under VDE-AR-N-4110: the SE33.3K counts as a 30 kW inverter for site capacity, and current limits differ — check the datasheet footnotes.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Three Phase Commercial SE20K – SE33.3K is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eIndustrial and warehouse roofs\u003c\/strong\u003e\u003cspan\u003eThe volume size band for UK commercial rooftop solar.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eAgricultural buildings\u003c\/strong\u003e\u003cspan\u003eLarge barn roofs on three-phase supplies.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-building commercial sites\u003c\/strong\u003e\u003cspan\u003eOne inverter per building, all in one monitoring portal.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRetail parks and distribution\u003c\/strong\u003e\u003cspan\u003eDaytime load matched to generation.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites needing rapid shutdown\u003c\/strong\u003e\u003cspan\u003eWhere the fire officer or the insurer asks for automatic DC de-energisation.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded or plant-cluttered roofs\u003c\/strong\u003e\u003cspan\u003eOptimisers handle the shading commercial roofs always turn out to have.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThe SolarEdge SetApp mobile application is required to commission this inverter. There is no display; commissioning is done from a phone over the inverter's own Wi-Fi access point.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE25K technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e43,750 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e36.25 Adc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e25,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e25,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e36.25 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage — line to line \/ line to neutral (nominal)\u003c\/span\u003e\u003cstrong\u003e380 \/ 220; 400 \/ 230 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e304 – 437 \/ 176 – 253; 320 – 460 \/ 184 – 264.5 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output line connections\u003c\/span\u003e\u003cstrong\u003e3W + PE, 4W + PE\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor range\u003c\/span\u003e\u003cstrong\u003e±0.2 to 1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum residual current injection\u003c\/span\u003e\u003cstrong\u003e100 mA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage DC+ to DC−\u003c\/span\u003e\u003cstrong\u003e1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating voltage range\u003c\/span\u003e\u003cstrong\u003e680 – 1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e167 kΩ sensitivity\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;4 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003e2 × RS485, Ethernet, Wi-Fi (optional), cellular (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp over the built-in Wi-Fi access point\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRapid shutdown\u003c\/span\u003e\u003cstrong\u003eOptional, automatic on AC grid disconnect\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC surge protection\u003c\/span\u003e\u003cstrong\u003eType II, field replaceable, integrated\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC surge protection\u003c\/span\u003e\u003cstrong\u003eType II, field replaceable, optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC Safety Unit (optional)\u003c\/span\u003e\u003cstrong\u003eTwo-pole disconnection 1,000 V \/ 48.25 A; optional single-pole 25 A \/ 30 A DC fuses; UTE-C15-712-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRoHS\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eVDE-AR-N-4105, VDE-AR-N-4110, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, EN 50549-1, EN 50549-2, TOR Erzeuger Typ A, G99, G99 (NI), VFR 2019\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109, AS 3100\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eSolarEdge Three Phase Commercial Inverter for Europe, DS-000053-EU dated 17 June 2024\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1000-mc4\"\u003eS1000 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two modules in series, short input lead.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1200-mc4\"\u003eS1200 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two high power or bifacial modules.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1000-li-mc4\"\u003eS1000 Power Optimizer Long Input (1.3m)\u003c\/a\u003e\u003cspan\u003eThe same S1000 with a 1.3 m long input lead.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs DC surge protection really needed?\u003c\/summary\u003e\u003cp\u003eOn a commercial roof with hundreds of metres of DC cable, yes. Induced surges from nearby lightning are a leading cause of inverter failure on large arrays. Here it is fitted as standard and it is field replaceable, so a hit costs a part rather than an inverter.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does the DC Safety Unit include?\u003c\/summary\u003e\u003cp\u003eTwo-pole DC disconnection rated 1,000 V \/ 48.25 A, with optional single-pole 25 A or 30 A DC fuses, integrated into the inverter enclosure and compliant with UTE-C15-712-1.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need optimisers?\u003c\/summary\u003e\u003cp\u003eYes, on every module.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I export limit?\u003c\/summary\u003e\u003cp\u003eYes, export limitation is part of the smart energy management feature set, and G99 is on the certification list.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is the warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard, extendable to 20.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440907002188,"sku":"SE-25000-R4-APP-3","price":5488.4,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-25000-R4-APP-3.jpg?v=1778196069"},{"product_id":"se-25000-spd-rsd-3","title":"SolarEdge 25000W Three Phase inverter With DC Safety Unit, SPD II, Rapid Shutdown Device (Pack of 3","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Three Phase Commercial SE20K – SE33.3K\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge 25000W Three Phase inverter With DC Safety Unit, SPD II, Rapid Shutdown Device (Pack of 3\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Three Phase Commercial SE20K – SE33.3K\u003c\/strong\u003e — 20 kW to 33.3 kW, with integrated Type II DC surge protection as standard.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e25,000 W\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e43,750 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.3 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 3 x SolarEdge 25,000W Three Phase inverter Z4 With DC Safety Unit, SPD II, Rapid Shutdown Device (\u003ca href=\"\/products\/SE-25000-SPD-RSD\"\u003eSE-25000-SPD-RSD\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Three Phase Commercial SE20K – SE33.3K\u003c\/h2\u003e\n    \u003cp\u003eThis is SolarEdge's core commercial three-phase range and the one that turns up on most UK industrial roofs in the 20 kW to 33 kW band. It runs at a fixed 680 – 1,000 V operating window with a 1,000 V maximum, which gives long strings and 98.3 % peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eTwo things distinguish it from the ranges below. Type II DC surge protection is integrated and field replaceable as standard, not an option — on an exposed commercial roof with long DC runs, that is the component that quietly earns its keep during a summer storm. And the optional DC Safety Unit provides 1,000 V \/ 48.25 A two-pole disconnection with optional 25 A or 30 A single-pole DC fuses inside the same enclosure.\u003c\/p\u003e\n    \u003cp\u003eRapid shutdown is available as an option, triggering automatically on AC grid disconnect. Combined with SafeDC at the optimiser and integrated arc-fault protection, that gives a DC safety story most commercial insurers are comfortable with.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module.\u003c\/li\u003e\n        \u003cli\u003e1,000 Vdc maximum, 680 – 1,000 Vdc operating window.\u003c\/li\u003e\n        \u003cli\u003eType II DC surge protection integrated and field replaceable as standard; AC Type II optional.\u003c\/li\u003e\n        \u003cli\u003eOptional DC Safety Unit: 1,000 V \/ 48.25 A two-pole disconnection, optional 25 A \/ 30 A DC fuses, UTE-C15-712-1 compliant.\u003c\/li\u003e\n        \u003cli\u003eOptional rapid shutdown (part numbers SExxK-xxRxxxxxx), automatic on AC grid disconnect.\u003c\/li\u003e\n        \u003cli\u003eTwo RS485 ports plus Ethernet; Wi-Fi and cellular optional.\u003c\/li\u003e\n        \u003cli\u003eNote for German sites under VDE-AR-N-4110: the SE33.3K counts as a 30 kW inverter for site capacity, and current limits differ — check the datasheet footnotes.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Three Phase Commercial SE20K – SE33.3K is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eIndustrial and warehouse roofs\u003c\/strong\u003e\u003cspan\u003eThe volume size band for UK commercial rooftop solar.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eAgricultural buildings\u003c\/strong\u003e\u003cspan\u003eLarge barn roofs on three-phase supplies.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-building commercial sites\u003c\/strong\u003e\u003cspan\u003eOne inverter per building, all in one monitoring portal.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRetail parks and distribution\u003c\/strong\u003e\u003cspan\u003eDaytime load matched to generation.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites needing rapid shutdown\u003c\/strong\u003e\u003cspan\u003eWhere the fire officer or the insurer asks for automatic DC de-energisation.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded or plant-cluttered roofs\u003c\/strong\u003e\u003cspan\u003eOptimisers handle the shading commercial roofs always turn out to have.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE25K technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e43,750 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e36.25 Adc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e25,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e25,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e36.25 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage — line to line \/ line to neutral (nominal)\u003c\/span\u003e\u003cstrong\u003e380 \/ 220; 400 \/ 230 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e304 – 437 \/ 176 – 253; 320 – 460 \/ 184 – 264.5 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output line connections\u003c\/span\u003e\u003cstrong\u003e3W + PE, 4W + PE\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor range\u003c\/span\u003e\u003cstrong\u003e±0.2 to 1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum residual current injection\u003c\/span\u003e\u003cstrong\u003e100 mA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage DC+ to DC−\u003c\/span\u003e\u003cstrong\u003e1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating voltage range\u003c\/span\u003e\u003cstrong\u003e680 – 1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e167 kΩ sensitivity\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;4 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003e2 × RS485, Ethernet, Wi-Fi (optional), cellular (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp over the built-in Wi-Fi access point\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRapid shutdown\u003c\/span\u003e\u003cstrong\u003eOptional, automatic on AC grid disconnect\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC surge protection\u003c\/span\u003e\u003cstrong\u003eType II, field replaceable, integrated\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC surge protection\u003c\/span\u003e\u003cstrong\u003eType II, field replaceable, optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC Safety Unit (optional)\u003c\/span\u003e\u003cstrong\u003eTwo-pole disconnection 1,000 V \/ 48.25 A; optional single-pole 25 A \/ 30 A DC fuses; UTE-C15-712-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRoHS\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eVDE-AR-N-4105, VDE-AR-N-4110, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, EN 50549-1, EN 50549-2, TOR Erzeuger Typ A, G99, G99 (NI), VFR 2019\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109, AS 3100\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eSolarEdge Three Phase Commercial Inverter for Europe, DS-000053-EU dated 17 June 2024\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1000-mc4\"\u003eS1000 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two modules in series, short input lead.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1200-mc4\"\u003eS1200 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two high power or bifacial modules.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1000-li-mc4\"\u003eS1000 Power Optimizer Long Input (1.3m)\u003c\/a\u003e\u003cspan\u003eThe same S1000 with a 1.3 m long input lead.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs DC surge protection really needed?\u003c\/summary\u003e\u003cp\u003eOn a commercial roof with hundreds of metres of DC cable, yes. Induced surges from nearby lightning are a leading cause of inverter failure on large arrays. Here it is fitted as standard and it is field replaceable, so a hit costs a part rather than an inverter.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does the DC Safety Unit include?\u003c\/summary\u003e\u003cp\u003eTwo-pole DC disconnection rated 1,000 V \/ 48.25 A, with optional single-pole 25 A or 30 A DC fuses, integrated into the inverter enclosure and compliant with UTE-C15-712-1.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need optimisers?\u003c\/summary\u003e\u003cp\u003eYes, on every module.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I export limit?\u003c\/summary\u003e\u003cp\u003eYes, export limitation is part of the smart energy management feature set, and G99 is on the certification list.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is the warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard, extendable to 20.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440907067724,"sku":"SE-25000-SPD-RSD-3","price":6801.4,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-25000-SPD-RSD-3.jpg?v=1778196070"},{"product_id":"se-30000-app-3","title":"SolarEdge 30,000W Three Phase Inverter DC SPD - NO DISPLAY (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Three Phase Commercial SE20K – SE33.3K\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge 30,000W Three Phase Inverter DC SPD - NO DISPLAY (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Three Phase Commercial SE20K – SE33.3K\u003c\/strong\u003e — 20 kW to 33.3 kW, with integrated Type II DC surge protection as standard.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e29,990 W\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e52,500 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.3 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 3 x SolarEdge 30,000W Three Phase Inverter M4 Basic NO DISPLAY (\u003ca href=\"\/products\/SE-30000-APP\"\u003eSE-30000-APP\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Three Phase Commercial SE20K – SE33.3K\u003c\/h2\u003e\n    \u003cp\u003eThis is SolarEdge's core commercial three-phase range and the one that turns up on most UK industrial roofs in the 20 kW to 33 kW band. It runs at a fixed 680 – 1,000 V operating window with a 1,000 V maximum, which gives long strings and 98.3 % peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eTwo things distinguish it from the ranges below. Type II DC surge protection is integrated and field replaceable as standard, not an option — on an exposed commercial roof with long DC runs, that is the component that quietly earns its keep during a summer storm. And the optional DC Safety Unit provides 1,000 V \/ 48.25 A two-pole disconnection with optional 25 A or 30 A single-pole DC fuses inside the same enclosure.\u003c\/p\u003e\n    \u003cp\u003eRapid shutdown is available as an option, triggering automatically on AC grid disconnect. Combined with SafeDC at the optimiser and integrated arc-fault protection, that gives a DC safety story most commercial insurers are comfortable with.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module.\u003c\/li\u003e\n        \u003cli\u003e1,000 Vdc maximum, 680 – 1,000 Vdc operating window.\u003c\/li\u003e\n        \u003cli\u003eType II DC surge protection integrated and field replaceable as standard; AC Type II optional.\u003c\/li\u003e\n        \u003cli\u003eOptional DC Safety Unit: 1,000 V \/ 48.25 A two-pole disconnection, optional 25 A \/ 30 A DC fuses, UTE-C15-712-1 compliant.\u003c\/li\u003e\n        \u003cli\u003eOptional rapid shutdown (part numbers SExxK-xxRxxxxxx), automatic on AC grid disconnect.\u003c\/li\u003e\n        \u003cli\u003eTwo RS485 ports plus Ethernet; Wi-Fi and cellular optional.\u003c\/li\u003e\n        \u003cli\u003eNote for German sites under VDE-AR-N-4110: the SE33.3K counts as a 30 kW inverter for site capacity, and current limits differ — check the datasheet footnotes.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Three Phase Commercial SE20K – SE33.3K is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eIndustrial and warehouse roofs\u003c\/strong\u003e\u003cspan\u003eThe volume size band for UK commercial rooftop solar.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eAgricultural buildings\u003c\/strong\u003e\u003cspan\u003eLarge barn roofs on three-phase supplies.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-building commercial sites\u003c\/strong\u003e\u003cspan\u003eOne inverter per building, all in one monitoring portal.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRetail parks and distribution\u003c\/strong\u003e\u003cspan\u003eDaytime load matched to generation.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites needing rapid shutdown\u003c\/strong\u003e\u003cspan\u003eWhere the fire officer or the insurer asks for automatic DC de-energisation.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded or plant-cluttered roofs\u003c\/strong\u003e\u003cspan\u003eOptimisers handle the shading commercial roofs always turn out to have.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThe SolarEdge SetApp mobile application is required to commission this inverter. There is no display; commissioning is done from a phone over the inverter's own Wi-Fi access point.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE30K technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e52,500 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e43.5 Adc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e29,990 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e29,990 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e43.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage — line to line \/ line to neutral (nominal)\u003c\/span\u003e\u003cstrong\u003e380 \/ 220; 400 \/ 230 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e304 – 437 \/ 176 – 253; 320 – 460 \/ 184 – 264.5 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output line connections\u003c\/span\u003e\u003cstrong\u003e3W + PE, 4W + PE\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor range\u003c\/span\u003e\u003cstrong\u003e±0.2 to 1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum residual current injection\u003c\/span\u003e\u003cstrong\u003e100 mA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage DC+ to DC−\u003c\/span\u003e\u003cstrong\u003e1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating voltage range\u003c\/span\u003e\u003cstrong\u003e680 – 1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e167 kΩ sensitivity\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;4 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003e2 × RS485, Ethernet, Wi-Fi (optional), cellular (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp over the built-in Wi-Fi access point\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRapid shutdown\u003c\/span\u003e\u003cstrong\u003eOptional, automatic on AC grid disconnect\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC surge protection\u003c\/span\u003e\u003cstrong\u003eType II, field replaceable, integrated\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC surge protection\u003c\/span\u003e\u003cstrong\u003eType II, field replaceable, optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC Safety Unit (optional)\u003c\/span\u003e\u003cstrong\u003eTwo-pole disconnection 1,000 V \/ 48.25 A; optional single-pole 25 A \/ 30 A DC fuses; UTE-C15-712-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRoHS\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eVDE-AR-N-4105, VDE-AR-N-4110, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, EN 50549-1, EN 50549-2, TOR Erzeuger Typ A, G99, G99 (NI), VFR 2019\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109, AS 3100\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eSolarEdge Three Phase Commercial Inverter for Europe, DS-000053-EU dated 17 June 2024\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1000-mc4\"\u003eS1000 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two modules in series, short input lead.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1200-mc4\"\u003eS1200 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two high power or bifacial modules.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1000-li-mc4\"\u003eS1000 Power Optimizer Long Input (1.3m)\u003c\/a\u003e\u003cspan\u003eThe same S1000 with a 1.3 m long input lead.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs DC surge protection really needed?\u003c\/summary\u003e\u003cp\u003eOn a commercial roof with hundreds of metres of DC cable, yes. Induced surges from nearby lightning are a leading cause of inverter failure on large arrays. Here it is fitted as standard and it is field replaceable, so a hit costs a part rather than an inverter.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does the DC Safety Unit include?\u003c\/summary\u003e\u003cp\u003eTwo-pole DC disconnection rated 1,000 V \/ 48.25 A, with optional single-pole 25 A or 30 A DC fuses, integrated into the inverter enclosure and compliant with UTE-C15-712-1.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need optimisers?\u003c\/summary\u003e\u003cp\u003eYes, on every module.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I export limit?\u003c\/summary\u003e\u003cp\u003eYes, export limitation is part of the smart energy management feature set, and G99 is on the certification list.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is the warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard, extendable to 20.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440907264332,"sku":"SE-30000-APP-3","price":4025.14,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-30000-APP-3.jpg?v=1778196074"},{"product_id":"se-3000h-net-5","title":"3,000W Home Wave 1PH Inverter  (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Home Wave Single Phase\u003c\/div\u003e\n    \u003ch2\u003e3,000W Home Wave 1PH Inverter  (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Home Wave Single Phase\u003c\/strong\u003e — HD-Wave, 99 % weighted efficiency, and a panel-by-panel view of your roof.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e3,000 VA\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e6,000 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 25 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x 3,000W Home Wave Inverter - Single Phase (\u003ca href=\"\/products\/SE-3000H-NET\"\u003eSE-3000H-NET\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Home Wave Single Phase\u003c\/h2\u003e\n    \u003cp\u003eA SolarEdge system is a different architecture from a conventional string inverter, and the difference is worth understanding before you choose one. Every panel gets its own power optimiser, which tracks that panel's maximum power point individually and hands the inverter a fixed, well-behaved DC voltage. The inverter then has one job — convert — and it does it at up to 99 % European weighted efficiency, one of the highest figures available anywhere.\u003c\/p\u003e\n    \u003cp\u003eWhat that architecture buys you in practice is threefold. Shading on one panel stops mattering to the rest of the string. String lengths become far more flexible, because the inverter always sees the same voltage. And you get module-level monitoring as standard: the app shows you each panel, so a fault is a specific panel on a specific row rather than a number that looks a bit low.\u003c\/p\u003e\n    \u003cp\u003eThe HD-Wave topology is what makes this range so light and compact for its output — 280 × 370 × 142 mm and IP65, indoors or out, with no external fan. There is a safety dividend as well: SafeDC drops the array's DC voltage to a touch-safe level automatically whenever the inverter or the grid shuts down, and integrated arc-fault protection is built in.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module — this is not a conventional string inverter and will not work without them.\u003c\/li\u003e\n        \u003cli\u003eFixed 380 V nominal DC input, 480 V maximum, so string design is about optimiser count rather than module Voc at temperature.\u003c\/li\u003e\n        \u003cli\u003e200 % DC oversizing supported.\u003c\/li\u003e\n        \u003cli\u003eCommissioned from a phone with SolarEdge SetApp over the inverter's built-in Wi-Fi access point — no display to pay for or fail.\u003c\/li\u003e\n        \u003cli\u003eIntegrated arc-fault protection to UL 1699B, user configurable.\u003c\/li\u003e\n        \u003cli\u003eCertified to G98 and G99, EN 50438, VDE-AR-N-4105 and IEC 61727\/62116.\u003c\/li\u003e\n        \u003cli\u003eConnects to the SolarEdge Home Battery and other Home ecosystem devices over the optional SolarEdge Home Network.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Home Wave Single Phase is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded and complex roofs\u003c\/strong\u003e\u003cspan\u003eThe single strongest reason to choose SolarEdge over a string inverter.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-orientation arrays\u003c\/strong\u003e\u003cspan\u003ePanels on three or four planes on one inverter, all optimised individually.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRoofs with awkward panel counts\u003c\/strong\u003e\u003cspan\u003eFixed-voltage architecture removes most string-length constraints.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCustomers who want per-panel data\u003c\/strong\u003e\u003cspan\u003eModule-level monitoring is standard, not an add-on.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eStorage-ready installs\u003c\/strong\u003e\u003cspan\u003eAdd the SolarEdge Home Battery later over the Home Network.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-term asset owners\u003c\/strong\u003e\u003cspan\u003e12-year warranty as standard, extendable to 25.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis inverter has a battery port. It takes \u003cstrong\u003eReady for the SolarEdge Home Battery over the SolarEdge Home Network\u003c\/strong\u003e.\u003c\/p\u003e    \u003cdiv class=\"cr-warn\"\u003eBattery architecture is not interchangeable. A high-voltage inverter cannot use a 48 V low-voltage battery and vice versa, whatever a compatibility list says, so check the voltage before you order. If you are not certain, ask us and we will confirm it against your part number.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThis inverter does not have a display. Commissioning is carried out through the SolarEdge SetApp.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE3000H technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e6,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e9 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e3,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e3,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e14 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98.8 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC input\u003c\/span\u003e\u003cstrong\u003e1 × MC4 pair\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage (nominal)\u003c\/span\u003e\u003cstrong\u003e220 \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency (nominal)\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e1, adjustable −0.9 to 0.9\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e380 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e600 kΩ sensitivity per unit\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e99.2 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2.5 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp mobile application over built-in Wi-Fi\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485, Ethernet, Wi-Fi (optional), SolarEdge Home Network (optional), cellular (optional), ZigBee (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003cstrong\u003e280 × 370 × 142 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output supported cable diameter\u003c\/span\u003e\u003cstrong\u003e9 – 16 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC supported wire cross section\u003c\/span\u003e\u003cstrong\u003e1 – 13 mm²\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eIEC 61727, IEC 62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE C 15-712, G98, G99, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109-1\/2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 25 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SolarEdge Home Wave 1PH 2.2-6kW EU \/ Home Wave 2.2k-6k NET\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-3000h-net\"\u003e3,000W Home Wave Inverter - Single Phase\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b2-mc4\"\u003eSolar Edge S500B Power Optimizer (33mm Depth)\u003c\/a\u003e\u003cspan\u003eThe current residential power optimiser. One per module is required.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s440-mc4\"\u003eSolar Edge S440 Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe smaller residential optimiser, for modules up to 490 W.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I have to buy optimisers as well?\u003c\/summary\u003e\u003cp\u003eYes. A SolarEdge inverter needs a SolarEdge power optimiser behind every module. Budget for both. The upside is that the optimisers carry a 25-year warranty and do the shade mitigation, string flexibility and per-panel monitoring.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it worth it over a normal string inverter?\u003c\/summary\u003e\u003cp\u003eOn a clean, single-orientation, unshaded roof, often not — a good dual-tracker string inverter costs less and performs similarly. On a shaded, multi-pitch or complex roof, the difference in annual yield is usually decisive.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is SafeDC?\u003c\/summary\u003e\u003cp\u003eWhen the inverter or grid shuts down, each optimiser drops its output to about 1 V, so the array's DC cabling falls to a touch-safe voltage instead of sitting at several hundred volts. It is a genuine safety feature for installers and for the fire service.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard on the inverter, extendable to 25. Optimisers are 25 years as standard.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery?\u003c\/summary\u003e\u003cp\u003eYes — the SolarEdge Home Battery, connected over the SolarEdge Home Network. Note that the specific battery model depends on the inverter; ask us to check your part number before ordering.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs there a display?\u003c\/summary\u003e\u003cp\u003eNo, and deliberately so. Commissioning and monitoring are done through SetApp and the mySolarEdge app, which removes a component that historically failed.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440907362636,"sku":"SE-3000H-NET-5","price":2121.67,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-3000H-NET-5.jpg?v=1778196076"},{"product_id":"se-33300-app-3","title":"SolarEdge 33,300W Three Phase Inverter DC SPD - NO DISPLAY (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Three Phase Commercial SE20K – SE33.3K\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge 33,300W Three Phase Inverter DC SPD - NO DISPLAY (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Three Phase Commercial SE20K – SE33.3K\u003c\/strong\u003e — 20 kW to 33.3 kW, with integrated Type II DC surge protection as standard.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e33,300 W\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e58,275 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.3 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Three Phase Commercial SE20K – SE33.3K\u003c\/h2\u003e\n    \u003cp\u003eThis is SolarEdge's core commercial three-phase range and the one that turns up on most UK industrial roofs in the 20 kW to 33 kW band. It runs at a fixed 680 – 1,000 V operating window with a 1,000 V maximum, which gives long strings and 98.3 % peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eTwo things distinguish it from the ranges below. Type II DC surge protection is integrated and field replaceable as standard, not an option — on an exposed commercial roof with long DC runs, that is the component that quietly earns its keep during a summer storm. And the optional DC Safety Unit provides 1,000 V \/ 48.25 A two-pole disconnection with optional 25 A or 30 A single-pole DC fuses inside the same enclosure.\u003c\/p\u003e\n    \u003cp\u003eRapid shutdown is available as an option, triggering automatically on AC grid disconnect. Combined with SafeDC at the optimiser and integrated arc-fault protection, that gives a DC safety story most commercial insurers are comfortable with.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module.\u003c\/li\u003e\n        \u003cli\u003e1,000 Vdc maximum, 680 – 1,000 Vdc operating window.\u003c\/li\u003e\n        \u003cli\u003eType II DC surge protection integrated and field replaceable as standard; AC Type II optional.\u003c\/li\u003e\n        \u003cli\u003eOptional DC Safety Unit: 1,000 V \/ 48.25 A two-pole disconnection, optional 25 A \/ 30 A DC fuses, UTE-C15-712-1 compliant.\u003c\/li\u003e\n        \u003cli\u003eOptional rapid shutdown (part numbers SExxK-xxRxxxxxx), automatic on AC grid disconnect.\u003c\/li\u003e\n        \u003cli\u003eTwo RS485 ports plus Ethernet; Wi-Fi and cellular optional.\u003c\/li\u003e\n        \u003cli\u003eNote for German sites under VDE-AR-N-4110: the SE33.3K counts as a 30 kW inverter for site capacity, and current limits differ — check the datasheet footnotes.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Three Phase Commercial SE20K – SE33.3K is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eIndustrial and warehouse roofs\u003c\/strong\u003e\u003cspan\u003eThe volume size band for UK commercial rooftop solar.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eAgricultural buildings\u003c\/strong\u003e\u003cspan\u003eLarge barn roofs on three-phase supplies.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-building commercial sites\u003c\/strong\u003e\u003cspan\u003eOne inverter per building, all in one monitoring portal.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRetail parks and distribution\u003c\/strong\u003e\u003cspan\u003eDaytime load matched to generation.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites needing rapid shutdown\u003c\/strong\u003e\u003cspan\u003eWhere the fire officer or the insurer asks for automatic DC de-energisation.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded or plant-cluttered roofs\u003c\/strong\u003e\u003cspan\u003eOptimisers handle the shading commercial roofs always turn out to have.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThe SolarEdge SetApp mobile application is required to commission this inverter. There is no display; commissioning is done from a phone over the inverter's own Wi-Fi access point.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE33.3K technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e58,275 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e48.25 Adc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e33,300 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e33,300 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e48.25 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage — line to line \/ line to neutral (nominal)\u003c\/span\u003e\u003cstrong\u003e380 \/ 220; 400 \/ 230 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e304 – 437 \/ 176 – 253; 320 – 460 \/ 184 – 264.5 Vac\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output line connections\u003c\/span\u003e\u003cstrong\u003e3W + PE, 4W + PE\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor range\u003c\/span\u003e\u003cstrong\u003e±0.2 to 1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum residual current injection\u003c\/span\u003e\u003cstrong\u003e100 mA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage DC+ to DC−\u003c\/span\u003e\u003cstrong\u003e1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating voltage range\u003c\/span\u003e\u003cstrong\u003e680 – 1,000 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e167 kΩ sensitivity\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;4 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003e2 × RS485, Ethernet, Wi-Fi (optional), cellular (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp over the built-in Wi-Fi access point\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRapid shutdown\u003c\/span\u003e\u003cstrong\u003eOptional, automatic on AC grid disconnect\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC surge protection\u003c\/span\u003e\u003cstrong\u003eType II, field replaceable, integrated\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC surge protection\u003c\/span\u003e\u003cstrong\u003eType II, field replaceable, optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC Safety Unit (optional)\u003c\/span\u003e\u003cstrong\u003eTwo-pole disconnection 1,000 V \/ 48.25 A; optional single-pole 25 A \/ 30 A DC fuses; UTE-C15-712-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRoHS\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eVDE-AR-N-4105, VDE-AR-N-4110, AS-4777, EN 50438, CEI-021, VDE 0126-1-1, CEI-016, EN 50549-1, EN 50549-2, TOR Erzeuger Typ A, G99, G99 (NI), VFR 2019\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109, AS 3100\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eSolarEdge Three Phase Commercial Inverter for Europe, DS-000053-EU dated 17 June 2024\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-33300-app\"\u003eSolarEdge 33,300W Three Phase M4 Basic NO DISPLAY\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1000-mc4\"\u003eS1000 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two modules in series, short input lead.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s1200-mc4\"\u003eS1200 Power Optimizer (Short Input 0.1m)\u003c\/a\u003e\u003cspan\u003eCommercial optimiser for two high power or bifacial modules.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs DC surge protection really needed?\u003c\/summary\u003e\u003cp\u003eOn a commercial roof with hundreds of metres of DC cable, yes. Induced surges from nearby lightning are a leading cause of inverter failure on large arrays. Here it is fitted as standard and it is field replaceable, so a hit costs a part rather than an inverter.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does the DC Safety Unit include?\u003c\/summary\u003e\u003cp\u003eTwo-pole DC disconnection rated 1,000 V \/ 48.25 A, with optional single-pole 25 A or 30 A DC fuses, integrated into the inverter enclosure and compliant with UTE-C15-712-1.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need optimisers?\u003c\/summary\u003e\u003cp\u003eYes, on every module.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I export limit?\u003c\/summary\u003e\u003cp\u003eYes, export limitation is part of the smart energy management feature set, and G99 is on the certification list.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is the warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard, extendable to 20.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440907690316,"sku":"SE-33300-APP-3","price":4201.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-33300-APP-3.jpg?v=1778196081"},{"product_id":"se-3500h-net-5","title":"3,500W Home Wave 1PH Inverter (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Home Wave Single Phase\u003c\/div\u003e\n    \u003ch2\u003e3,500W Home Wave 1PH Inverter (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Home Wave Single Phase\u003c\/strong\u003e — HD-Wave, 99 % weighted efficiency, and a panel-by-panel view of your roof.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e3,500 VA\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e7,000 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 25 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x 3,500W Home Wave Inverter - Single Phase (\u003ca href=\"\/products\/SE-3500H-NET\"\u003eSE-3500H-NET\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Home Wave Single Phase\u003c\/h2\u003e\n    \u003cp\u003eA SolarEdge system is a different architecture from a conventional string inverter, and the difference is worth understanding before you choose one. Every panel gets its own power optimiser, which tracks that panel's maximum power point individually and hands the inverter a fixed, well-behaved DC voltage. The inverter then has one job — convert — and it does it at up to 99 % European weighted efficiency, one of the highest figures available anywhere.\u003c\/p\u003e\n    \u003cp\u003eWhat that architecture buys you in practice is threefold. Shading on one panel stops mattering to the rest of the string. String lengths become far more flexible, because the inverter always sees the same voltage. And you get module-level monitoring as standard: the app shows you each panel, so a fault is a specific panel on a specific row rather than a number that looks a bit low.\u003c\/p\u003e\n    \u003cp\u003eThe HD-Wave topology is what makes this range so light and compact for its output — 280 × 370 × 142 mm and IP65, indoors or out, with no external fan. There is a safety dividend as well: SafeDC drops the array's DC voltage to a touch-safe level automatically whenever the inverter or the grid shuts down, and integrated arc-fault protection is built in.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module — this is not a conventional string inverter and will not work without them.\u003c\/li\u003e\n        \u003cli\u003eFixed 380 V nominal DC input, 480 V maximum, so string design is about optimiser count rather than module Voc at temperature.\u003c\/li\u003e\n        \u003cli\u003e200 % DC oversizing supported.\u003c\/li\u003e\n        \u003cli\u003eCommissioned from a phone with SolarEdge SetApp over the inverter's built-in Wi-Fi access point — no display to pay for or fail.\u003c\/li\u003e\n        \u003cli\u003eIntegrated arc-fault protection to UL 1699B, user configurable.\u003c\/li\u003e\n        \u003cli\u003eCertified to G98 and G99, EN 50438, VDE-AR-N-4105 and IEC 61727\/62116.\u003c\/li\u003e\n        \u003cli\u003eConnects to the SolarEdge Home Battery and other Home ecosystem devices over the optional SolarEdge Home Network.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Home Wave Single Phase is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded and complex roofs\u003c\/strong\u003e\u003cspan\u003eThe single strongest reason to choose SolarEdge over a string inverter.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-orientation arrays\u003c\/strong\u003e\u003cspan\u003ePanels on three or four planes on one inverter, all optimised individually.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRoofs with awkward panel counts\u003c\/strong\u003e\u003cspan\u003eFixed-voltage architecture removes most string-length constraints.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCustomers who want per-panel data\u003c\/strong\u003e\u003cspan\u003eModule-level monitoring is standard, not an add-on.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eStorage-ready installs\u003c\/strong\u003e\u003cspan\u003eAdd the SolarEdge Home Battery later over the Home Network.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-term asset owners\u003c\/strong\u003e\u003cspan\u003e12-year warranty as standard, extendable to 25.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis inverter has a battery port. It takes \u003cstrong\u003eReady for the SolarEdge Home Battery over the SolarEdge Home Network\u003c\/strong\u003e.\u003c\/p\u003e    \u003cdiv class=\"cr-warn\"\u003eBattery architecture is not interchangeable. A high-voltage inverter cannot use a 48 V low-voltage battery and vice versa, whatever a compatibility list says, so check the voltage before you order. If you are not certain, ask us and we will confirm it against your part number.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE3500H technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e7,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e10 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e3,500 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e3,500 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e16 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98.8 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC input\u003c\/span\u003e\u003cstrong\u003e1 × MC4 pair\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage (nominal)\u003c\/span\u003e\u003cstrong\u003e220 \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency (nominal)\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e1, adjustable −0.9 to 0.9\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e380 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e600 kΩ sensitivity per unit\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e99.2 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2.5 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp mobile application over built-in Wi-Fi\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485, Ethernet, Wi-Fi (optional), SolarEdge Home Network (optional), cellular (optional), ZigBee (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003cstrong\u003e280 × 370 × 142 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output supported cable diameter\u003c\/span\u003e\u003cstrong\u003e9 – 16 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC supported wire cross section\u003c\/span\u003e\u003cstrong\u003e1 – 13 mm²\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eIEC 61727, IEC 62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE C 15-712, G98, G99, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109-1\/2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 25 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SolarEdge Home Wave 1PH 2.2-6kW EU \/ Home Wave 2.2k-6k NET\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-3500h-net\"\u003e3,500W Home Wave Inverter - Single Phase\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b2-mc4\"\u003eSolar Edge S500B Power Optimizer (33mm Depth)\u003c\/a\u003e\u003cspan\u003eThe current residential power optimiser. One per module is required.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s440-mc4\"\u003eSolar Edge S440 Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe smaller residential optimiser, for modules up to 490 W.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I have to buy optimisers as well?\u003c\/summary\u003e\u003cp\u003eYes. A SolarEdge inverter needs a SolarEdge power optimiser behind every module. Budget for both. The upside is that the optimisers carry a 25-year warranty and do the shade mitigation, string flexibility and per-panel monitoring.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it worth it over a normal string inverter?\u003c\/summary\u003e\u003cp\u003eOn a clean, single-orientation, unshaded roof, often not — a good dual-tracker string inverter costs less and performs similarly. On a shaded, multi-pitch or complex roof, the difference in annual yield is usually decisive.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is SafeDC?\u003c\/summary\u003e\u003cp\u003eWhen the inverter or grid shuts down, each optimiser drops its output to about 1 V, so the array's DC cabling falls to a touch-safe voltage instead of sitting at several hundred volts. It is a genuine safety feature for installers and for the fire service.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard on the inverter, extendable to 25. Optimisers are 25 years as standard.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery?\u003c\/summary\u003e\u003cp\u003eYes — the SolarEdge Home Battery, connected over the SolarEdge Home Network. Note that the specific battery model depends on the inverter; ask us to check your part number before ordering.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs there a display?\u003c\/summary\u003e\u003cp\u003eNo, and deliberately so. Commissioning and monitoring are done through SetApp and the mySolarEdge app, which removes a component that historically failed.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440907755852,"sku":"SE-3500H-NET-5","price":2932.25,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-3500H-NET-5.jpg?v=1778196083"},{"product_id":"se-3680h-net-5","title":"3,680W Home Wave Inverter - Single Phase (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Home Wave Single Phase\u003c\/div\u003e\n    \u003ch2\u003e3,680W Home Wave Inverter - Single Phase (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Home Wave Single Phase\u003c\/strong\u003e — HD-Wave, 99 % weighted efficiency, and a panel-by-panel view of your roof.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e3,680 VA\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e7,360 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 25 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x 3,680W Home Wave Inverter - Single Phase (\u003ca href=\"\/products\/SE-3680H-NET\"\u003eSE-3680H-NET\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Home Wave Single Phase\u003c\/h2\u003e\n    \u003cp\u003eA SolarEdge system is a different architecture from a conventional string inverter, and the difference is worth understanding before you choose one. Every panel gets its own power optimiser, which tracks that panel's maximum power point individually and hands the inverter a fixed, well-behaved DC voltage. The inverter then has one job — convert — and it does it at up to 99 % European weighted efficiency, one of the highest figures available anywhere.\u003c\/p\u003e\n    \u003cp\u003eWhat that architecture buys you in practice is threefold. Shading on one panel stops mattering to the rest of the string. String lengths become far more flexible, because the inverter always sees the same voltage. And you get module-level monitoring as standard: the app shows you each panel, so a fault is a specific panel on a specific row rather than a number that looks a bit low.\u003c\/p\u003e\n    \u003cp\u003eThe HD-Wave topology is what makes this range so light and compact for its output — 280 × 370 × 142 mm and IP65, indoors or out, with no external fan. There is a safety dividend as well: SafeDC drops the array's DC voltage to a touch-safe level automatically whenever the inverter or the grid shuts down, and integrated arc-fault protection is built in.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module — this is not a conventional string inverter and will not work without them.\u003c\/li\u003e\n        \u003cli\u003eFixed 380 V nominal DC input, 480 V maximum, so string design is about optimiser count rather than module Voc at temperature.\u003c\/li\u003e\n        \u003cli\u003e200 % DC oversizing supported.\u003c\/li\u003e\n        \u003cli\u003eCommissioned from a phone with SolarEdge SetApp over the inverter's built-in Wi-Fi access point — no display to pay for or fail.\u003c\/li\u003e\n        \u003cli\u003eIntegrated arc-fault protection to UL 1699B, user configurable.\u003c\/li\u003e\n        \u003cli\u003eCertified to G98 and G99, EN 50438, VDE-AR-N-4105 and IEC 61727\/62116.\u003c\/li\u003e\n        \u003cli\u003eConnects to the SolarEdge Home Battery and other Home ecosystem devices over the optional SolarEdge Home Network.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Home Wave Single Phase is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded and complex roofs\u003c\/strong\u003e\u003cspan\u003eThe single strongest reason to choose SolarEdge over a string inverter.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-orientation arrays\u003c\/strong\u003e\u003cspan\u003ePanels on three or four planes on one inverter, all optimised individually.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRoofs with awkward panel counts\u003c\/strong\u003e\u003cspan\u003eFixed-voltage architecture removes most string-length constraints.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCustomers who want per-panel data\u003c\/strong\u003e\u003cspan\u003eModule-level monitoring is standard, not an add-on.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eStorage-ready installs\u003c\/strong\u003e\u003cspan\u003eAdd the SolarEdge Home Battery later over the Home Network.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-term asset owners\u003c\/strong\u003e\u003cspan\u003e12-year warranty as standard, extendable to 25.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis inverter has a battery port. It takes \u003cstrong\u003eReady for the SolarEdge Home Battery over the SolarEdge Home Network\u003c\/strong\u003e.\u003c\/p\u003e    \u003cdiv class=\"cr-warn\"\u003eBattery architecture is not interchangeable. A high-voltage inverter cannot use a 48 V low-voltage battery and vice versa, whatever a compatibility list says, so check the voltage before you order. If you are not certain, ask us and we will confirm it against your part number.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE3680H technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e7,360 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e10.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e3,680 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e3,680 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e16 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e98.8 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC input\u003c\/span\u003e\u003cstrong\u003e1 × MC4 pair\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage (nominal)\u003c\/span\u003e\u003cstrong\u003e220 \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency (nominal)\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e1, adjustable −0.9 to 0.9\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e380 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e600 kΩ sensitivity per unit\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e99.2 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2.5 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp mobile application over built-in Wi-Fi\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485, Ethernet, Wi-Fi (optional), SolarEdge Home Network (optional), cellular (optional), ZigBee (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003cstrong\u003e280 × 370 × 142 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output supported cable diameter\u003c\/span\u003e\u003cstrong\u003e9 – 16 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC supported wire cross section\u003c\/span\u003e\u003cstrong\u003e1 – 13 mm²\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eIEC 61727, IEC 62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE C 15-712, G98, G99, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109-1\/2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 25 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SolarEdge Home Wave 1PH 2.2-6kW EU \/ Home Wave 2.2k-6k NET\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b2-mc4\"\u003eSolar Edge S500B Power Optimizer (33mm Depth)\u003c\/a\u003e\u003cspan\u003eThe current residential power optimiser. One per module is required.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s440-mc4\"\u003eSolar Edge S440 Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe smaller residential optimiser, for modules up to 490 W.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s650-b-mc4\"\u003eSolarEdge S650B Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe 650 W residential optimiser, for large-format modules.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I have to buy optimisers as well?\u003c\/summary\u003e\u003cp\u003eYes. A SolarEdge inverter needs a SolarEdge power optimiser behind every module. Budget for both. The upside is that the optimisers carry a 25-year warranty and do the shade mitigation, string flexibility and per-panel monitoring.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it worth it over a normal string inverter?\u003c\/summary\u003e\u003cp\u003eOn a clean, single-orientation, unshaded roof, often not — a good dual-tracker string inverter costs less and performs similarly. On a shaded, multi-pitch or complex roof, the difference in annual yield is usually decisive.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is SafeDC?\u003c\/summary\u003e\u003cp\u003eWhen the inverter or grid shuts down, each optimiser drops its output to about 1 V, so the array's DC cabling falls to a touch-safe voltage instead of sitting at several hundred volts. It is a genuine safety feature for installers and for the fire service.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard on the inverter, extendable to 25. Optimisers are 25 years as standard.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery?\u003c\/summary\u003e\u003cp\u003eYes — the SolarEdge Home Battery, connected over the SolarEdge Home Network. Note that the specific battery model depends on the inverter; ask us to check your part number before ordering.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs there a display?\u003c\/summary\u003e\u003cp\u003eNo, and deliberately so. Commissioning and monitoring are done through SetApp and the mySolarEdge app, which removes a component that historically failed.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440907919692,"sku":"SE-3680H-NET-5","price":2474.8,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-3680H-NET-5.jpg?v=1778196086"},{"product_id":"se-5000h-net-4","title":"5,000W Home Wave Inverter - Single Phase (Pack of 4)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Home Wave Single Phase\u003c\/div\u003e\n    \u003ch2\u003e5,000W Home Wave Inverter - Single Phase (Pack of 4)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Home Wave Single Phase\u003c\/strong\u003e — HD-Wave, 99 % weighted efficiency, and a panel-by-panel view of your roof.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 4\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e5,000 VA\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e10,000 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 25 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 4 x 5,000W Home Wave Inverter - Single Phase (\u003ca href=\"\/products\/SE-5000H-NET\"\u003eSE-5000H-NET\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Home Wave Single Phase\u003c\/h2\u003e\n    \u003cp\u003eA SolarEdge system is a different architecture from a conventional string inverter, and the difference is worth understanding before you choose one. Every panel gets its own power optimiser, which tracks that panel's maximum power point individually and hands the inverter a fixed, well-behaved DC voltage. The inverter then has one job — convert — and it does it at up to 99 % European weighted efficiency, one of the highest figures available anywhere.\u003c\/p\u003e\n    \u003cp\u003eWhat that architecture buys you in practice is threefold. Shading on one panel stops mattering to the rest of the string. String lengths become far more flexible, because the inverter always sees the same voltage. And you get module-level monitoring as standard: the app shows you each panel, so a fault is a specific panel on a specific row rather than a number that looks a bit low.\u003c\/p\u003e\n    \u003cp\u003eThe HD-Wave topology is what makes this range so light and compact for its output — 280 × 370 × 142 mm and IP65, indoors or out, with no external fan. There is a safety dividend as well: SafeDC drops the array's DC voltage to a touch-safe level automatically whenever the inverter or the grid shuts down, and integrated arc-fault protection is built in.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module — this is not a conventional string inverter and will not work without them.\u003c\/li\u003e\n        \u003cli\u003eFixed 380 V nominal DC input, 480 V maximum, so string design is about optimiser count rather than module Voc at temperature.\u003c\/li\u003e\n        \u003cli\u003e200 % DC oversizing supported.\u003c\/li\u003e\n        \u003cli\u003eCommissioned from a phone with SolarEdge SetApp over the inverter's built-in Wi-Fi access point — no display to pay for or fail.\u003c\/li\u003e\n        \u003cli\u003eIntegrated arc-fault protection to UL 1699B, user configurable.\u003c\/li\u003e\n        \u003cli\u003eCertified to G98 and G99, EN 50438, VDE-AR-N-4105 and IEC 61727\/62116.\u003c\/li\u003e\n        \u003cli\u003eConnects to the SolarEdge Home Battery and other Home ecosystem devices over the optional SolarEdge Home Network.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Home Wave Single Phase is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded and complex roofs\u003c\/strong\u003e\u003cspan\u003eThe single strongest reason to choose SolarEdge over a string inverter.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-orientation arrays\u003c\/strong\u003e\u003cspan\u003ePanels on three or four planes on one inverter, all optimised individually.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRoofs with awkward panel counts\u003c\/strong\u003e\u003cspan\u003eFixed-voltage architecture removes most string-length constraints.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCustomers who want per-panel data\u003c\/strong\u003e\u003cspan\u003eModule-level monitoring is standard, not an add-on.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eStorage-ready installs\u003c\/strong\u003e\u003cspan\u003eAdd the SolarEdge Home Battery later over the Home Network.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-term asset owners\u003c\/strong\u003e\u003cspan\u003e12-year warranty as standard, extendable to 25.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis inverter has a battery port. It takes \u003cstrong\u003eReady for the SolarEdge Home Battery over the SolarEdge Home Network\u003c\/strong\u003e.\u003c\/p\u003e    \u003cdiv class=\"cr-warn\"\u003eBattery architecture is not interchangeable. A high-voltage inverter cannot use a 48 V low-voltage battery and vice versa, whatever a compatibility list says, so check the voltage before you order. If you are not certain, ask us and we will confirm it against your part number.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThis inverter does not have a display. Commissioning is carried out through the SolarEdge SetApp.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE5000H technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e10,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e13.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e5,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e5,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e23 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e99 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC input\u003c\/span\u003e\u003cstrong\u003e2 × MC4 pair\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage (nominal)\u003c\/span\u003e\u003cstrong\u003e220 \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency (nominal)\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e1, adjustable −0.9 to 0.9\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e380 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e600 kΩ sensitivity per unit\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e99.2 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2.5 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp mobile application over built-in Wi-Fi\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485, Ethernet, Wi-Fi (optional), SolarEdge Home Network (optional), cellular (optional), ZigBee (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003cstrong\u003e280 × 370 × 142 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output supported cable diameter\u003c\/span\u003e\u003cstrong\u003e9 – 16 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC supported wire cross section\u003c\/span\u003e\u003cstrong\u003e1 – 13 mm²\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eIEC 61727, IEC 62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE C 15-712, G98, G99, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109-1\/2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 25 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SolarEdge Home Wave 1PH 2.2-6kW EU \/ Home Wave 2.2k-6k NET\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-5000h-net\"\u003e5,000W Home Wave Inverter - Single Phase\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b2-mc4\"\u003eSolar Edge S500B Power Optimizer (33mm Depth)\u003c\/a\u003e\u003cspan\u003eThe current residential power optimiser. One per module is required.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s440-mc4\"\u003eSolar Edge S440 Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe smaller residential optimiser, for modules up to 490 W.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I have to buy optimisers as well?\u003c\/summary\u003e\u003cp\u003eYes. A SolarEdge inverter needs a SolarEdge power optimiser behind every module. Budget for both. The upside is that the optimisers carry a 25-year warranty and do the shade mitigation, string flexibility and per-panel monitoring.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it worth it over a normal string inverter?\u003c\/summary\u003e\u003cp\u003eOn a clean, single-orientation, unshaded roof, often not — a good dual-tracker string inverter costs less and performs similarly. On a shaded, multi-pitch or complex roof, the difference in annual yield is usually decisive.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is SafeDC?\u003c\/summary\u003e\u003cp\u003eWhen the inverter or grid shuts down, each optimiser drops its output to about 1 V, so the array's DC cabling falls to a touch-safe voltage instead of sitting at several hundred volts. It is a genuine safety feature for installers and for the fire service.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard on the inverter, extendable to 25. Optimisers are 25 years as standard.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery?\u003c\/summary\u003e\u003cp\u003eYes — the SolarEdge Home Battery, connected over the SolarEdge Home Network. Note that the specific battery model depends on the inverter; ask us to check your part number before ordering.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs there a display?\u003c\/summary\u003e\u003cp\u003eNo, and deliberately so. Commissioning and monitoring are done through SetApp and the mySolarEdge app, which removes a component that historically failed.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440908542284,"sku":"SE-5000H-NET-4","price":2203.01,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-5000H-NET-4.jpg?v=1778196092"},{"product_id":"se-6000h-app-4","title":"SolarEdge 6000W Single Phase HD Wave Inverter NO DISPLAY (Pack of 4)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Home Wave Single Phase\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge 6000W Single Phase HD Wave Inverter NO DISPLAY (Pack of 4)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Home Wave Single Phase\u003c\/strong\u003e — HD-Wave, 99 % weighted efficiency, and a panel-by-panel view of your roof.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 4\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e6,000 VA\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e12,000 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 25 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 4 x SolarEdge 6000W Single Phase Home Wave Inverter NO DISPLAY (\u003ca href=\"\/products\/SE-6000H-APP\"\u003eSE-6000H-APP\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Home Wave Single Phase\u003c\/h2\u003e\n    \u003cp\u003eA SolarEdge system is a different architecture from a conventional string inverter, and the difference is worth understanding before you choose one. Every panel gets its own power optimiser, which tracks that panel's maximum power point individually and hands the inverter a fixed, well-behaved DC voltage. The inverter then has one job — convert — and it does it at up to 99 % European weighted efficiency, one of the highest figures available anywhere.\u003c\/p\u003e\n    \u003cp\u003eWhat that architecture buys you in practice is threefold. Shading on one panel stops mattering to the rest of the string. String lengths become far more flexible, because the inverter always sees the same voltage. And you get module-level monitoring as standard: the app shows you each panel, so a fault is a specific panel on a specific row rather than a number that looks a bit low.\u003c\/p\u003e\n    \u003cp\u003eThe HD-Wave topology is what makes this range so light and compact for its output — 280 × 370 × 142 mm and IP65, indoors or out, with no external fan. There is a safety dividend as well: SafeDC drops the array's DC voltage to a touch-safe level automatically whenever the inverter or the grid shuts down, and integrated arc-fault protection is built in.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module — this is not a conventional string inverter and will not work without them.\u003c\/li\u003e\n        \u003cli\u003eFixed 380 V nominal DC input, 480 V maximum, so string design is about optimiser count rather than module Voc at temperature.\u003c\/li\u003e\n        \u003cli\u003e200 % DC oversizing supported.\u003c\/li\u003e\n        \u003cli\u003eCommissioned from a phone with SolarEdge SetApp over the inverter's built-in Wi-Fi access point — no display to pay for or fail.\u003c\/li\u003e\n        \u003cli\u003eIntegrated arc-fault protection to UL 1699B, user configurable.\u003c\/li\u003e\n        \u003cli\u003eCertified to G98 and G99, EN 50438, VDE-AR-N-4105 and IEC 61727\/62116.\u003c\/li\u003e\n        \u003cli\u003eConnects to the SolarEdge Home Battery and other Home ecosystem devices over the optional SolarEdge Home Network.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Home Wave Single Phase is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded and complex roofs\u003c\/strong\u003e\u003cspan\u003eThe single strongest reason to choose SolarEdge over a string inverter.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-orientation arrays\u003c\/strong\u003e\u003cspan\u003ePanels on three or four planes on one inverter, all optimised individually.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRoofs with awkward panel counts\u003c\/strong\u003e\u003cspan\u003eFixed-voltage architecture removes most string-length constraints.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCustomers who want per-panel data\u003c\/strong\u003e\u003cspan\u003eModule-level monitoring is standard, not an add-on.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eStorage-ready installs\u003c\/strong\u003e\u003cspan\u003eAdd the SolarEdge Home Battery later over the Home Network.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-term asset owners\u003c\/strong\u003e\u003cspan\u003e12-year warranty as standard, extendable to 25.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis inverter has a battery port. It takes \u003cstrong\u003eReady for the SolarEdge Home Battery over the SolarEdge Home Network\u003c\/strong\u003e.\u003c\/p\u003e    \u003cdiv class=\"cr-warn\"\u003eBattery architecture is not interchangeable. A high-voltage inverter cannot use a 48 V low-voltage battery and vice versa, whatever a compatibility list says, so check the voltage before you order. If you are not certain, ask us and we will confirm it against your part number.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThe SolarEdge SetApp mobile application is required to commission this inverter. There is no display; commissioning is done from a phone over the inverter's own Wi-Fi access point.\u003c\/li\u003e\n        \u003cli\u003eUK only: this inverter is tested and certified to G98 or G99 only with the most recent firmware version. Update the inverter firmware during the SetApp commissioning process, as set out in the installation manual.\u003c\/li\u003e\n        \u003cli\u003eThis inverter does not have a display. It is the new Comms Board version, and set-up and commissioning are done with the SolarEdge SetApp mobile application.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE6000H technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e12,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e16.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e6,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e6,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e27.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e99 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC input\u003c\/span\u003e\u003cstrong\u003e2 × MC4 pair\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage (nominal)\u003c\/span\u003e\u003cstrong\u003e220 \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency (nominal)\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e1, adjustable −0.9 to 0.9\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e380 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e600 kΩ sensitivity per unit\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e99.2 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2.5 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp mobile application over built-in Wi-Fi\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485, Ethernet, Wi-Fi (optional), SolarEdge Home Network (optional), cellular (optional), ZigBee (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003cstrong\u003e280 × 370 × 142 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output supported cable diameter\u003c\/span\u003e\u003cstrong\u003e9 – 16 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC supported wire cross section\u003c\/span\u003e\u003cstrong\u003e1 – 13 mm²\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eIEC 61727, IEC 62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE C 15-712, G98, G99, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109-1\/2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 25 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SolarEdge Home Wave 1PH 2.2-6kW EU \/ Home Wave 2.2k-6k NET\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-6000h-app\"\u003eSolarEdge 6000W Single Phase Home Wave Inverter NO DISPLAY\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b2-mc4\"\u003eSolar Edge S500B Power Optimizer (33mm Depth)\u003c\/a\u003e\u003cspan\u003eThe current residential power optimiser. One per module is required.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s440-mc4\"\u003eSolar Edge S440 Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe smaller residential optimiser, for modules up to 490 W.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I have to buy optimisers as well?\u003c\/summary\u003e\u003cp\u003eYes. A SolarEdge inverter needs a SolarEdge power optimiser behind every module. Budget for both. The upside is that the optimisers carry a 25-year warranty and do the shade mitigation, string flexibility and per-panel monitoring.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it worth it over a normal string inverter?\u003c\/summary\u003e\u003cp\u003eOn a clean, single-orientation, unshaded roof, often not — a good dual-tracker string inverter costs less and performs similarly. On a shaded, multi-pitch or complex roof, the difference in annual yield is usually decisive.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is SafeDC?\u003c\/summary\u003e\u003cp\u003eWhen the inverter or grid shuts down, each optimiser drops its output to about 1 V, so the array's DC cabling falls to a touch-safe voltage instead of sitting at several hundred volts. It is a genuine safety feature for installers and for the fire service.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard on the inverter, extendable to 25. Optimisers are 25 years as standard.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery?\u003c\/summary\u003e\u003cp\u003eYes — the SolarEdge Home Battery, connected over the SolarEdge Home Network. Note that the specific battery model depends on the inverter; ask us to check your part number before ordering.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs there a display?\u003c\/summary\u003e\u003cp\u003eNo, and deliberately so. Commissioning and monitoring are done through SetApp and the mySolarEdge app, which removes a component that historically failed.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440908902732,"sku":"SE-6000H-APP-4","price":5071.14,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-6000H-APP-4.jpg?v=1778196096"},{"product_id":"se-6000h-net-4","title":"6,000W Home Wave Inverter - Single Phase (Pack of 4)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Home Wave Single Phase\u003c\/div\u003e\n    \u003ch2\u003e6,000W Home Wave Inverter - Single Phase (Pack of 4)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Home Wave Single Phase\u003c\/strong\u003e — HD-Wave, 99 % weighted efficiency, and a panel-by-panel view of your roof.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 4\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e6,000 VA\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e12,000 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 25 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 4 x 6,000W Home Wave Inverter - Single Phase (\u003ca href=\"\/products\/SE-6000H-NET\"\u003eSE-6000H-NET\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Home Wave Single Phase\u003c\/h2\u003e\n    \u003cp\u003eA SolarEdge system is a different architecture from a conventional string inverter, and the difference is worth understanding before you choose one. Every panel gets its own power optimiser, which tracks that panel's maximum power point individually and hands the inverter a fixed, well-behaved DC voltage. The inverter then has one job — convert — and it does it at up to 99 % European weighted efficiency, one of the highest figures available anywhere.\u003c\/p\u003e\n    \u003cp\u003eWhat that architecture buys you in practice is threefold. Shading on one panel stops mattering to the rest of the string. String lengths become far more flexible, because the inverter always sees the same voltage. And you get module-level monitoring as standard: the app shows you each panel, so a fault is a specific panel on a specific row rather than a number that looks a bit low.\u003c\/p\u003e\n    \u003cp\u003eThe HD-Wave topology is what makes this range so light and compact for its output — 280 × 370 × 142 mm and IP65, indoors or out, with no external fan. There is a safety dividend as well: SafeDC drops the array's DC voltage to a touch-safe level automatically whenever the inverter or the grid shuts down, and integrated arc-fault protection is built in.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module — this is not a conventional string inverter and will not work without them.\u003c\/li\u003e\n        \u003cli\u003eFixed 380 V nominal DC input, 480 V maximum, so string design is about optimiser count rather than module Voc at temperature.\u003c\/li\u003e\n        \u003cli\u003e200 % DC oversizing supported.\u003c\/li\u003e\n        \u003cli\u003eCommissioned from a phone with SolarEdge SetApp over the inverter's built-in Wi-Fi access point — no display to pay for or fail.\u003c\/li\u003e\n        \u003cli\u003eIntegrated arc-fault protection to UL 1699B, user configurable.\u003c\/li\u003e\n        \u003cli\u003eCertified to G98 and G99, EN 50438, VDE-AR-N-4105 and IEC 61727\/62116.\u003c\/li\u003e\n        \u003cli\u003eConnects to the SolarEdge Home Battery and other Home ecosystem devices over the optional SolarEdge Home Network.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Home Wave Single Phase is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded and complex roofs\u003c\/strong\u003e\u003cspan\u003eThe single strongest reason to choose SolarEdge over a string inverter.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMulti-orientation arrays\u003c\/strong\u003e\u003cspan\u003ePanels on three or four planes on one inverter, all optimised individually.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRoofs with awkward panel counts\u003c\/strong\u003e\u003cspan\u003eFixed-voltage architecture removes most string-length constraints.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCustomers who want per-panel data\u003c\/strong\u003e\u003cspan\u003eModule-level monitoring is standard, not an add-on.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eStorage-ready installs\u003c\/strong\u003e\u003cspan\u003eAdd the SolarEdge Home Battery later over the Home Network.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLong-term asset owners\u003c\/strong\u003e\u003cspan\u003e12-year warranty as standard, extendable to 25.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis inverter has a battery port. It takes \u003cstrong\u003eReady for the SolarEdge Home Battery over the SolarEdge Home Network\u003c\/strong\u003e.\u003c\/p\u003e    \u003cdiv class=\"cr-warn\"\u003eBattery architecture is not interchangeable. A high-voltage inverter cannot use a 48 V low-voltage battery and vice versa, whatever a compatibility list says, so check the voltage before you order. If you are not certain, ask us and we will confirm it against your part number.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE6000H technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e12,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e16.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e6,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e6,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e27.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e99 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC input\u003c\/span\u003e\u003cstrong\u003e2 × MC4 pair\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage (nominal)\u003c\/span\u003e\u003cstrong\u003e220 \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency (nominal)\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e1, adjustable −0.9 to 0.9\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e380 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eReverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e600 kΩ sensitivity per unit\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e99.2 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2.5 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp mobile application over built-in Wi-Fi\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485, Ethernet, Wi-Fi (optional), SolarEdge Home Network (optional), cellular (optional), ZigBee (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003cstrong\u003e280 × 370 × 142 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output supported cable diameter\u003c\/span\u003e\u003cstrong\u003e9 – 16 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC supported wire cross section\u003c\/span\u003e\u003cstrong\u003e1 – 13 mm²\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eIEC 61727, IEC 62116, EN 50438, VDE-AR-N-4105, VDE 0126-1-1, UTE C 15-712, G98, G99, CEI-021, ÖNORM, TF3.2.1, C10-11, NRS 097-2-1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109-1\/2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 25 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SolarEdge Home Wave 1PH 2.2-6kW EU \/ Home Wave 2.2k-6k NET\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-6000h-net\"\u003e6,000W Home Wave Inverter - Single Phase\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b2-mc4\"\u003eSolar Edge S500B Power Optimizer (33mm Depth)\u003c\/a\u003e\u003cspan\u003eThe current residential power optimiser. One per module is required.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s440-mc4\"\u003eSolar Edge S440 Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe smaller residential optimiser, for modules up to 490 W.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I have to buy optimisers as well?\u003c\/summary\u003e\u003cp\u003eYes. A SolarEdge inverter needs a SolarEdge power optimiser behind every module. Budget for both. The upside is that the optimisers carry a 25-year warranty and do the shade mitigation, string flexibility and per-panel monitoring.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it worth it over a normal string inverter?\u003c\/summary\u003e\u003cp\u003eOn a clean, single-orientation, unshaded roof, often not — a good dual-tracker string inverter costs less and performs similarly. On a shaded, multi-pitch or complex roof, the difference in annual yield is usually decisive.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is SafeDC?\u003c\/summary\u003e\u003cp\u003eWhen the inverter or grid shuts down, each optimiser drops its output to about 1 V, so the array's DC cabling falls to a touch-safe voltage instead of sitting at several hundred volts. It is a genuine safety feature for installers and for the fire service.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty?\u003c\/summary\u003e\u003cp\u003e12 years standard on the inverter, extendable to 25. Optimisers are 25 years as standard.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery?\u003c\/summary\u003e\u003cp\u003eYes — the SolarEdge Home Battery, connected over the SolarEdge Home Network. Note that the specific battery model depends on the inverter; ask us to check your part number before ordering.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs there a display?\u003c\/summary\u003e\u003cp\u003eNo, and deliberately so. Commissioning and monitoring are done through SetApp and the mySolarEdge app, which removes a component that historically failed.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440908968268,"sku":"SE-6000H-NET-4","price":2636.54,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-6000H-NET-4.jpg?v=1778196098"},{"product_id":"se-8000h-net-3","title":"8,000W Home Wave Inverter - Single Phase (Pack of 3)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolarEdge · Home Wave Single Phase, 8 – 10 kW\u003c\/div\u003e\n    \u003ch2\u003e8,000W Home Wave Inverter - Single Phase (Pack of 3)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolarEdge Home Wave Single Phase, 8 – 10 kW\u003c\/strong\u003e — The single-phase ceiling: 10 kW AC, 20 kW DC, 99 % weighted.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 3\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e8,000 VA\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e16,000 W\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e12 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 25 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 3 x 8,000W Home Wave Inverter - Single Phase (\u003ca href=\"\/products\/SE-8000H-NET\"\u003eSE-8000H-NET\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the SolarEdge Home Wave Single Phase, 8 – 10 kW\u003c\/h2\u003e\n    \u003cp\u003eThis is the top of SolarEdge's single-phase Home Wave range for the UK, and it exists for houses whose electrical demand has outgrown a conventional domestic array — a heat pump, two EVs, a home office, or simply a very large roof.\u003c\/p\u003e\n    \u003cp\u003eThe specification that stands out is DC oversizing: 20,000 W of modules on a 10,000 W inverter. Because SolarEdge optimisers present a fixed voltage, that 200 % ratio is a supported design rather than an overload, and in UK light conditions the array spends almost all of its year below the clipping threshold anyway. You harvest far more in spring and autumn and lose a handful of hours at midsummer.\u003c\/p\u003e\n    \u003cp\u003eEuropean weighted efficiency is 99 %, which is about as good as grid-tied conversion gets, and it comes with the same module-level monitoring, SafeDC shutdown and integrated arc-fault protection as the rest of the range.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eRequires SolarEdge power optimisers on every module.\u003c\/li\u003e\n        \u003cli\u003eThree MC4 pairs on the DC side. Nominal DC input 400 V, maximum 480 V.\u003c\/li\u003e\n        \u003cli\u003e45.5 A continuous output at 10 kW — check the consumer unit, the tails and the DNO position before you commit.\u003c\/li\u003e\n        \u003cli\u003eThis will be a G99 application on a single-phase supply, not a G98 notification.\u003c\/li\u003e\n        \u003cli\u003eCertified to G83\/1, G83\/2 and G59\/3 on the datasheet; check current G98\/G99 documentation for your application.\u003c\/li\u003e\n        \u003cli\u003e360 × 370 × 185 mm, 16.5 kg, IP65, natural convection, under 50 dBA.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe Home Wave Single Phase, 8 – 10 kW is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eVery large domestic roofs\u003c\/strong\u003e\u003cspan\u003eWhere the array is 12 kWp or more and the supply is single phase.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eHeat pump plus EV households\u003c\/strong\u003e\u003cspan\u003eSized for a home that has electrified its heating and its driving.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eBarn conversions and large rural houses\u003c\/strong\u003e\u003cspan\u003eBig roof, single-phase supply.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eHeavily oversized DC arrays\u003c\/strong\u003e\u003cspan\u003e200 % DC\/AC is designed in, which suits UK irradiance.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eShaded large roofs\u003c\/strong\u003e\u003cspan\u003eOptimiser architecture handles complex shading a string inverter cannot.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis inverter has a battery port. It takes \u003cstrong\u003eCompatible with SolarEdge Energy Bank, subject to inverter firmware support\u003c\/strong\u003e.\u003c\/p\u003e    \u003cdiv class=\"cr-warn\"\u003eBattery architecture is not interchangeable. A high-voltage inverter cannot use a 48 V low-voltage battery and vice versa, whatever a compatibility list says, so check the voltage before you order. If you are not certain, ask us and we will confirm it against your part number.\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolarEdge SE8000H technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e16,000 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e20.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e8,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e8,000 VA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e36.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage (nominal)\u003c\/span\u003e\u003cstrong\u003e220 \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC output voltage range\u003c\/span\u003e\u003cstrong\u003e184 – 264.5 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC frequency (nominal)\u003c\/span\u003e\u003cstrong\u003e50 \/ 60 ±5 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTotal harmonic distortion\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e1, adjustable −0.8 to 0.8\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTransformer-less, ungrounded\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e480 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNominal DC input voltage\u003c\/span\u003e\u003cstrong\u003e400 Vdc\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum inverter efficiency\u003c\/span\u003e\u003cstrong\u003e99.2 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e99 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNighttime power consumption\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2.5 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGround fault isolation detection\u003c\/span\u003e\u003cstrong\u003e600 kΩ sensitivity per unit\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eArc fault protection\u003c\/span\u003e\u003cstrong\u003eIntegrated, user configurable, to UL 1699B\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eInverter commissioning\u003c\/span\u003e\u003cstrong\u003eSetApp mobile application over built-in Wi-Fi access point\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485, Ethernet, ZigBee (optional), SolarEdge Home Network (optional), Wi-Fi (optional), cellular (optional)\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSmart energy management\u003c\/span\u003e\u003cstrong\u003eExport limitation\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC input\u003c\/span\u003e\u003cstrong\u003e3 × MC4 pair\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (H × W × D)\u003c\/span\u003e\u003cstrong\u003e360 × 370 × 185 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e16.5 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNoise\u003c\/span\u003e\u003cstrong\u003e\u0026lt;50 dBA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating temperature range\u003c\/span\u003e\u003cstrong\u003e−40 °C to +60 °C, full power to at least +50 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP65, outdoor and indoor\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG83\/1, G83\/2, G59\/3, RD 661, RD 1699, UTE C15-712\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC 62109\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e12 years standard, extendable to 25 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SolarEdge Home Wave 8k-10k Net (DS-000119-ENG)\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/se-8000h-net\"\u003e8,000W Home Wave Inverter - Single Phase\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s500-b2-mc4\"\u003eSolar Edge S500B Power Optimizer (33mm Depth)\u003c\/a\u003e\u003cspan\u003eThe current residential power optimiser. One per module is required.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/s650-b-mc4\"\u003eSolarEdge S650B Power Optimizer\u003c\/a\u003e\u003cspan\u003eThe 650 W residential optimiser, for large-format modules.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I really put 20 kW of panels on a 10 kW inverter?\u003c\/summary\u003e\u003cp\u003eYes, that is the datasheet figure. In UK conditions an array rarely reaches its STC rating, so the clipping loss is small and the gains on dull days are large. Model it before committing, but do not be put off by the ratio.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWill the DNO allow 10 kW on single phase?\u003c\/summary\u003e\u003cp\u003eIt is a G99 application and the answer is network-specific. Many will approve it with an export limit. Apply early.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I need optimisers?\u003c\/summary\u003e\u003cp\u003eYes, on every module. This is not a conventional string inverter.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eBattery?\u003c\/summary\u003e\u003cp\u003eThe datasheet lists the SolarEdge Energy Bank, subject to inverter firmware support. If storage is the goal from day one, the Home Hub inverter is the purpose-built choice — ask us and we will check your part number.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"SolarEdge","offers":[{"title":"Default Title","offer_id":57440909492556,"sku":"SE-8000H-NET-3","price":2515.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SE-8000H-NET-3.jpg?v=1778196104"},{"product_id":"sol-0-7-mini-s6-dc-5","title":"Solis 0.7kW Mini S6 Single Tracker with DC isolator (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · S6 Mini\u003c\/div\u003e\n    \u003ch2\u003eSolis 0.7kW Mini S6 Single Tracker with DC isolator (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis S6 Mini\u003c\/strong\u003e — The small single-tracker inverter that makes a modest roof worth doing.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e0.7 kW\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e1.1 kW\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e96.6 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e600 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x S6 0.7kW Mini Single Tracker with DC isolator (\u003ca href=\"\/products\/SOL-0.7-MINI-S6-DC\"\u003eSOL-0.7-MINI-S6-DC\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-0.7-MINI-S6-DC-10\"\u003eSolis 0.7kW Mini S6 Single Tracker with DC isolator (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-0.7-MINI-S6-DC-24\"\u003eSolis 0.7kW Mini S6 Single Tracker with DC isolator (1x Pallet)\u003c\/a\u003e \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis S6 Mini\u003c\/h2\u003e\n    \u003cp\u003eMost UK roofs that get turned down for solar are turned down for the same reason: one usable pitch, room for six or eight panels, and a quote built around an inverter designed for twice that array. The Solis S6 Mini exists for exactly those roofs. It is a single-MPPT, single-phase string inverter in seven power steps from 0.7 kW to 3.6 kW, so the inverter can be sized to the array rather than the array sized to the inverter.\u003c\/p\u003e\n    \u003cp\u003eThe engineering that matters here is at the bottom of the power curve, not the top. A 60 V start-up voltage on the smaller models and an MPPT window that opens at 50 V means the inverter is awake and exporting on a dull February morning, when a higher-threshold unit is still sitting at zero. Over a UK year that low-light behaviour is worth more than a tenth of a percent on peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eIt is also genuinely small — 310 × 373 × 160 mm and 7.4 kg — which matters more than the spec sheet suggests. It goes on a garage wall, in a loft, or in a cupboard without a second pair of hands, and it is rated IP66 so it can equally live outside.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eIntegrated AFCI (activation required) and an optional integrated DC switch — the SKUs we stock are the DC-isolator versions, so there is no separate isolator to buy, mount and wire.\u003c\/li\u003e\n        \u003cli\u003eG98 and G99 certified, with EN 50549-1 and VDE-AR-N 4105 on the same sheet, so the DNO paperwork is straightforward on either route.\u003c\/li\u003e\n        \u003cli\u003eIntegrated Export Power Manager, so an export limit can be set without an external EPM box.\u003c\/li\u003e\n        \u003cli\u003eRS485 as standard with Wi-Fi and GPRS dataloggers optional, all reporting into SolisCloud.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe S6 Mini is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSmall domestic roofs\u003c\/strong\u003e\u003cspan\u003eSix to twelve panels on one pitch, where a larger inverter would spend most of the year loafing.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSingle-orientation arrays\u003c\/strong\u003e\u003cspan\u003eOne MPPT is the right answer when every panel faces the same way and nothing shades them.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSystem top-ups\u003c\/strong\u003e\u003cspan\u003eAdding a second small array on its own inverter rather than re-engineering an existing string.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGarden rooms and outbuildings\u003c\/strong\u003e\u003cspan\u003eIP66 and 7.4 kg means it mounts where the array is, not where the house is.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRental and social housing\u003c\/strong\u003e\u003cspan\u003eLow capital cost per installed kWp on the roof sizes that dominate the housing stock.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLandlord and portfolio rollouts\u003c\/strong\u003e\u003cspan\u003eBought by the pallet, the per-unit cost drops again.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThis inverter can be reduced in power by agreement with the energy supplier to comply with balcony power plant regulations where those apply. The Manufacturer Power Limit Declaration issued by Solis, filed under Documents, must be completed and sent to the supplier. The inverter must also be connected with at least 2.5 mm² in the distribution. Refer to the manual when setting it up.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis S6-GR1P0.7K-M technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e1.1 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum DC input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated DC voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e60 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e14 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e22 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e0.7 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e0.77 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e0.77 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e3.2 A \/ 3.0 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e4.4 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e96.6 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e95.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e7.4 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e1\/N\/PE, 220 V \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;1 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e310 × 373 × 160 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−25 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC connection\u003c\/span\u003e\u003cstrong\u003eMC4 connector\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC connection\u003c\/span\u003e\u003cstrong\u003eQuick connection plug\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDisplay\u003c\/span\u003e\u003cstrong\u003eLCD\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; Wi-Fi and GPRS optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG98 or G99, VDE-AR-N 4105 \/ VDE V 0124, EN 50549-1, VDE 0126 \/ UTE C 15 \/ VFR:2019, RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1, CEI 0-21, C10\/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-1\/-2\/-3\/-4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet S6-GR1P(0.7-3.6)K-M - EN\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-0-7-mini-s6-dc\"\u003eS6 0.7kW Mini Single Tracker with DC isolator\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-s2-wl-st-usb\"\u003eSolis Data Logging Stick - Wi-Fi \u0026amp; LAN USB\u003c\/a\u003e\u003cspan\u003eThe datalogger. Not in the box, and needed for SolisCloud monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-ct-100a-10m\"\u003eCurrent Transformer for Solis 4G, 5G and S6 range 100A 10m\u003c\/a\u003e\u003cspan\u003eThe CT for export limitation and consumption monitoring within 10 m of the supply.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWill this work on a north-east or north-west facing roof?\u003c\/summary\u003e\u003cp\u003eYes, and the low start-up voltage is why. It will not turn a poor roof into a good one, but it will harvest the shoulders of the day that a higher-threshold inverter misses.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eOne MPPT — does that limit me?\u003c\/summary\u003e\u003cp\u003eIt limits you to one orientation and one string. If your array is split across two pitches, or is partly shaded, choose the dual-MPPT S6 range instead and put each pitch on its own tracker.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDoes it come with a DC isolator?\u003c\/summary\u003e\u003cp\u003eThe models we stock do, integrated in the unit. That removes a separate enclosure from the install and a component from the bill.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it G99 approved?\u003c\/summary\u003e\u003cp\u003eYes. G98 and G99 certificates are attached to this listing in the Documents tab, along with the EN 50549-1 declaration.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery later?\u003c\/summary\u003e\u003cp\u003eNot to this inverter — it is grid-tied only, with no battery port. You would either add an AC-coupled battery system alongside it, or replace it with a hybrid. We are happy to talk that through before you buy.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty comes with it?\u003c\/summary\u003e\u003cp\u003eFive years as standard, extendable to 10, 15 or 20 years. Registration terms are in the Solis warranty document attached to this listing.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":57440929317196,"sku":"SOL-0.7-MINI-S6-DC-5","price":754.12,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-0.7-MINI-S6-DC-5.jpg?v=1778196273"},{"product_id":"sol-1-0-mini-s6-dc-5","title":"Solis 1.0kW Mini S6 Single Tracker with DC isolator (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · S6 Mini\u003c\/div\u003e\n    \u003ch2\u003eSolis 1.0kW Mini S6 Single Tracker with DC isolator (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis S6 Mini\u003c\/strong\u003e — The small single-tracker inverter that makes a modest roof worth doing.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e1 kW\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e1.5 kW\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e96.6 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e600 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x S6 Mini 1kW 1MPPT 1PH Inverter - with DC isolator (\u003ca href=\"\/products\/SOL-1.0-MINI-S6-DC\"\u003eSOL-1.0-MINI-S6-DC\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-1.0-MINI-S6-DC-10\"\u003eSolis 1.0kW Mini S6 Single Tracker with DC isolator (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-1.0-MINI-S6-DC-24\"\u003eSolis 1.0kW Mini S6 Single Tracker with DC isolator (Pack of 24 - 1 pallet)\u003c\/a\u003e \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis S6 Mini\u003c\/h2\u003e\n    \u003cp\u003eMost UK roofs that get turned down for solar are turned down for the same reason: one usable pitch, room for six or eight panels, and a quote built around an inverter designed for twice that array. The Solis S6 Mini exists for exactly those roofs. It is a single-MPPT, single-phase string inverter in seven power steps from 0.7 kW to 3.6 kW, so the inverter can be sized to the array rather than the array sized to the inverter.\u003c\/p\u003e\n    \u003cp\u003eThe engineering that matters here is at the bottom of the power curve, not the top. A 60 V start-up voltage on the smaller models and an MPPT window that opens at 50 V means the inverter is awake and exporting on a dull February morning, when a higher-threshold unit is still sitting at zero. Over a UK year that low-light behaviour is worth more than a tenth of a percent on peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eIt is also genuinely small — 310 × 373 × 160 mm and 7.4 kg — which matters more than the spec sheet suggests. It goes on a garage wall, in a loft, or in a cupboard without a second pair of hands, and it is rated IP66 so it can equally live outside.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eIntegrated AFCI (activation required) and an optional integrated DC switch — the SKUs we stock are the DC-isolator versions, so there is no separate isolator to buy, mount and wire.\u003c\/li\u003e\n        \u003cli\u003eG98 and G99 certified, with EN 50549-1 and VDE-AR-N 4105 on the same sheet, so the DNO paperwork is straightforward on either route.\u003c\/li\u003e\n        \u003cli\u003eIntegrated Export Power Manager, so an export limit can be set without an external EPM box.\u003c\/li\u003e\n        \u003cli\u003eRS485 as standard with Wi-Fi and GPRS dataloggers optional, all reporting into SolisCloud.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe S6 Mini is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSmall domestic roofs\u003c\/strong\u003e\u003cspan\u003eSix to twelve panels on one pitch, where a larger inverter would spend most of the year loafing.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSingle-orientation arrays\u003c\/strong\u003e\u003cspan\u003eOne MPPT is the right answer when every panel faces the same way and nothing shades them.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSystem top-ups\u003c\/strong\u003e\u003cspan\u003eAdding a second small array on its own inverter rather than re-engineering an existing string.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGarden rooms and outbuildings\u003c\/strong\u003e\u003cspan\u003eIP66 and 7.4 kg means it mounts where the array is, not where the house is.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRental and social housing\u003c\/strong\u003e\u003cspan\u003eLow capital cost per installed kWp on the roof sizes that dominate the housing stock.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLandlord and portfolio rollouts\u003c\/strong\u003e\u003cspan\u003eBought by the pallet, the per-unit cost drops again.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThis inverter does not include a data logger or CT. For a single-inverter installation use CT SOL-CT-100A-10M; for more than one inverter use the EPM1. The CT requires a separate data logger. These items are sold separately.\u003c\/li\u003e\n        \u003cli\u003eThis inverter can be reduced in power by agreement with the energy supplier to comply with balcony power plant regulations where those apply. The Manufacturer Power Limit Declaration issued by Solis, filed under Documents, must be completed and sent to the supplier. The inverter must also be connected with at least 2.5 mm² in the distribution. Refer to the manual when setting it up.\u003c\/li\u003e\n        \u003cli\u003eThis product must be installed by a qualified electrician or technician. All installations must adhere to local wiring regulations and standards. ClearRay Solar will not be held liable for any product malfunctions as a result of incorrectly installed systems.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis S6-GR1P1K-M technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e1.5 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum DC input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated DC voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e60 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e14 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e22 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e1 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e1.1 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e1.1 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e4.5 A \/ 4.3 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e5.2 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e96.6 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e95.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e7.4 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e1\/N\/PE, 220 V \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;1 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e310 × 373 × 160 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−25 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC connection\u003c\/span\u003e\u003cstrong\u003eMC4 connector\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC connection\u003c\/span\u003e\u003cstrong\u003eQuick connection plug\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDisplay\u003c\/span\u003e\u003cstrong\u003eLCD\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; Wi-Fi and GPRS optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG98 or G99, VDE-AR-N 4105 \/ VDE V 0124, EN 50549-1, VDE 0126 \/ UTE C 15 \/ VFR:2019, RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1, CEI 0-21, C10\/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-1\/-2\/-3\/-4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet S6-GR1P(0.7-3.6)K-M - EN\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-1-0-mini-s6-dc\"\u003eS6 Mini 1kW 1MPPT 1PH Inverter - with DC isolator\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-s2-wl-st-usb\"\u003eSolis Data Logging Stick - Wi-Fi \u0026amp; LAN USB\u003c\/a\u003e\u003cspan\u003eThe datalogger. Not in the box, and needed for SolisCloud monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-ct-100a-10m\"\u003eCurrent Transformer for Solis 4G, 5G and S6 range 100A 10m\u003c\/a\u003e\u003cspan\u003eThe CT for export limitation and consumption monitoring within 10 m of the supply.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWill this work on a north-east or north-west facing roof?\u003c\/summary\u003e\u003cp\u003eYes, and the low start-up voltage is why. It will not turn a poor roof into a good one, but it will harvest the shoulders of the day that a higher-threshold inverter misses.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eOne MPPT — does that limit me?\u003c\/summary\u003e\u003cp\u003eIt limits you to one orientation and one string. If your array is split across two pitches, or is partly shaded, choose the dual-MPPT S6 range instead and put each pitch on its own tracker.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDoes it come with a DC isolator?\u003c\/summary\u003e\u003cp\u003eThe models we stock do, integrated in the unit. That removes a separate enclosure from the install and a component from the bill.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it G99 approved?\u003c\/summary\u003e\u003cp\u003eYes. G98 and G99 certificates are attached to this listing in the Documents tab, along with the EN 50549-1 declaration.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery later?\u003c\/summary\u003e\u003cp\u003eNot to this inverter — it is grid-tied only, with no battery port. You would either add an AC-coupled battery system alongside it, or replace it with a hybrid. We are happy to talk that through before you buy.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty comes with it?\u003c\/summary\u003e\u003cp\u003eFive years as standard, extendable to 10, 15 or 20 years. Registration terms are in the Solis warranty document attached to this listing.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":57440929644876,"sku":"SOL-1.0-MINI-S6-DC-5","price":764.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-1.0-MINI-S6-DC-5.jpg?v=1778196276"},{"product_id":"sol-1-5-mini-s6-dc-5","title":"Solis 1.5kW Mini S6 Single Tracker with DC isolator (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · S6 Mini\u003c\/div\u003e\n    \u003ch2\u003eSolis 1.5kW Mini S6 Single Tracker with DC isolator (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis S6 Mini\u003c\/strong\u003e — The small single-tracker inverter that makes a modest roof worth doing.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e1.5 kW\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e2.3 kW\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e96.6 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e600 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x S6 Mini 1.5kW 1MPPT 1PH Inverter - with DC isolator (\u003ca href=\"\/products\/SOL-1.5-MINI-S6-DC\"\u003eSOL-1.5-MINI-S6-DC\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-1.5-MINI-S6-DC-10\"\u003eSolis 1.5kW Mini S6 Single Tracker with DC isolator (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-1.5-MINI-S6-DC-24\"\u003eSolis 1.5kW Mini S6 Single Tracker with DC isolator (1x Pallet)\u003c\/a\u003e \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis S6 Mini\u003c\/h2\u003e\n    \u003cp\u003eMost UK roofs that get turned down for solar are turned down for the same reason: one usable pitch, room for six or eight panels, and a quote built around an inverter designed for twice that array. The Solis S6 Mini exists for exactly those roofs. It is a single-MPPT, single-phase string inverter in seven power steps from 0.7 kW to 3.6 kW, so the inverter can be sized to the array rather than the array sized to the inverter.\u003c\/p\u003e\n    \u003cp\u003eThe engineering that matters here is at the bottom of the power curve, not the top. A 60 V start-up voltage on the smaller models and an MPPT window that opens at 50 V means the inverter is awake and exporting on a dull February morning, when a higher-threshold unit is still sitting at zero. Over a UK year that low-light behaviour is worth more than a tenth of a percent on peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eIt is also genuinely small — 310 × 373 × 160 mm and 7.4 kg — which matters more than the spec sheet suggests. It goes on a garage wall, in a loft, or in a cupboard without a second pair of hands, and it is rated IP66 so it can equally live outside.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eIntegrated AFCI (activation required) and an optional integrated DC switch — the SKUs we stock are the DC-isolator versions, so there is no separate isolator to buy, mount and wire.\u003c\/li\u003e\n        \u003cli\u003eG98 and G99 certified, with EN 50549-1 and VDE-AR-N 4105 on the same sheet, so the DNO paperwork is straightforward on either route.\u003c\/li\u003e\n        \u003cli\u003eIntegrated Export Power Manager, so an export limit can be set without an external EPM box.\u003c\/li\u003e\n        \u003cli\u003eRS485 as standard with Wi-Fi and GPRS dataloggers optional, all reporting into SolisCloud.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe S6 Mini is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSmall domestic roofs\u003c\/strong\u003e\u003cspan\u003eSix to twelve panels on one pitch, where a larger inverter would spend most of the year loafing.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSingle-orientation arrays\u003c\/strong\u003e\u003cspan\u003eOne MPPT is the right answer when every panel faces the same way and nothing shades them.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSystem top-ups\u003c\/strong\u003e\u003cspan\u003eAdding a second small array on its own inverter rather than re-engineering an existing string.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGarden rooms and outbuildings\u003c\/strong\u003e\u003cspan\u003eIP66 and 7.4 kg means it mounts where the array is, not where the house is.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRental and social housing\u003c\/strong\u003e\u003cspan\u003eLow capital cost per installed kWp on the roof sizes that dominate the housing stock.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLandlord and portfolio rollouts\u003c\/strong\u003e\u003cspan\u003eBought by the pallet, the per-unit cost drops again.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis S6-GR1P1.5K-M technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e2.3 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum DC input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated DC voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e60 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e14 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e22 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e1.5 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e1.65 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e1.65 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e6.8 A \/ 6.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e8.1 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e96.6 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e95.4 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e7.4 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e1\/N\/PE, 220 V \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;1 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e310 × 373 × 160 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−25 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC connection\u003c\/span\u003e\u003cstrong\u003eMC4 connector\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC connection\u003c\/span\u003e\u003cstrong\u003eQuick connection plug\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDisplay\u003c\/span\u003e\u003cstrong\u003eLCD\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; Wi-Fi and GPRS optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG98 or G99, VDE-AR-N 4105 \/ VDE V 0124, EN 50549-1, VDE 0126 \/ UTE C 15 \/ VFR:2019, RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1, CEI 0-21, C10\/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-1\/-2\/-3\/-4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet S6-GR1P(0.7-3.6)K-M - EN\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-1-5-mini-s6-dc\"\u003eS6 Mini 1.5kW 1MPPT 1PH Inverter - with DC isolator\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-s2-wl-st-usb\"\u003eSolis Data Logging Stick - Wi-Fi \u0026amp; LAN USB\u003c\/a\u003e\u003cspan\u003eThe datalogger. Not in the box, and needed for SolisCloud monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-ct-100a-10m\"\u003eCurrent Transformer for Solis 4G, 5G and S6 range 100A 10m\u003c\/a\u003e\u003cspan\u003eThe CT for export limitation and consumption monitoring within 10 m of the supply.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWill this work on a north-east or north-west facing roof?\u003c\/summary\u003e\u003cp\u003eYes, and the low start-up voltage is why. It will not turn a poor roof into a good one, but it will harvest the shoulders of the day that a higher-threshold inverter misses.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eOne MPPT — does that limit me?\u003c\/summary\u003e\u003cp\u003eIt limits you to one orientation and one string. If your array is split across two pitches, or is partly shaded, choose the dual-MPPT S6 range instead and put each pitch on its own tracker.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDoes it come with a DC isolator?\u003c\/summary\u003e\u003cp\u003eThe models we stock do, integrated in the unit. That removes a separate enclosure from the install and a component from the bill.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it G99 approved?\u003c\/summary\u003e\u003cp\u003eYes. G98 and G99 certificates are attached to this listing in the Documents tab, along with the EN 50549-1 declaration.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery later?\u003c\/summary\u003e\u003cp\u003eNot to this inverter — it is grid-tied only, with no battery port. You would either add an AC-coupled battery system alongside it, or replace it with a hybrid. We are happy to talk that through before you buy.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty comes with it?\u003c\/summary\u003e\u003cp\u003eFive years as standard, extendable to 10, 15 or 20 years. Registration terms are in the Solis warranty document attached to this listing.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":57440929775948,"sku":"SOL-1.5-MINI-S6-DC-5","price":869.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-1.5-MINI-S6-DC-5.jpg?v=1778196279"},{"product_id":"sol-100k-5g-pro-dc-4","title":"5G PRO 100kW 3PH Inverter (Pack of 4)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · 5G PRO Commercial Three Phase\u003c\/div\u003e\n    \u003ch2\u003e5G PRO 100kW 3PH Inverter (Pack of 4)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis 5G PRO Commercial Three Phase\u003c\/strong\u003e — 80 kW to 110 kW built for 182 mm and 210 mm modules, up to 18 A per string.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 4\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e100 kW\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e8\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.5 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e1,100 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e160 – 1,000 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 4 x 5G PRO 100kW 3PH Inverter with 8x MPPT (\u003ca href=\"\/products\/SOL-100K-5G-PRO-DC\"\u003eSOL-100K-5G-PRO-DC\u003c\/a\u003e)\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis 5G PRO Commercial Three Phase\u003c\/h2\u003e\n    \u003cp\u003eThe 5G PRO is Solis's answer to the same shift the S6-GC addresses — large-format cells and higher string currents — from the previous platform generation. Where it wins is on cost per installed kilowatt: it takes 16 to 18 A per string, supports aluminium AC cable, and accepts a DC\/AC ratio above 150 %, all of which pull money out of the balance of system rather than out of the inverter.\u003c\/p\u003e\n    \u003cp\u003eSix or eight MPP trackers, a 160 – 1,000 V MPPT window and a 1,100 V system voltage give the design freedom that a commercial roof needs, and the night SVG function lets the unit provide reactive power support after dark, which some DNO connection agreements now ask for.\u003c\/p\u003e\n    \u003cp\u003eIt is IP66, fan cooled, and carries an integrated DC switch as standard, so it lands on site ready to wire.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003e6 or 8 MPP trackers; 12 or 16 strings; 36 A \/ 32 A alternating per tracker.\u003c\/li\u003e\n        \u003cli\u003eIntegrated DC switch as standard; AFCI available (activation required).\u003c\/li\u003e\n        \u003cli\u003eAluminium AC cable supported — a material saving at 110 kW.\u003c\/li\u003e\n        \u003cli\u003eNight SVG function for reactive power support outside generating hours.\u003c\/li\u003e\n        \u003cli\u003eDC side supports Y connectors. Optional power line communication.\u003c\/li\u003e\n        \u003cli\u003eCertified to G99 and IEC 61727.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe 5G PRO Commercial Three Phase is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLarge commercial rooftops\u003c\/strong\u003e\u003cspan\u003e80 kW to 110 kW per unit, several units per site.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGround mount arrays\u003c\/strong\u003e\u003cspan\u003eWide MPPT window and high string current suit long rows.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eBifacial and large-format modules\u003c\/strong\u003e\u003cspan\u003e16 to 18 A per string is the design headroom these modules need.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites with reactive power obligations\u003c\/strong\u003e\u003cspan\u003eNight SVG keeps the connection agreement satisfied after dark.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCost-driven tenders\u003c\/strong\u003e\u003cspan\u003eAluminium AC cable support and high DC\/AC ratio lower the installed cost per kWp.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003ePlease be aware you may receive stock with either 36 A \/ 32 A or 40 A \/ 32 A MPPTs.\u003c\/li\u003e\n        \u003cli\u003eThis inverter comes with integrated DC isolators but not the AC option. An AC isolator is required and is not supplied.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis Solis-100K-5G-PRO technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e36 A \/ 32 A × 4 pairs\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e8 × 50 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e16\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e100 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e110 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e110 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e152.0 A \/ 144.3 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e167.1 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e93 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e1,100 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e180 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e160 – 1,000 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e3\/N\/PE, 220 V \/ 380 V, 230 V \/ 400 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.5 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEU efficiency\u003c\/span\u003e\u003cstrong\u003e98 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e1,183 × 585 × 363 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−30 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eIntelligent redundant fan-cooling\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSurge protection\u003c\/span\u003e\u003cstrong\u003eDC Type II \/ AC Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStrings monitoring\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eI-V curve scanning\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated DC switch\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG99, IEC 61727\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-2\/-4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SOL-(80-110)K-5G-PRO - EN\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-100k-5g-pro-dc\"\u003e5G PRO 100kW 3PH Inverter with 8x MPPT\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-epm3-5g-pro\"\u003eSolis Export Power Manager EPM3-5G-PRO\u003c\/a\u003e\u003cspan\u003eExport Power Manager with a built-in datalogger.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-s2-wl-st-usb\"\u003eSolis Data Logging Stick - Wi-Fi \u0026amp; LAN USB\u003c\/a\u003e\u003cspan\u003eWi-Fi and LAN datalogging stick, USB.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eHow does this differ from the S6-GC range?\u003c\/summary\u003e\u003cp\u003eThe S6-GC is the newer platform with up to ten trackers and 21 A per string. The 5G PRO is the previous generation, still current, with six or eight trackers and 16 to 18 A. If you are extending a site that already runs 5G PRO units, matching them keeps monitoring and spares consistent.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is night SVG?\u003c\/summary\u003e\u003cp\u003eStatic VAr generation: the inverter supplies or absorbs reactive power at night when it is not generating. Some DNO connection offers require it on larger connections.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I use aluminium AC cable?\u003c\/summary\u003e\u003cp\u003eYes, the terminals are rated for it. At 110 kW that is a genuine saving over copper.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":57440930136396,"sku":"SOL-100K-5G-PRO-DC-4","price":11224.65,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-100K-5G-PRO-DC-4.jpg?v=1778196282"},{"product_id":"sol-110k-5g-pro-dc-4","title":"5G PRO 110kW 3ph Inverter (Pack of 4)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · 5G PRO Commercial Three Phase\u003c\/div\u003e\n    \u003ch2\u003e5G PRO 110kW 3ph Inverter (Pack of 4)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis 5G PRO Commercial Three Phase\u003c\/strong\u003e — 80 kW to 110 kW built for 182 mm and 210 mm modules, up to 18 A per string.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 4\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e110 kW\u003c\/strong\u003e\u003cspan\u003eThree phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e8\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e98.5 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e1,100 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e160 – 1,000 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 4 x 5G PRO 110kW 3-Phase Inverter with 8x MPPT (\u003ca href=\"\/products\/SOL-110K-5G-PRO-DC\"\u003eSOL-110K-5G-PRO-DC\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-110K-5G-PRO-DC-10\"\u003e5G PRO 110kW 3ph Inverter (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis 5G PRO Commercial Three Phase\u003c\/h2\u003e\n    \u003cp\u003eThe 5G PRO is Solis's answer to the same shift the S6-GC addresses — large-format cells and higher string currents — from the previous platform generation. Where it wins is on cost per installed kilowatt: it takes 16 to 18 A per string, supports aluminium AC cable, and accepts a DC\/AC ratio above 150 %, all of which pull money out of the balance of system rather than out of the inverter.\u003c\/p\u003e\n    \u003cp\u003eSix or eight MPP trackers, a 160 – 1,000 V MPPT window and a 1,100 V system voltage give the design freedom that a commercial roof needs, and the night SVG function lets the unit provide reactive power support after dark, which some DNO connection agreements now ask for.\u003c\/p\u003e\n    \u003cp\u003eIt is IP66, fan cooled, and carries an integrated DC switch as standard, so it lands on site ready to wire.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003e6 or 8 MPP trackers; 12 or 16 strings; 36 A \/ 32 A alternating per tracker.\u003c\/li\u003e\n        \u003cli\u003eIntegrated DC switch as standard; AFCI available (activation required).\u003c\/li\u003e\n        \u003cli\u003eAluminium AC cable supported — a material saving at 110 kW.\u003c\/li\u003e\n        \u003cli\u003eNight SVG function for reactive power support outside generating hours.\u003c\/li\u003e\n        \u003cli\u003eDC side supports Y connectors. Optional power line communication.\u003c\/li\u003e\n        \u003cli\u003eCertified to G99 and IEC 61727.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe 5G PRO Commercial Three Phase is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLarge commercial rooftops\u003c\/strong\u003e\u003cspan\u003e80 kW to 110 kW per unit, several units per site.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGround mount arrays\u003c\/strong\u003e\u003cspan\u003eWide MPPT window and high string current suit long rows.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eBifacial and large-format modules\u003c\/strong\u003e\u003cspan\u003e16 to 18 A per string is the design headroom these modules need.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSites with reactive power obligations\u003c\/strong\u003e\u003cspan\u003eNight SVG keeps the connection agreement satisfied after dark.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eCost-driven tenders\u003c\/strong\u003e\u003cspan\u003eAluminium AC cable support and high DC\/AC ratio lower the installed cost per kWp.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003ePlease be aware you may receive stock with either 36 A \/ 32 A or 40 A \/ 32 A MPPTs.\u003c\/li\u003e\n        \u003cli\u003eThis inverter comes with integrated DC isolators but not the AC option. An AC isolator is required and is not supplied.\u003c\/li\u003e\n        \u003cli\u003eSouth Africa: all 110K inverters, or any combination of inverters whose total parallel power reaches or exceeds 100 kW, must be set with a ramp-up rate of 10 % per minute, as required by NRS 097-2-1:2017 Annex G1.3.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis Solis-110K-5G-PRO technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e36 A \/ 32 A × 4 pairs\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e8 × 50 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e8\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e16\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e110 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e121 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e121 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e167.1 A \/ 158.8 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e183.8 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e93 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003cstrong\u003e1,100 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e180 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e160 – 1,000 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e3\/N\/PE, 220 V \/ 380 V, 230 V \/ 400 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e98.5 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEU efficiency\u003c\/span\u003e\u003cstrong\u003e98 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;2 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e1,183 × 585 × 363 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−30 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eIntelligent redundant fan-cooling\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSurge protection\u003c\/span\u003e\u003cstrong\u003eDC Type II \/ AC Type II\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStrings monitoring\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eI-V curve scanning\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated DC switch\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG99, IEC 61727\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-2\/-4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet SOL-(80-110)K-5G-PRO - EN\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-110k-5g-pro-dc\"\u003e5G PRO 110kW 3-Phase Inverter with 8x MPPT\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-epm3-5g-pro\"\u003eSolis Export Power Manager EPM3-5G-PRO\u003c\/a\u003e\u003cspan\u003eExport Power Manager with a built-in datalogger.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-s2-wl-st-usb\"\u003eSolis Data Logging Stick - Wi-Fi \u0026amp; LAN USB\u003c\/a\u003e\u003cspan\u003eWi-Fi and LAN datalogging stick, USB.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eHow does this differ from the S6-GC range?\u003c\/summary\u003e\u003cp\u003eThe S6-GC is the newer platform with up to ten trackers and 21 A per string. The 5G PRO is the previous generation, still current, with six or eight trackers and 16 to 18 A. If you are extending a site that already runs 5G PRO units, matching them keeps monitoring and spares consistent.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat is night SVG?\u003c\/summary\u003e\u003cp\u003eStatic VAr generation: the inverter supplies or absorbs reactive power at night when it is not generating. Some DNO connection offers require it on larger connections.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I use aluminium AC cable?\u003c\/summary\u003e\u003cp\u003eYes, the terminals are rated for it. At 110 kW that is a genuine saving over copper.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":57440930267468,"sku":"SOL-110K-5G-PRO-DC-4","price":11565.35,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-110K-5G-PRO-DC-4_3f08d835-3e0a-4684-8c13-715d537e51f9.jpg?v=1778196284"},{"product_id":"sol-2-0-mini-s6-dc-5","title":"Solis 2.0kW Mini S6 Single Tracker with DC isolator (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · S6 Mini\u003c\/div\u003e\n    \u003ch2\u003eSolis 2.0kW Mini S6 Single Tracker with DC isolator (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis S6 Mini\u003c\/strong\u003e — The small single-tracker inverter that makes a modest roof worth doing.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e2 kW\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e3 kW\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e97.1 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e600 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x S6 Mini 2kW 1MPPT 1Ph Inverter - with DC isolator (\u003ca href=\"\/products\/SOL-2.0-MINI-S6-DC\"\u003eSOL-2.0-MINI-S6-DC\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-2.0-MINI-S6-DC-10\"\u003eSolis 2.0kW Mini S6 Single Tracker with DC isolator (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-2.0-MINI-S6-DC-24\"\u003eSolis 2.0kW Mini S6 Single Tracker with DC isolator (1 Pallet )\u003c\/a\u003e \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis S6 Mini\u003c\/h2\u003e\n    \u003cp\u003eMost UK roofs that get turned down for solar are turned down for the same reason: one usable pitch, room for six or eight panels, and a quote built around an inverter designed for twice that array. The Solis S6 Mini exists for exactly those roofs. It is a single-MPPT, single-phase string inverter in seven power steps from 0.7 kW to 3.6 kW, so the inverter can be sized to the array rather than the array sized to the inverter.\u003c\/p\u003e\n    \u003cp\u003eThe engineering that matters here is at the bottom of the power curve, not the top. A 60 V start-up voltage on the smaller models and an MPPT window that opens at 50 V means the inverter is awake and exporting on a dull February morning, when a higher-threshold unit is still sitting at zero. Over a UK year that low-light behaviour is worth more than a tenth of a percent on peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eIt is also genuinely small — 310 × 373 × 160 mm and 7.4 kg — which matters more than the spec sheet suggests. It goes on a garage wall, in a loft, or in a cupboard without a second pair of hands, and it is rated IP66 so it can equally live outside.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eIntegrated AFCI (activation required) and an optional integrated DC switch — the SKUs we stock are the DC-isolator versions, so there is no separate isolator to buy, mount and wire.\u003c\/li\u003e\n        \u003cli\u003eG98 and G99 certified, with EN 50549-1 and VDE-AR-N 4105 on the same sheet, so the DNO paperwork is straightforward on either route.\u003c\/li\u003e\n        \u003cli\u003eIntegrated Export Power Manager, so an export limit can be set without an external EPM box.\u003c\/li\u003e\n        \u003cli\u003eRS485 as standard with Wi-Fi and GPRS dataloggers optional, all reporting into SolisCloud.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe S6 Mini is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSmall domestic roofs\u003c\/strong\u003e\u003cspan\u003eSix to twelve panels on one pitch, where a larger inverter would spend most of the year loafing.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSingle-orientation arrays\u003c\/strong\u003e\u003cspan\u003eOne MPPT is the right answer when every panel faces the same way and nothing shades them.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSystem top-ups\u003c\/strong\u003e\u003cspan\u003eAdding a second small array on its own inverter rather than re-engineering an existing string.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGarden rooms and outbuildings\u003c\/strong\u003e\u003cspan\u003eIP66 and 7.4 kg means it mounts where the array is, not where the house is.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRental and social housing\u003c\/strong\u003e\u003cspan\u003eLow capital cost per installed kWp on the roof sizes that dominate the housing stock.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLandlord and portfolio rollouts\u003c\/strong\u003e\u003cspan\u003eBought by the pallet, the per-unit cost drops again.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThis product must be installed by a qualified electrician or technician. All installations must adhere to local wiring regulations and standards. ClearRay Solar will not be held liable for any product malfunctions as a result of incorrectly installed systems.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis S6-GR1P2K-M technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e3 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum DC input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated DC voltage\u003c\/span\u003e\u003cstrong\u003e200 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e60 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e50 – 500 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e14 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e22 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e2 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e2.2 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e2.2 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e9.1 A \/ 8.7 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e10.5 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e97.1 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e96.6 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e7.4 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e1\/N\/PE, 220 V \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;1 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e310 × 373 × 160 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−25 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC connection\u003c\/span\u003e\u003cstrong\u003eMC4 connector\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC connection\u003c\/span\u003e\u003cstrong\u003eQuick connection plug\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDisplay\u003c\/span\u003e\u003cstrong\u003eLCD\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; Wi-Fi and GPRS optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG98 or G99, VDE-AR-N 4105 \/ VDE V 0124, EN 50549-1, VDE 0126 \/ UTE C 15 \/ VFR:2019, RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1, CEI 0-21, C10\/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-1\/-2\/-3\/-4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet S6-GR1P(0.7-3.6)K-M - EN\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-2-0-mini-s6-dc\"\u003eS6 Mini 2kW 1MPPT 1Ph Inverter - with DC isolator\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-s2-wl-st-usb\"\u003eSolis Data Logging Stick - Wi-Fi \u0026amp; LAN USB\u003c\/a\u003e\u003cspan\u003eThe datalogger. Not in the box, and needed for SolisCloud monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-ct-100a-10m\"\u003eCurrent Transformer for Solis 4G, 5G and S6 range 100A 10m\u003c\/a\u003e\u003cspan\u003eThe CT for export limitation and consumption monitoring within 10 m of the supply.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWill this work on a north-east or north-west facing roof?\u003c\/summary\u003e\u003cp\u003eYes, and the low start-up voltage is why. It will not turn a poor roof into a good one, but it will harvest the shoulders of the day that a higher-threshold inverter misses.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eOne MPPT — does that limit me?\u003c\/summary\u003e\u003cp\u003eIt limits you to one orientation and one string. If your array is split across two pitches, or is partly shaded, choose the dual-MPPT S6 range instead and put each pitch on its own tracker.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDoes it come with a DC isolator?\u003c\/summary\u003e\u003cp\u003eThe models we stock do, integrated in the unit. That removes a separate enclosure from the install and a component from the bill.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it G99 approved?\u003c\/summary\u003e\u003cp\u003eYes. G98 and G99 certificates are attached to this listing in the Documents tab, along with the EN 50549-1 declaration.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery later?\u003c\/summary\u003e\u003cp\u003eNot to this inverter — it is grid-tied only, with no battery port. You would either add an AC-coupled battery system alongside it, or replace it with a hybrid. We are happy to talk that through before you buy.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty comes with it?\u003c\/summary\u003e\u003cp\u003eFive years as standard, extendable to 10, 15 or 20 years. Registration terms are in the Solis warranty document attached to this listing.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":57440931545420,"sku":"SOL-2.0-MINI-S6-DC-5","price":944.56,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-2.0-MINI-S6-DC-5.jpg?v=1778196287"},{"product_id":"sol-2-5-mini-s6-dc-5","title":"Solis 2.5kW Mini S6 Single Tracker with DC isolator (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · S6 Mini\u003c\/div\u003e\n    \u003ch2\u003eSolis 2.5kW Mini S6 Single Tracker with DC isolator (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis S6 Mini\u003c\/strong\u003e — The small single-tracker inverter that makes a modest roof worth doing.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e2.5 kW\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e3.8 kW\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e97.1 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e600 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e80 – 500 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x S6 Mini 2.5kW 1MPPT 1PH Inverter - with DC isolator (\u003ca href=\"\/products\/SOL-2.5-MINI-S6-DC\"\u003eSOL-2.5-MINI-S6-DC\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-2.5-MINI-S6-DC-10\"\u003eSolis 2.5kW Mini S6 Single Tracker with DC isolator (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-2.5-MINI-S6-DC-24\"\u003eSolis 2.5kW Mini S6 Single Tracker with DC isolator (1x Pallet)\u003c\/a\u003e \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis S6 Mini\u003c\/h2\u003e\n    \u003cp\u003eMost UK roofs that get turned down for solar are turned down for the same reason: one usable pitch, room for six or eight panels, and a quote built around an inverter designed for twice that array. The Solis S6 Mini exists for exactly those roofs. It is a single-MPPT, single-phase string inverter in seven power steps from 0.7 kW to 3.6 kW, so the inverter can be sized to the array rather than the array sized to the inverter.\u003c\/p\u003e\n    \u003cp\u003eThe engineering that matters here is at the bottom of the power curve, not the top. A 60 V start-up voltage on the smaller models and an MPPT window that opens at 50 V means the inverter is awake and exporting on a dull February morning, when a higher-threshold unit is still sitting at zero. Over a UK year that low-light behaviour is worth more than a tenth of a percent on peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eIt is also genuinely small — 310 × 373 × 160 mm and 7.4 kg — which matters more than the spec sheet suggests. It goes on a garage wall, in a loft, or in a cupboard without a second pair of hands, and it is rated IP66 so it can equally live outside.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eIntegrated AFCI (activation required) and an optional integrated DC switch — the SKUs we stock are the DC-isolator versions, so there is no separate isolator to buy, mount and wire.\u003c\/li\u003e\n        \u003cli\u003eG98 and G99 certified, with EN 50549-1 and VDE-AR-N 4105 on the same sheet, so the DNO paperwork is straightforward on either route.\u003c\/li\u003e\n        \u003cli\u003eIntegrated Export Power Manager, so an export limit can be set without an external EPM box.\u003c\/li\u003e\n        \u003cli\u003eRS485 as standard with Wi-Fi and GPRS dataloggers optional, all reporting into SolisCloud.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe S6 Mini is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSmall domestic roofs\u003c\/strong\u003e\u003cspan\u003eSix to twelve panels on one pitch, where a larger inverter would spend most of the year loafing.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSingle-orientation arrays\u003c\/strong\u003e\u003cspan\u003eOne MPPT is the right answer when every panel faces the same way and nothing shades them.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSystem top-ups\u003c\/strong\u003e\u003cspan\u003eAdding a second small array on its own inverter rather than re-engineering an existing string.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGarden rooms and outbuildings\u003c\/strong\u003e\u003cspan\u003eIP66 and 7.4 kg means it mounts where the array is, not where the house is.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRental and social housing\u003c\/strong\u003e\u003cspan\u003eLow capital cost per installed kWp on the roof sizes that dominate the housing stock.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLandlord and portfolio rollouts\u003c\/strong\u003e\u003cspan\u003eBought by the pallet, the per-unit cost drops again.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis S6-GR1P2.5K-M technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e3.8 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum DC input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated DC voltage\u003c\/span\u003e\u003cstrong\u003e330 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e90 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e80 – 500 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e19 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e30 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e2.5 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e2.75 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e2.75 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e11.4 A \/ 10.9 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e13.3 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e97.1 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e96.7 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e7.7 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e1\/N\/PE, 220 V \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;1 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e310 × 373 × 160 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−25 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC connection\u003c\/span\u003e\u003cstrong\u003eMC4 connector\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC connection\u003c\/span\u003e\u003cstrong\u003eQuick connection plug\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDisplay\u003c\/span\u003e\u003cstrong\u003eLCD\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; Wi-Fi and GPRS optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG98 or G99, VDE-AR-N 4105 \/ VDE V 0124, EN 50549-1, VDE 0126 \/ UTE C 15 \/ VFR:2019, RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1, CEI 0-21, C10\/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-1\/-2\/-3\/-4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet S6-GR1P(0.7-3.6)K-M - EN\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-2-5-mini-s6-dc\"\u003eS6 Mini 2.5kW 1MPPT 1PH Inverter - with DC isolator\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-s2-wl-st-usb\"\u003eSolis Data Logging Stick - Wi-Fi \u0026amp; LAN USB\u003c\/a\u003e\u003cspan\u003eThe datalogger. Not in the box, and needed for SolisCloud monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-ct-100a-10m\"\u003eCurrent Transformer for Solis 4G, 5G and S6 range 100A 10m\u003c\/a\u003e\u003cspan\u003eThe CT for export limitation and consumption monitoring within 10 m of the supply.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWill this work on a north-east or north-west facing roof?\u003c\/summary\u003e\u003cp\u003eYes, and the low start-up voltage is why. It will not turn a poor roof into a good one, but it will harvest the shoulders of the day that a higher-threshold inverter misses.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eOne MPPT — does that limit me?\u003c\/summary\u003e\u003cp\u003eIt limits you to one orientation and one string. If your array is split across two pitches, or is partly shaded, choose the dual-MPPT S6 range instead and put each pitch on its own tracker.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDoes it come with a DC isolator?\u003c\/summary\u003e\u003cp\u003eThe models we stock do, integrated in the unit. That removes a separate enclosure from the install and a component from the bill.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it G99 approved?\u003c\/summary\u003e\u003cp\u003eYes. G98 and G99 certificates are attached to this listing in the Documents tab, along with the EN 50549-1 declaration.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery later?\u003c\/summary\u003e\u003cp\u003eNot to this inverter — it is grid-tied only, with no battery port. You would either add an AC-coupled battery system alongside it, or replace it with a hybrid. We are happy to talk that through before you buy.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty comes with it?\u003c\/summary\u003e\u003cp\u003eFive years as standard, extendable to 10, 15 or 20 years. Registration terms are in the Solis warranty document attached to this listing.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":57440932168012,"sku":"SOL-2.5-MINI-S6-DC-5","price":957.96,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-2.5-MINI-S6-DC-5.jpg?v=1778196290"},{"product_id":"sol-2-5-s6-dt-dc-5","title":"Solis 2.5kW S6 Dual MPPT - Single Phase with DC (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · S6 Dual MPPT\u003c\/div\u003e\n    \u003ch2\u003eSolis 2.5kW S6 Dual MPPT - Single Phase with DC (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis S6 Dual MPPT\u003c\/strong\u003e — Two trackers, so a split roof stops costing you generation.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e2.5 kW\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e3.75 kW\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e97.3 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e550 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e50 – 450 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x S6 2.5kW Dual MPPT - Single Phase with DC (\u003ca href=\"\/products\/SOL-2.5-S6-DT-DC\"\u003eSOL-2.5-S6-DT-DC\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-2.5-S6-DT-DC-10\"\u003eS6 2.5kW 2MPPT 1PH Inverter - with DC (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-2.5-S6-DT-DC-16\"\u003eS6 2.5kW 2MPPT 1PH Inverter - with DC (1x Pallet)\u003c\/a\u003e \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis S6 Dual MPPT\u003c\/h2\u003e\n    \u003cp\u003eA second MPP tracker is the single most useful upgrade on a British roof, and the reason is geometry rather than electronics. Very few UK houses offer one clean, unshaded, south-facing pitch. Most offer two pitches at different angles, or one pitch with a chimney, a dormer or a neighbour's tree across part of it. Wire that array as a single string and every panel is dragged down to the performance of the worst one.\u003c\/p\u003e\n    \u003cp\u003eThe Solis S6 Dual MPPT range gives each pitch, or each shaded group, its own tracker and its own maximum power point. East and west arrays generate independently across the day, and a shaded group no longer taxes the clear one. In practice that is the difference between a roof being worth doing and being marginal.\u003c\/p\u003e\n    \u003cp\u003eThe range runs from 2.5 kW to 6 kW in seven steps, all in the same 310 × 543 × 160 mm case at 11 to 12 kg, all IP66, and all with integrated AFCI arc-fault detection. The larger models accept up to 14 A per tracker, which is enough headroom for current large-format and bifacial modules rather than only for the 400 W panels of a few years ago.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eTwo independent MPP trackers, one string each, 14 A per tracker — sized for modern high-current modules including bifacial.\u003c\/li\u003e\n        \u003cli\u003eIntegrated AFCI (activation required) and integrated Export Power Manager.\u003c\/li\u003e\n        \u003cli\u003eThe SKUs we stock include the integrated DC switch, so no separate rooftop or wall isolator is needed.\u003c\/li\u003e\n        \u003cli\u003eG98 and G99 certified with EN 50549-1; the certificates are attached to the listing.\u003c\/li\u003e\n        \u003cli\u003eThe 4 kW to 6 kW models start at 120 V with a 90 – 520 V MPPT window; the 2.5 kW and 3 kW start at 60 V with a 50 – 450 V window, which allows notably shorter strings on small pitches.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe S6 Dual MPPT is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eEast–west split roofs\u003c\/strong\u003e\u003cspan\u003eOne tracker per pitch, generating independently morning and evening.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003ePartly shaded arrays\u003c\/strong\u003e\u003cspan\u003eIsolate the shaded group on its own tracker so it cannot pull the clear string down.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eMixed panel counts\u003c\/strong\u003e\u003cspan\u003eTwo strings of unequal length are fine when each has its own tracker.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eStandard 4 kW domestic installs\u003c\/strong\u003e\u003cspan\u003eThe 3.6 kW and 4 kW models are the volume choice for a typical UK semi.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRetrofit and extension\u003c\/strong\u003e\u003cspan\u003eAdd a second orientation to an existing array without redesigning the first.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eTrade rollouts\u003c\/strong\u003e\u003cspan\u003ePallet quantities available for installers running repeat house types.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThis product must be installed by a qualified electrician or technician. All installations must adhere to local wiring regulations and standards. ClearRay Solar will not be held liable for any product malfunctions as a result of incorrectly installed systems.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis S6-GR1P2.5K technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e3.75 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum DC input voltage\u003c\/span\u003e\u003cstrong\u003e550 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated DC voltage\u003c\/span\u003e\u003cstrong\u003e250 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e60 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e50 – 450 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e2.5 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e2.8 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e2.8 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e11.4 A \/ 10.9 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e13.3 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e97.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e96.5 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e11 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e2, one per tracker\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e14 A \/ 14 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e22 A \/ 22 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e1\/N\/PE, 220 V \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;1 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e310 × 543 × 160 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−25 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC connection\u003c\/span\u003e\u003cstrong\u003eMC4 connector\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC connection\u003c\/span\u003e\u003cstrong\u003eQuick connection plug\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDisplay\u003c\/span\u003e\u003cstrong\u003eLCD\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; Wi-Fi and GPRS optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG98 or G99, VDE-AR-N 4105 \/ VDE V 0124, EN 50549-1, VDE 0126 \/ UTE C 15 \/ VFR:2019, RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1, CEI 0-21, C10\/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-2\/-3\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet Solis S6-GR1P(2.5-6)K\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-2-5-s6-dt-dc\"\u003eS6 2.5kW Dual MPPT - Single Phase with DC\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-s2-wl-st-usb\"\u003eSolis Data Logging Stick - Wi-Fi \u0026amp; LAN USB\u003c\/a\u003e\u003cspan\u003eThe datalogger. Not in the box, and needed for SolisCloud monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-ct-100a-10m\"\u003eCurrent Transformer for Solis 4G, 5G and S6 range 100A 10m\u003c\/a\u003e\u003cspan\u003eThe CT for export limitation within 10 m of the supply. Beyond that, use the EPM.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat does a second MPPT actually gain me?\u003c\/summary\u003e\u003cp\u003eOn a genuinely single-orientation, unshaded roof, nothing. On a split or partly shaded roof it is typically a double-digit percentage of annual yield, because each string finds its own optimum instead of being averaged with the other.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I put both strings on one tracker?\u003c\/summary\u003e\u003cp\u003eYou can, but then you have bought a dual-tracker inverter and used it as a single. If both pitches face the same way with the same shading it makes no difference; if they do not, split them.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDo I still need optimisers?\u003c\/summary\u003e\u003cp\u003eUsually not. Two trackers handle two orientations or one shaded group. Optimisers earn their money when shading is per-panel and moves across the array — a chimney shadow tracking across a roof through the day, for instance.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs the DC isolator included?\u003c\/summary\u003e\u003cp\u003eYes on the models we stock. It is integrated in the inverter.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it battery ready?\u003c\/summary\u003e\u003cp\u003eNo. This is a grid-tied PV inverter with no battery port. If storage is on the roadmap, either plan an AC-coupled battery or choose a hybrid inverter now.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eHow loud is it?\u003c\/summary\u003e\u003cp\u003eIt is convection cooled with no fan, so effectively silent. It can go on a hallway or bedroom wall without complaint.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":57440932528460,"sku":"SOL-2.5-S6-DT-DC-5","price":1218.26,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-2.5-S6-DT-DC-5.jpg?v=1778196293"},{"product_id":"sol-3-0-mini-s6-dc-5","title":"Solis 3.0kW Mini S6 Single Tracker with DC isolator (Pack of 5)","description":"\u003cdiv class=\"cr-pdp\"\u003e\n\n  \u003csection class=\"cr-hero\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eSolis · S6 Mini\u003c\/div\u003e\n    \u003ch2\u003eSolis 3.0kW Mini S6 Single Tracker with DC isolator (Pack of 5)\u003c\/h2\u003e\n    \u003cp class=\"cr-sub\"\u003e\u003cstrong\u003eSolis S6 Mini\u003c\/strong\u003e — The small single-tracker inverter that makes a modest roof worth doing.\u003c\/p\u003e\n      \u003cp\u003eThis listing is a \u003cstrong\u003epack of 5\u003c\/strong\u003e of this inverter, priced for installers buying in volume. Everything below describes the unit itself.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-specgrid\"\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eRated output\u003c\/div\u003e\n\u003cstrong\u003e3 kW\u003c\/strong\u003e\u003cspan\u003eSingle phase AC output\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum PV input\u003c\/div\u003e\n\u003cstrong\u003e4.5 kW\u003c\/strong\u003e\u003cspan\u003eArray size this inverter accepts\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPP trackers\u003c\/div\u003e\n\u003cstrong\u003e1\u003c\/strong\u003e\u003cspan\u003eIndependent maximum power point trackers\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003ePeak efficiency\u003c\/div\u003e\n\u003cstrong\u003e97.3 %\u003c\/strong\u003e\u003cspan\u003eConversion efficiency at best\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMaximum DC voltage\u003c\/div\u003e\n\u003cstrong\u003e600 V\u003c\/strong\u003e\u003cspan\u003eString voltage ceiling\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eMPPT window\u003c\/div\u003e\n\u003cstrong\u003e80 – 500 V\u003c\/strong\u003e\u003cspan\u003eWhere it tracks\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eProtection rating\u003c\/div\u003e\n\u003cstrong\u003eIP66\u003c\/strong\u003e\u003cspan\u003eIndoor or outdoor mounting\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"cr-speccard\"\u003e\n\u003cdiv class=\"cr-lbl\"\u003eWarranty\u003c\/div\u003e\n\u003cstrong\u003e5 years\u003c\/strong\u003e\u003cspan\u003eStandard, extendable to 10, 15 or 20 years\u003c\/span\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eImportant\u003c\/div\u003e\n    \u003ch2\u003ePlease read before ordering\u003c\/h2\u003e\n    \u003cdiv class=\"bulkPackText\"\u003eThis is a bulk pack of 5 x S6 Mini 3kW 1MPPT 1Ph Inverter - with DC isolator (\u003ca href=\"\/products\/SOL-3.0-MINI-S6-DC\"\u003eSOL-3.0-MINI-S6-DC\u003c\/a\u003e)\u003c\/div\u003e \u003cdiv class=\"bulkPackText\"\u003e Other available sizes are: \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-3.0-MINI-S6-DC-10\"\u003eSolis 3.0kW Mini S6 Single Tracker with DC isolator (Pack of 10)\u003c\/a\u003e \u003c\/div\u003e \u003cdiv class=\"bulkPackTextItem\"\u003e \u003ca href=\"\/products\/SOL-3.0-MINI-S6-DC-24\"\u003eSolis 3.0kW Mini S6 Single Tracker with DC isolator (1x Pallet)\u003c\/a\u003e \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eOverview\u003c\/div\u003e\n    \u003ch2\u003eAbout the Solis S6 Mini\u003c\/h2\u003e\n    \u003cp\u003eMost UK roofs that get turned down for solar are turned down for the same reason: one usable pitch, room for six or eight panels, and a quote built around an inverter designed for twice that array. The Solis S6 Mini exists for exactly those roofs. It is a single-MPPT, single-phase string inverter in seven power steps from 0.7 kW to 3.6 kW, so the inverter can be sized to the array rather than the array sized to the inverter.\u003c\/p\u003e\n    \u003cp\u003eThe engineering that matters here is at the bottom of the power curve, not the top. A 60 V start-up voltage on the smaller models and an MPPT window that opens at 50 V means the inverter is awake and exporting on a dull February morning, when a higher-threshold unit is still sitting at zero. Over a UK year that low-light behaviour is worth more than a tenth of a percent on peak efficiency.\u003c\/p\u003e\n    \u003cp\u003eIt is also genuinely small — 310 × 373 × 160 mm and 7.4 kg — which matters more than the spec sheet suggests. It goes on a garage wall, in a loft, or in a cupboard without a second pair of hands, and it is rated IP66 so it can equally live outside.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-highlight\"\u003e\n      \u003cdiv class=\"cr-eyebrow\"\u003eFor the installer\u003c\/div\u003e\n      \u003ch2\u003eString design, certification and what is in the box\u003c\/h2\u003e\n      \u003cp\u003eThe details that decide whether this unit suits the job:\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003eIntegrated AFCI (activation required) and an optional integrated DC switch — the SKUs we stock are the DC-isolator versions, so there is no separate isolator to buy, mount and wire.\u003c\/li\u003e\n        \u003cli\u003eG98 and G99 certified, with EN 50549-1 and VDE-AR-N 4105 on the same sheet, so the DNO paperwork is straightforward on either route.\u003c\/li\u003e\n        \u003cli\u003eIntegrated Export Power Manager, so an export limit can be set without an external EPM box.\u003c\/li\u003e\n        \u003cli\u003eRS485 as standard with Wi-Fi and GPRS dataloggers optional, all reporting into SolisCloud.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-dark\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eApplications\u003c\/div\u003e\n    \u003ch2\u003eWhere this inverter earns its place\u003c\/h2\u003e\n    \u003cp\u003eThe S6 Mini is specified most often for these jobs.\u003c\/p\u003e\n    \u003cdiv class=\"cr-appgrid\"\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSmall domestic roofs\u003c\/strong\u003e\u003cspan\u003eSix to twelve panels on one pitch, where a larger inverter would spend most of the year loafing.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSingle-orientation arrays\u003c\/strong\u003e\u003cspan\u003eOne MPPT is the right answer when every panel faces the same way and nothing shades them.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eSystem top-ups\u003c\/strong\u003e\u003cspan\u003eAdding a second small array on its own inverter rather than re-engineering an existing string.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eGarden rooms and outbuildings\u003c\/strong\u003e\u003cspan\u003eIP66 and 7.4 kg means it mounts where the array is, not where the house is.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eRental and social housing\u003c\/strong\u003e\u003cspan\u003eLow capital cost per installed kWp on the roof sizes that dominate the housing stock.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-app\"\u003e\n\u003cstrong\u003eLandlord and portfolio rollouts\u003c\/strong\u003e\u003cspan\u003eBought by the pallet, the per-unit cost drops again.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBattery and storage\u003c\/div\u003e\n    \u003ch2\u003eCan I add a battery to this?\u003c\/h2\u003e\n\u003cp\u003eThis is a \u003cstrong\u003egrid-tied PV inverter\u003c\/strong\u003e. It converts solar DC into AC for the property and the grid, and it has no battery port. That is not a shortcoming — it is the right architecture for a system without storage, and it is why it costs what it does.\u003c\/p\u003e\n\u003cp\u003eIf storage is on the roadmap, you have two routes. Add an AC-coupled battery system alongside this inverter later, which works with any PV inverter and needs no change to what is already installed. Or choose a hybrid inverter now and pay for a battery port you will use in a year or two. We are happy to talk that trade-off through before you order.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eBefore you order\u003c\/div\u003e\n    \u003ch2\u003eThings worth knowing about this listing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-warn\"\u003eThese notes come from us and from the manufacturer, and they are the ones that most often cause a problem after delivery:\n      \u003cul\u003e\n        \u003cli\u003eThis inverter does not include a data logger or CT. For a single-inverter installation use CT SOL-CT-100A-10M; for more than one inverter use the EPM1. The CT requires a separate data logger. These items are sold separately.\u003c\/li\u003e\n        \u003cli\u003eThis product must be installed by a qualified electrician or technician. All installations must adhere to local wiring regulations and standards. ClearRay Solar will not be held liable for any product malfunctions as a result of incorrectly installed systems.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eTechnical specification\u003c\/div\u003e\n    \u003ch2\u003eSolis S6-GR1P3K-M technical data\u003c\/h2\u003e\n    \u003cdiv class=\"cr-table\"\u003e\n      \u003cspan class=\"cr-subhead\"\u003eThis model\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRecommended maximum PV power\u003c\/span\u003e\u003cstrong\u003e4.5 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum DC input voltage\u003c\/span\u003e\u003cstrong\u003e600 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated DC voltage\u003c\/span\u003e\u003cstrong\u003e330 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eStart-up voltage\u003c\/span\u003e\u003cstrong\u003e90 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMPPT voltage range\u003c\/span\u003e\u003cstrong\u003e80 – 500 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input current\u003c\/span\u003e\u003cstrong\u003e19 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum short circuit current\u003c\/span\u003e\u003cstrong\u003e30 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum input strings\u003c\/span\u003e\u003cstrong\u003e2\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eOutput and performance\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output power\u003c\/span\u003e\u003cstrong\u003e3 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum apparent output power\u003c\/span\u003e\u003cstrong\u003e3.3 kVA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum active output power\u003c\/span\u003e\u003cstrong\u003e3.3 kW\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated output current\u003c\/span\u003e\u003cstrong\u003e13.6 A \/ 13 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum output current\u003c\/span\u003e\u003cstrong\u003e15.7 A\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum efficiency\u003c\/span\u003e\u003cstrong\u003e97.3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eEuropean weighted efficiency\u003c\/span\u003e\u003cstrong\u003e96.8 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWeight\u003c\/span\u003e\u003cstrong\u003e7.7 kg\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCommon to the range\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eNumber of MPP trackers\u003c\/span\u003e\u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid voltage\u003c\/span\u003e\u003cstrong\u003e1\/N\/PE, 220 V \/ 230 V\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRated grid frequency\u003c\/span\u003e\u003cstrong\u003e50 Hz \/ 60 Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003ePower factor\u003c\/span\u003e\u003cstrong\u003e\u0026gt;0.99, adjustable 0.8 leading to 0.8 lagging\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTHDi\u003c\/span\u003e\u003cstrong\u003e\u0026lt;3 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eTopology\u003c\/span\u003e\u003cstrong\u003eTransformerless\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSelf consumption at night\u003c\/span\u003e\u003cstrong\u003e\u0026lt;1 W\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003cstrong\u003e310 × 373 × 160 mm\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eOperating ambient temperature\u003c\/span\u003e\u003cstrong\u003e−25 °C to +60 °C\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eRelative humidity\u003c\/span\u003e\u003cstrong\u003e0 – 100 %\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIngress protection\u003c\/span\u003e\u003cstrong\u003eIP66\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCooling\u003c\/span\u003e\u003cstrong\u003eNatural convection\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eMaximum operating altitude\u003c\/span\u003e\u003cstrong\u003e4,000 m\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC connection\u003c\/span\u003e\u003cstrong\u003eMC4 connector\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eAC connection\u003c\/span\u003e\u003cstrong\u003eQuick connection plug\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDisplay\u003c\/span\u003e\u003cstrong\u003eLCD\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eCommunication\u003c\/span\u003e\u003cstrong\u003eRS485; Wi-Fi and GPRS optional\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eDC reverse polarity protection\u003c\/span\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eIntegrated AFCI (DC arc fault)\u003c\/span\u003e\u003cstrong\u003eYes, activation required\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cspan class=\"cr-subhead\"\u003eCompliance and warranty\u003c\/span\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eGrid connection standards\u003c\/span\u003e\u003cstrong\u003eG98 or G99, VDE-AR-N 4105 \/ VDE V 0124, EN 50549-1, VDE 0126 \/ UTE C 15 \/ VFR:2019, RD 1699 \/ RD 244 \/ UNE 206006 \/ UNE 206007-1, CEI 0-21, C10\/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSafety and EMC\u003c\/span\u003e\u003cstrong\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-1\/-2\/-3\/-4\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eWarranty\u003c\/span\u003e\u003cstrong\u003e5 years standard, extendable to 10, 15 or 20 years\u003c\/strong\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-row\"\u003e\n\u003cspan\u003eSpecification source\u003c\/span\u003e\u003cstrong\u003eData Sheet S6-GR1P(0.7-3.6)K-M - EN\u003c\/strong\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eGoes with this\u003c\/div\u003e\n    \u003ch2\u003eOrdered with this inverter more often than anything else\u003c\/h2\u003e\n    \u003cp\u003eAn inverter on its own rarely completes the job. These are the parts our customers add most often:\u003c\/p\u003e\n    \u003cdiv class=\"cr-links\"\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-3-0-mini-s6-dc\"\u003eS6 Mini 3kW 1MPPT 1Ph Inverter - with DC isolator\u003c\/a\u003e\u003cspan\u003eThe same inverter as a single unit.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-s2-wl-st-usb\"\u003eSolis Data Logging Stick - Wi-Fi \u0026amp; LAN USB\u003c\/a\u003e\u003cspan\u003eThe datalogger. Not in the box, and needed for SolisCloud monitoring.\u003c\/span\u003e\n\u003c\/div\u003e\n      \u003cdiv class=\"cr-link\"\u003e\n\u003ca href=\"\/products\/sol-ct-100a-10m\"\u003eCurrent Transformer for Solis 4G, 5G and S6 range 100A 10m\u003c\/a\u003e\u003cspan\u003eThe CT for export limitation and consumption monitoring within 10 m of the supply.\u003c\/span\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section cr-faq\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eFrequently asked questions\u003c\/div\u003e\n    \u003ch2\u003eQuestions we get asked about this inverter\u003c\/h2\u003e\n    \u003cdetails\u003e\u003csummary\u003eWill this work on a north-east or north-west facing roof?\u003c\/summary\u003e\u003cp\u003eYes, and the low start-up voltage is why. It will not turn a poor roof into a good one, but it will harvest the shoulders of the day that a higher-threshold inverter misses.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eOne MPPT — does that limit me?\u003c\/summary\u003e\u003cp\u003eIt limits you to one orientation and one string. If your array is split across two pitches, or is partly shaded, choose the dual-MPPT S6 range instead and put each pitch on its own tracker.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eDoes it come with a DC isolator?\u003c\/summary\u003e\u003cp\u003eThe models we stock do, integrated in the unit. That removes a separate enclosure from the install and a component from the bill.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eIs it G99 approved?\u003c\/summary\u003e\u003cp\u003eYes. G98 and G99 certificates are attached to this listing in the Documents tab, along with the EN 50549-1 declaration.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eCan I add a battery later?\u003c\/summary\u003e\u003cp\u003eNot to this inverter — it is grid-tied only, with no battery port. You would either add an AC-coupled battery system alongside it, or replace it with a hybrid. We are happy to talk that through before you buy.\u003c\/p\u003e\u003c\/details\u003e\n    \u003cdetails\u003e\u003csummary\u003eWhat warranty comes with it?\u003c\/summary\u003e\u003cp\u003eFive years as standard, extendable to 10, 15 or 20 years. Registration terms are in the Solis warranty document attached to this listing.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"cr-section\"\u003e\n    \u003cdiv class=\"cr-eyebrow\"\u003eClearRay Solar\u003c\/div\u003e\n    \u003ch2\u003eDocuments, advice and trade pricing\u003c\/h2\u003e\n    \u003cdiv class=\"cr-seo\"\u003e\u003cp\u003eEvery datasheet, certificate, installation manual and warranty document we hold for this product is in the Documents tab below. See the rest of our \u003ca href=\"\/collections\/inverters\"\u003einverter range\u003c\/a\u003e and our \u003ca href=\"\/collections\/panels\"\u003esolar panels\u003c\/a\u003e, or email our sales team at \u003ca href=\"mailto:sales@clearraysolar.com\"\u003esales@clearraysolar.com\u003c\/a\u003e if you would like us to check a string design or a compatibility question before you order.\u003c\/p\u003e\u003c\/div\u003e\n  \u003c\/section\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\/* ClearRay product description layout. Scoped entirely to .cr-pdp. *\/\n.cr-pdp { color: inherit; font-family: inherit; line-height: 1.6; max-width: 1200px; margin: 0 auto; }\n.cr-pdp *, .cr-pdp *::before, .cr-pdp *::after { box-sizing: border-box; }\n\n.cr-eyebrow { font-size: 11px; font-weight: 800; letter-spacing: 1.4px; color: #2d7ff9; margin-bottom: 7px; text-transform: uppercase; }\n\n.cr-hero { padding: 5px 0 20px; }\n.cr-hero h2 { font-size: clamp(25px, 3vw, 34px); line-height: 1.18; letter-spacing: -0.6px; margin: 0 0 12px; }\n.cr-hero .cr-sub { font-size: 16px; line-height: 1.5; font-weight: 600; max-width: 900px; margin: 0 0 10px; opacity: 0.9; }\n.cr-hero p:not(.cr-sub) { max-width: 950px; margin: 0 0 10px; opacity: 0.76; }\n\n.cr-specgrid { display: grid; grid-template-columns: repeat(4, 1fr); gap: 10px; margin: 20px 0 35px; }\n.cr-speccard { padding: 15px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.025); border-radius: 10px; transition: all 0.2s ease; }\n.cr-speccard:hover { transform: translateY(-2px); border-color: rgba(45,127,249,0.3); }\n.cr-speccard .cr-lbl { font-size: 10px; font-weight: 700; text-transform: uppercase; letter-spacing: 0.6px; opacity: 0.55; margin-bottom: 3px; }\n.cr-speccard strong { display: block; font-size: 18px; line-height: 1.2; margin-bottom: 3px; }\n.cr-speccard span { display: block; font-size: 11px; opacity: 0.6; }\n\n.cr-section { margin: 38px 0; }\n.cr-section h2 { font-size: 23px; line-height: 1.25; letter-spacing: -0.3px; margin: 0 0 12px; }\n.cr-section h3 { line-height: 1.3; }\n.cr-section p { margin: 0 0 12px; opacity: 0.76; }\n\n.cr-benefits { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-benefit { padding: 17px; border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; background: rgba(0,0,0,0.02); border-left: 3px solid #2d7ff9; }\n.cr-benefit h3 { font-size: 14px; margin: 0 0 5px; }\n.cr-benefit p { font-size: 12px; margin: 0; }\n\n.cr-dark { padding: 28px; border-radius: 14px; background: #101828; color: #fff; }\n.cr-dark p { opacity: 0.75; }\n.cr-dark .cr-eyebrow { color: #67a9ff; }\n.cr-appgrid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 10px; margin-top: 20px; }\n.cr-app { padding: 16px; border: 1px solid rgba(255,255,255,0.12); border-radius: 10px; background: rgba(255,255,255,0.045); }\n.cr-app strong { display: block; font-size: 13px; margin-bottom: 4px; }\n.cr-app span { display: block; font-size: 11px; opacity: 0.65; }\n\n.cr-table { border: 1px solid rgba(0,0,0,0.08); border-radius: 10px; overflow: hidden; margin-top: 18px; }\n.cr-row { display: grid; grid-template-columns: 1fr 1fr; padding: 11px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); font-size: 12px; gap: 15px; }\n.cr-row:last-child { border-bottom: 0; }\n.cr-row:nth-child(even) { background: rgba(0,0,0,0.018); }\n.cr-row span { opacity: 0.62; }\n.cr-row strong { text-align: right; font-weight: 600; }\n.cr-subhead { font-size: 10px; font-weight: 800; text-transform: uppercase; letter-spacing: 0.5px; background: rgba(0,0,0,0.035); opacity: 0.7; display: block; padding: 9px 16px; border-bottom: 1px solid rgba(0,0,0,0.06); }\n\n.cr-note { font-size: 11px !important; opacity: 0.58 !important; margin-top: 10px !important; }\n\n.cr-highlight { padding: 22px; border-radius: 12px; border: 1px solid rgba(45,127,249,0.2); background: rgba(45,127,249,0.05); }\n.cr-highlight ul { margin: 10px 0 0; padding-left: 18px; }\n.cr-highlight li { font-size: 12.5px; margin-bottom: 7px; opacity: 0.82; }\n\n.cr-warn { padding: 15px; margin-top: 15px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; }\n\/* Supplier notices arrive as \u003cdiv class=\"warning\"\u003e and are preserved verbatim,\n   stray tags and all. They are styled where they stand rather than wrapped, so\n   nothing this page emits can be unbalanced by markup it does not control. *\/\n.cr-pdp .warning { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(255,180,0,0.07); border: 1px solid rgba(255,180,0,0.25); font-size: 12.5px; line-height: 1.55; }\n.cr-pdp .warning:last-child { margin-bottom: 0; }\n.cr-pdp .warning b, .cr-pdp .warning strong { font-weight: 700; }\n.cr-pdp .AlertText { padding: 14px 16px; margin: 0 0 10px; border-radius: 9px; background: rgba(45,127,249,0.06); border: 1px solid rgba(45,127,249,0.22); font-size: 12.5px; }\n.cr-pdp .AlertText h2 { font-size: 14px; margin: 0 0 6px; }\n.cr-pdp .prod_composite, .cr-pdp .bulkPackText, .cr-pdp .bulkPackTextItem { font-size: 13px; }\n.cr-warn ul { margin: 8px 0 0; padding-left: 18px; }\n.cr-warn li { margin-bottom: 6px; }\n\n.cr-links { display: grid; grid-template-columns: repeat(3, 1fr); gap: 11px; margin-top: 18px; }\n.cr-link { padding: 15px; border-radius: 10px; border: 1px solid rgba(0,0,0,0.08); background: rgba(0,0,0,0.02); }\n.cr-link a { font-size: 13px; font-weight: 700; text-decoration: none; }\n.cr-link span { display: block; font-size: 11px; opacity: 0.62; margin-top: 4px; }\n\n.cr-faq details { border-bottom: 1px solid rgba(0,0,0,0.08); padding: 14px 0; }\n.cr-faq summary { cursor: pointer; font-weight: 700; font-size: 14px; list-style: none; position: relative; padding-right: 25px; }\n.cr-faq summary::-webkit-details-marker { display: none; }\n.cr-faq summary::after { content: \"+\"; position: absolute; right: 0; top: -2px; font-size: 18px; font-weight: 400; opacity: 0.5; }\n.cr-faq details[open] summary::after { content: \"\\2212\"; }\n.cr-faq details p { padding-top: 8px; font-size: 12.5px; margin: 0; }\n\n.cr-seo p { max-width: 1000px; }\n\n@media (max-width: 1000px) {\n  .cr-specgrid { grid-template-columns: repeat(2, 1fr); }\n  .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: repeat(2, 1fr); }\n}\n@media (max-width: 650px) {\n  .cr-hero h2 { font-size: 25px; }\n  .cr-specgrid, .cr-benefits, .cr-appgrid, .cr-links { grid-template-columns: 1fr; }\n  .cr-dark { padding: 22px 16px; border-radius: 11px; }\n  .cr-row { grid-template-columns: 1fr; gap: 2px; }\n  .cr-row strong { text-align: left; }\n  .cr-highlight { padding: 19px 16px; }\n}\n\u003c\/style\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":57440934429004,"sku":"SOL-3.0-MINI-S6-DC-5","price":1007.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1048\/7742\/4972\/files\/SOL-3.0-MINI-S6-DC-5.jpg?v=1778196296"}],"url":"https:\/\/clearraysolar.com\/collections\/bulk-products.oembed?page=2","provider":"ClearRay Solar","version":"1.0","type":"link"}